324 resultados para gravimetric inversion
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
The multi-layers feedforward neural network is used for inversion of material constants of fluid-saturated porous media. The direct analysis of fluid-saturated porous media is carried out with the boundary element method. The dynamic displacement responses obtained from direct analysis for prescribed material parameters constitute the sample sets training neural network. By virtue of the effective L-M training algorithm and the Tikhonov regularization method as well as the GCV method for an appropriate selection of regularization parameter, the inverse mapping from dynamic displacement responses to material constants is performed. Numerical examples demonstrate the validity of the neural network method.
Resumo:
Based on the homotopy mapping, a globally convergent method of parameter inversion for non-equilibrium convection-dispersion equations (CDEs) is developed. Moreover, in order to further improve the computational efficiency of the algorithm, a properly smooth function, which is derived from the sigmoid function, is employed to update the homotopy parameter during iteration. Numerical results show the feature of global convergence and high performance of this method. In addition, even the measurement quantities are heavily contaminated by noises, and a good solution can be found.
Resumo:
Finite-fringe interferograms produced for axisymmetric shock wave flows are analyzed by Fourier transform fringe analysis and an Abel inversion method to produce density field data for the validation of numerical models. For the Abel inversion process, we use basis functions to model phase data from axially-symmetric shock wave structure. Steady and unsteady flow problems are studied, and compared with numerical simulations. Good agreement between theoretical and experimental results is obtained when one set of basis functions is used during the inversion process, but the shock front is smeared when another is used. This is because each function in the second set of basis functions is infinitely differentiable, making them poorly-suited to the modelling of a step function as is required in the representation of a shock wave.
Resumo:
We analyse the physical origin of population inversion via continuous wave two-colour coherent excitation in three-level systems by dressing the inverted transition. Two different mechanisms are identified as being responsible for the population inversion. For V-configured systems and cascade (E) configured systems with inversion on the lower transition, the responsible mechanism is the selective trapping of dressed states, and the population inversion approaches the ideal value of 1. For Lambda-configured systems and Xi-configured systems with inversion on the upper transition, population inversion is based on the selective excitation of dressed states, with the population inversion tending towards 0.5. As the essential difference between these two mechanisms, the selective trapping of dressed states occurs in systems with strong decay into dressed states while the selective excitation appears in systems with strong decay out of dressed states.
Resumo:
The transient evolution processes and steady outputs of continuous wave lasing without inversion (LWI) and self-pulsing LWI in a resonant open V type three-level system are studied. It was found that the two kinds of LWI have some obvious differences not only from the steady outputs but also from the transient evolution processes. The effects of the unsaturated gain coefficient, cavity loss coefficient, ratio of the atomic injection rates and atomic exit rate on the transient evolution processes and steady outputs are discussed.
Lasing without or with inversion in an open four-level system with a phase-fluctuation driving field
Resumo:
The effect of exit rate and the ratio of atomic injection rate on gain behaviour has been investigated, and the effects of phase fluctuation on absorption, dispersion and population difference in an open four-level system have been analysed by using numerical simulation from the steady linear, analytical solution. The variation of the linewidth, Rabi frequency of the driving field, the exit rate or the ratio of atomic injection rate can change the lasing properties in the open system. The presence of finite linewidth due to driving-field phase fluctuation prevents the open four-level atomic system from obtaining a high refractive index along with zero absorption.
Resumo:
Sideband manipulation of population inversion in a three-level A atomic configuration is investigated theoretically. Compared with the case of a nearly monochromatic field, a population inversion between an excited state and a ground state has been found in a wide sideband intensity range by increasing the difference in frequency between three components. Furthermore, the population inversion can be controlled by the sum of the relative phases of the sideband components of the trichromatic pump field with respective to the phase of the central component. Changing the sum phase from 0 to pi, the population inversion between the excited state and the ground state can increase within nearly half of the sideband intensity range. At the same time, the sideband intensity range that corresponds to the system exhibiting inversion rho(00) > rho 11 also becomes wider evidently.
Resumo:
The effects of vacuum-induced coherence (VIC) on the properties of the absorption and gain of the probe field in an equispaced three-level ladder atomic system are investigated. It is found that lasing without inversion (LWI) is remarkably enhanced due to the effect of VIC in the case of the small incoherent pump rate.
Resumo:
A reversible electrochromic effect accompanying domain-inversion during the electrical poling process in LiNbO3: Ru: Fe crystals at room temperature has been observed. In electrode area, both electrochromism and domain-inversion occur alternately, and electrochromism is also reversible during back-switch poling, which is experimentally verified and whose mechanism is briefly explained using a microstructure ferroelectric model. In addition, because of the enhancing elcctrochromic effect, different from the undoped LiNbO3 crystals, the coercive riled (21.0 kV/mm or so) measured in LiNbO3: Ru: Fe is lower than its breakdown field, thus providing a possible new technique for realizing the domain-inversion by constant electric field rather than a pulsed one.
Resumo:
Electrochromic phenomena accompanying the ferroelectric domain inversion in congruent RuO2-doped z-cut LiNbO3 crystals at room temperature are observed in experiments. During the electric poling process, the electrochromism accompanies the ferroelectric domain inversion simultaneously in the same poled area. The electrochromism is completely reversible when the domain is inverted from the reverse direction. The influences of electric field and annealing conditions on domain inversion and electrochromism are also discussed. We propose the reasonable assumption that charge redistribution within the crystal structure caused by domain inversion is the source for electrochemically oxidation and reduction of Ru ion to produce the electrochromic effect. (c) 2005 Optical Society of America.
Resumo:
A reversible electrochromic effect during the electrical poling process in LiNbO3:Ru:Fe crystals at room temperature is observed. In electrode area, both electrochromism and domain-inversion occur mutually and electrochromism is reversible during back-switch poling, which are experimentally verified, and a microstructure model to explain the mechanism is proposed. In addition, different from the undoped LiNbO3 crystals, the breakdown field (> 25.0 kV/mm) is higher than the coercive (21.0 kV/mm) measured in LiNbO3:Ru:Fe, which proves a possible new technique to realize domain-inversion by constant electric field rather than pulsed one. (c) 2005 American Institute of Physics.
Resumo:
We quantitatively study the domain inversion in a RuO2:LiNbO3 crystal wafer by the digital holographic interferometry. The crystal wafer is placed into one arm of a Mach-Zehnder-type interferometer to record a series of holograms. Making use of the angular spectrum backward propagation algorithm, we reconstruct the optical wave field in the crystal plane. The extracted phase difference from the reconstructed optical wave field is a well linear function of the applied external voltage. We deduce that the linear electro-optic coefficient of the detected RuO2:LiNbO3 crystal sample is 9.1x10(-12) m/V. An unexpected phase contrast at the antiparallel domain wall is observed and the influence of the applied external voltage on it is studied in detail. Also the built-in internal field is quantitatively measured as 0.72 kV/mm. (c) 2006 American Institute of Physics.
Resumo:
A laser beam at wavelength 647 nm is focused on a sample of 5 mol% MgO-doped lithium niobate crystal for domain inversion by a conventional external electric field. In this case, a reduction of 36% in the electric field required for domain nucleation (nucleation field) is observed. To the best of our knowledge, it is the longest wavelength reported for laser-induced domain inversion. This extends the spectrum of laser inducing, and the experimental results are helpful to understand the nucleation dynamics under laser illumination. The dependence of nucleation fields on intensities of laser beams is analysed in experiments.
Resumo:
The application of digital holographic interferometry on the quantitative measurement of the domain inversion in a RuO2: LiNbO3 crystal wafer is presented. The recorded holograms are reconstructed by the angular spectrum method. From the reconstructed phase distribution we can clearly observe the boundary between the inverted and un-inverted domain regions. Comparisons with the results reconstructed by use of the Fresnel transform method are given. Factors that influence the measurement include the spectrum filter size and the spectrum movement are discussed. The spectrum filter size has an effect on the measurement of the details. Although the spectrum movement affects every single reconstructed image, it has no influence on the final measurement.