49 resultados para delay-line position sensitive detector

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multi-hit 3-layer delay-line anode (Hexanode) has an increased ability to detect multi-hit events in a collision experiment. Coupled with a pair of micro-channel plates, it can provide position information of the particles even if the particles arrive at the same time or within small time dwell. But it suffers from some ambiguous outputs and signal losses due to timing order and triggering thresholds etc. We have developed a signal reconstruction program to correct those events. After the program correction, the dead time only exists when 2 paxticles arrive at the same time and the same position within a much smaller range. With the combination of Hexanode and the program, the experimental efficiencies will be greatly improved in near threshold double ionization on He collisions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new non-linear comparison method of charge-division readout scheme is conceived and the first design of a multi-hit two-dimensional position-sensitive energy spectrum Si(Au) surface barrier detector with a continuous sensitive area is proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

针对高流强粒子束与绝缘毛细管相互作用的特点,设计制作了一套64通道一维位置灵敏电流分布探测器及其配套的数据获取系统,该探测器可分辨最小直径为1mm的束斑,通过数据获取系统可实现可视化自动数据采集。用2nA和200—2000eV电子对探测器进行了定标,并用10μA和2000eV的电子束穿越锥形毛细管后的出射电子,对探测器及数据获取系统进行测试,获得了出射粒子的位置分布谱及能量信息。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A prototype of time-of-flight positron emission computed tomography (TOF-PET) has been developed for acquiring the coincident detection of 511 keV gamma-rays produced from positron annihilation. It consists of two 80.5 mmx80.5 mm LYSO scintillator arrays (composed of 35 x35 pixel finger crystals) with the position sensitive photomultiplier tubes R2487 as the readout. Each array is composed of 2 mm x2 mm x 15 mm finger crystals and the average pixel pitch is 2.30 mm. The measured results indicate that the TOF information has the potential to significantly enhance the image quality by improving the noise variance in the image reconstruction. The best spatial resolution (FWHM) of the prototype for the pairs of 511 keV gamma-rays is 1.98 mm and 2.16 mm in the x and y directions, respectively, which are smaller than the average pixel pitch of 2.30 mm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

气体探测器有成本低廉、制备简单、性能可靠和方便使用等特点。研制了一种5层板结构的延迟线平行板雪崩电离室(PPAC),用于兰州放射性束流线(RIBLL)上开展的实验。在57.6MeV/u的6He束流条件下测试了这种探测器对高能轻粒子的适用性,得到了位置分辨为1.8mm(FWHM),时间分辨为2.6ns,以及可靠的探测效率。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose an optical apparatus enabling the measurement of spherical power, cylindrical power, and optical center coordinates of ophthalmic lenses. The main advantage of this new focimeter is to provide a full bidimensional mapping of the characteristics of ophthalmic glasses. This is made possible thanks to the use of a large-area and high-resolution position-sensitive detector. We describe the measurement principle and present some typical mappings, particularly for progressive lenses. We then discuss the advantages in terms of speed and versatility of such a focimeter for the measurement of complex lens mappings. (C) 2002 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using two prisms for measurement of small dynamic angles is proposed in which the measurement is based on a simple tangent equation and a phase-modulating interferometer with a laser diode to measure dynamic optical path differences with higher accuracy. Owing to the simple tangent equation, the symmetry requirement on the two prisms in the optical configuration is eliminated, and easy measurement of the separations between two parallel beams with a position-sensitive detector is achieved. Small-dynamic-angle measurements are experimentally demonstrated with high accuracy. (C) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出一种基于平行平板干涉仪的改进型角度测量方法。为了实现较大的偏转角度测量,该平行平板干涉仪引入了一位置探测系统。平面反射镜的引入提高了角度测量的分辨率。实验验证了可在近3度的范围内实现被测偏转角度的高精度测量。并且作为一位相调制型干涉仪,其小角位移测量实验的重复精度可达5.5×10^(-8)rad。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using two prisms for measurement of small dynamic angles is proposed in which the measurement is based on a simple tangent equation and a phase-modulating interferometer with a laser diode to measure dynamic optical path differences with higher accuracy. Owing to the simple tangent equation, the symmetry requirement on the two prisms in the optical configuration is eliminated, and easy measurement of the separations between two parallel beams with a position-sensitive detector is achieved. Small-dynamic-angle measurements are experimentally demonstrated with high accuracy. (C) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A parallel plate interferometer with a reflecting mirror for measuring angular displacement is proposed. A deflection angle of a beam caused by an angular displacement is amplified by use of a reflecting mirror to increase the optical path difference (OPD) in the plane-parallel plate, which provides high sensitivity of the phase measurement. Detection of light transmitted through the plane-parallel plate with a position sensitive detector (PSD) enables high accurate measurement of the initial angle of incidence to the plane-parallel plate with insensitivity to stray light. The improved parallel plate interferometer achieves a measurement repeatability of 10(-8) rad. (C) 2007 The Optical Society of Japan.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

在一种已有的角位移干涉测量技术的基础上,提出一种改进的角位移测量方法。通过选择合适的初始入射角,使从平板前后表面反射的两光束实现剪切干涉。采用一维位置探测器测量光束经透镜会聚后在探测器光敏面上的光点偏移量。根据干涉信号的相位和光点偏移量可以计算出被测物体的角位移。在该测量方案中,引入的一平面反射镜与被测物体的反射面形成光程差放大系统,提高了角位移测量灵敏度。分析了初始入射角对剪切比的影响,并讨论了基于该方案的角位移测量精度。实验结果表明,基于该技术的角位移重复测量精度达到10-8 rad数量级。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the experiment of nuclear reaction, it is important to measure the mass, charge, energy and emitted direction of particles. For multiparameter measurement, we must use a detector or a group of detectors which can give the time, energy, and position information. The Large Area position sensitive Ionization Chamber(LAIC) is one of the eight experiment terminals of HIRFL. It is built for researching nuclear reactions from low energy to intermediate energy. It is an excellent equipment for energy measurements and atomic number identification of emitted fragments in this energy region. It is also designed to give the time and position information of the emitted fragments by itself. Obviously, an IC can not supply a good timing signal. Moreover, the mechanical installation is different from the original design by some other reasons. In this case, it is not enough to obtain the correct direction information of the emitted fragments. To obtain good timing signals and the correct direction information, some modifications must be made. It is well known that a PPAC can give us excellent timing signals. It also can be easily built as a position sensitive detector. For this reason, a specially designed PPAC is installed in the entrance of the LAIC. For the different purposes, two types of PPACs were designed and tested. Both are OCTPSACs (OCTunit one dimension Position Sensitive Avalanche Counter). In this paper, both OCTPSACs will be introduced. Based on the requirements of the LAIC, the OCTPSACs consist of eight position sensitive PPACs. Each PPAC has an anode and a cathode. In both cases, the sizes are same. But different type of cathodes are used. In one type of OCTPSAC, its cathode is made of wire plane. It consists of gold-plated tungsten wires with the diameter of 20μm, spaced 0.5 mm apart from each other. The anode is a mylar foil which was evaporated by gold layer with the thickness of 50μg/cm~2 mounted on a printed plate in the shape of rectangle. the thickness of mylar foil is 1.5μm. The gap between anode and cathode is 3mm. The performance of the OCTPSAC has been tested by using a ~(252)Cf source in flowing isobutylene gas at the pressure of 3.4mb. The intrinsic time resolution of 289ps and position resolution of 2 mm have been obtained. In another type of OCTPSAC, the cathode is made of mylar foil, which is composed of gold strip by vacuume evaporation method with a special mask on the mylar foil. The thickness and the width of the gold strip is 50μg/cm~2 and 1.7mm. The strips are spaced 0.3 mm apart from each other. The anode is the same as the former type. We have obtained the time resolution of 296ps and position resolution of 2mm by using ~(241)Am-a source when the gas pressure is 6 mb and high voltage is 600V. The working gas is heptane

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PSD是一种高分辨率、实时性好的光电位置敏感器件,因而具有广泛应用的前景.但在光照度变化条件下,输出信号存在非线性飘移,因而影响了作为位置检测传感器的检测精度,尤其在3D测量时适用性受到了限制.针对这个问题,提出了一种PSD位置传感器的非线性误差补偿方法.该方法针对目标的空间距离变化所产生的PSD输出非线性飘移,采用归一化模型进行误差修正,很大程度上改进了PSD的输出一致性,使基于PSD的3D测量系统性能得以提高.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigate the controllable negative and positive group delay in transmission through a single quantum well at the finite longitudinal magnetic fields. It is shown that the magneto-coupling effect between the longitudinal motion component and the transverse Landau orbits plays an important role in the group delay. The group delay depends not only on the width of potential well and the incident energy, but also on the magnetic-field strengthen and the Landau quantum number. The results show that the group delay can be changed from positive to negative by the modulation of the magnetic field. These interesting phenomena may lead to the tunable quantum mechanical delay line. (c) 2007 Elsevier B.V. All rights reserved.