61 resultados para data acquisition system

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

针对高流强粒子束与绝缘毛细管相互作用的特点,设计制作了一套64通道一维位置灵敏电流分布探测器及其配套的数据获取系统,该探测器可分辨最小直径为1mm的束斑,通过数据获取系统可实现可视化自动数据采集。用2nA和200—2000eV电子对探测器进行了定标,并用10μA和2000eV的电子束穿越锥形毛细管后的出射电子,对探测器及数据获取系统进行测试,获得了出射粒子的位置分布谱及能量信息。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本文介绍了一种用于载人潜水器的导航传感器的数据采集及信息融合技术。航行控制计算机通过基于工业以太网的数据通信系统对各传感器进行数据采集,采用卡尔曼滤波器完成对各传感器数据信息的融合,以便提高数据的精度和控制系统的性能,并将结果送给监控计算机,用于载人潜水器的姿态显示。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Digital Speckle Correlation Method (DSCM) is a useful tool for whole field deformation measurement, and has been applied to analyze the deformation field of rock materials in recent years. In this paper, a Geo-DSCM system is designed and used to analyse the more complicated problems of rock mechanics, such as damage evolution and failure procedure. A weighted correlation equation is proposed to improve the accuracy of displacement measurement on a heterogeneous deformation field. In addition, a data acquisition system is described that can synchronize with the test machine and can capture speckle image at various speeds during experiment. For verification of the Geo-DSCM system, the failure procedure of a borehole rock structure is inspected and the evolution of the deformation localization is analysed. It is shown that the deformation localization generally initializes at the vulnerable area of the rock structure but may develop in a very complicated way.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A multi-channel gated integrator and PXI based data acquisition system have been developed for nuclear detector arrays with hundreds of detector units. The multi-channel gated integrator can be controlled by a programmable Cl controller. The PXI-DAQ system consists of NI PXI-1033 chassis with several PXI-DAQ cards. The system software has a user-friendly GUI which is written in C language using LabWindows/CVI under Windows XP operating system. The performance of the PXI-DAQ system is very reliable and capable of handling event rate up to 40 kHz. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dynamic measurement system was developed by the Institute of Modern Physics (IMP) for the dipole prototype of Rapid Cycle Synchrotron (RCS) of China Spallation Neutron Source (CSNS). The repetition frequency of RCS is 25 Hz. The probe is a moving arc searching-coil, and the data acquisition system is based on the dynamic analysis modular of National Instrument. To get the error of high order harmonics of the field at basic frequency, the hardware integrator is replaced by a high speed ADC with software filter and integrator. A series of harmonic coefficients of field are used to express the varieties of dynamic fields in space and time simultaneously. The measurement system has been tested in Institute of High Energy Physics (IHEP), and the property of the dipole prototype of RCS has been measured. Some measurement results and the repeatability of system are illustrated in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

介绍了一种基于CAN总线的数据采集系统,讨论了该系统应用在海洋平台这类特殊环境下的系统结构和现场节点的具体设计。系统由上位监控机、CAN网卡、智能网桥节点和智能采集节点组成,采用总线方式的网络拓扑结构,构成一种基于CAN总线的分布式监控采集系统。智能节点以AT89S52单片机为微控制器,使用SJA1000作为CAN控制器,可构成上行和下行网络通信波特率分别为500kbps和250kbps的CAN网络。详细分析了该系统的硬件组成,应用层协议和通讯流程。系统已应用于某海上平台的环境载荷的监测,提高了数据传输的可靠性,为平台的安全运行和结构的优化设计提供了科学依据。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A closed aquatic ecosystem (CAES) was developed to stud), the effects of microgravity on the function of closed ecosystems aboard the Chinese retrieved satellite and on the spacecraft SHENZHOU-II. These systems housed a small freshwater snail (Bulinus australianus) and an autotrophic green algae (Chlorella pyrenoidosa). The results of the test on the satellite were that the concentration of algae changed little, but that the snails died during the experiments. We then sought to optimize the function of the control system, the cultural conditions and the data acquisition system and carried out an experiment on the spacecraft SHENZHOU-II. Using various sensors to monitor the CAES, real-time data regarding the operation of the CAES in microgravity was acquired. In addition, all on-board Ig centrifuge was included to identify gravity-related factors. It was found that microgravity is the major factor affecting the operation of the CAES in space. The change in biomass of the primary producer during each day in microgravity was larger than that of the control groups. The mean biomass concentration per day in the microgravity group decreased, but that of the control groups increased for several days and then leveled off. Space effects on the biomass of a primary producer may be a result of microgravity effects leading to increasing metabolic rates of the consumer combined with decreases in photosynthesis. (c) 2007 COSPAR. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A read-out and data acquisition system for the outputs of multi-channel spectroscopy amplifiers is introduced briefly in this paper.The 16-channel gating integrator/multiplexer developed by us and PXI-DAQ card are used to construct this system.A virtual instrument system for displaying,indicating,measuring and recording of output waveform is accomplished by integrating the PC,hardware,software together flexibly based on the Lab Windows/CVI platform in our read-out and data acquisition system.In this system,...中文文摘:简要介绍一个针对多路谱仪放大器的读出与数据采集方法与系统。该系统基于16通道门积分/选通输出电路和通用PXI-DAQ卡构建。利用Lab Windows/CVI平台构建虚拟仪器,灵活地将计算机、硬件、软件结合起来,设计了一个读出与数据采集系统。在该系统中,一个ADC通道可以面对16个谱仪放大器的输出,有效地提高了系统的集成度,降低了数据采集系统的成本。该设计为利用通用型谱仪放大器构建数百参数的信号读出与数据采集系统提供了一种新的方法。通过实验验证,证明该系统具有智能化、可靠性高、实时性强、成本低等优点。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

随着物理实验要求的提高,利用先进的计算机技术来改造现有的物理实验设备具有重要意义。因此,我们设计研制了光谱测量与能级寿命测量数据获取电子学系统。本文全面论述了这一系统的组成结构。本系统由微机进行控制,通过基于Pentium机上工SA总线的接口电路来控制数据采集过程,实现了测量设备的智能化,并具有高速度、高可靠性的特点。配合软件工作可完全实现实验的无人监控。论文第一部分介绍了这个系统开发的背景及意义。第二部分是这个系统的组成和硬件结构、性能。这个系统完成的主要功能是:(1)采集数据并处理;(2)控制外设马达的运动;(3)显示系统的状态。第三部分是调试过程以及针对在调试中出现的各种实际问题提出的解决办法和预防措施。在设计工作完成之后,本系统在兰州近代物理研究所的加速器实验大厅中进行了模拟实验,并采集了部分数据。通过对获取数据的处理,获得了比较满意的结果。在论文的最后一部分中给出了本系统在实际运行后得出的实验结果以及此系统中可待完善之处。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本文介绍我们最新研制的微功耗核谱数据获取系统。目前,该系统基于微型计算机(IBM PC 486)获取,有待进一步发展成单片机获取系统。该系统具有功能强、功耗低、体积小、重量轻以及抗辐射的特点。为了降低功耗,电路设计中尽量使电路简单化,并选用微功耗、抗辐射的MOS场效应管元件。功率消耗单通道小于2.2w,若做成四通道可少于4W。 本系统以脉冲幅度分析方式获取数据,软件采用Turbo C 2.0编写,界面友好,操作方便。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

在偏振耦合测试仪的PCI接口数据采集系统中,现场可编程门阵列(FieldProgramableGateArray)实现了对模/数器件的控制功能,同时完成了与PCI总线控制器间的数据接口功能。应用自顶向下的设计思想,完成了FPGA内部的逻辑设计,并对其逻辑功能进行了仿真验证,给出了FPGA数据采集时的测试时序图。应用FPGA实现的数据采集系统可以检测出偏振耦合检测仪中的微弱干涉光信号。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Under the auspices of the 'knowledge-Innovation Program' of CAS, Institute of Geology and Geophysics has established the Broadband Seismic Laboratory. A new kind of 24-bit high-resolution seismograph DAS24-3B has been designed and manufactured in an effort of developing China's own technology of seismic array. Since these instruments will primarily be used in field operation, there is a need to optimize the system software of data acquisition system (DAS) to enhance its stability, compatibility and maintenance. The design ideas of the system software of DAS24-3B are partly learned from the advanced DAS 72A-08. In this system there are two exclusive communication programs DNAPI-COM1 and DNAPI-LPT1, which are suitable for all standard industrial computers with ECP parallel port and serial port. By these exclusive parallel and serial communication interface the system software is split into three parts, acquisition program, user's control program and graphical display program, which can function well in separate units and can run correctly in whole. The three parts of DAS24-3B's system software possess different functions and advantages. The function of acquisition program is to control the process of seismic data acquisition. DAS24-3B system reduced its power and harddisk read-write disturbance by using the extended memory attached to its CPU, which functions as enlarging the data buffer of system and lessening the times of harddisk read-write operations. Since GPS receiver of DAS is strongly sensitive to the around environment and has the possibility of signal loss the acquisition program has been designed with the ability to automatically trail the GPS locked time. The function of user's controlling program is to configure the system's work environment, to inform the user's commands to DAS, to trail the status of DAS in real-time. The function of graphical display program is to illustrate data in figures, to convert data file into some common formatted file, to split data file in parts and combine data files into one. Both user's control program and graphical display program are API (Application Programming Interface) in window 95/98 system. Both possess the features of clearness and friendship by use of all kind of window controls, which are composed by menu, toolbar, statusbar, dialogue box, message box, edit box, scrollbar, time control, button and so on. Two programs of systemic exception handles are provided to treat the trouble in field. The DAS24-3B DAS has been designed to be easier to use-better ability, more stable and simpler. It has been tested in field and base station and has been proved more suitable for field operation of seismic array than other native instruments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our motherland has large area of maritime space. Searching and developing ocean becomes more and more important. So Ocean Bottom Seismometer (OBS) as an absolutely necessary equipment can be used in many oceanic fields. OBS not only is an important instrument for discovering structure of lithosphere of ocean bottom, but also plays a main role of oceanic geophysical exploration. The paper introduces my relational work. The MCI micro-power broad frequency seismometer was developed independently. Its power dissipation is less than 300mW. It has some merits including miniature volumeN light mass and cheap price. It is an ideal device not only for the collection high-resolution natural seismic data, but also for the fields of seismic sounding and engineering seismology. Many new high technique were applied to develop this instrument including over-sampling A/D converter, high performance 32bit Micro Process Unit and Flash memory with smart-media interface. Base on the achievement, I have accomplished the showpiece of OBS, which is applied to the deepwater oil and gas geophysical exploration. Because of micro-power dissipation, the seismograph and the sonar releaser can be integrated into a sphere cabin. By this means, the instrument's frequency of resonance and frequency of couple are improved obviously. The data acquisition system of OBS is improved from MCI seismometer. The capacity of flash memory is enlarge from 1G bytes to 8G bytes. The advance MPU in data acquisition system is used to integrate other function modules such as sonar, GPS, compass and digital transmitter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The seismic data acquisition system is the most important equipment for seismic prospecting. The geophysicists have been paying high attention to the specification of the equipment used in seismic prospecting. Its specification and performance are of great concerned to acquire precisely and accurately seismic data, which show us stratum frame. But, by this time, limited by the technology, most of the Broad-band Seismic Recorder (BSR) for lithosphere research of our country were bought from fremdness which were very costliness and maintained discommodiously. So it is very important to study the seismic data acquisition system.The subject of the thesis is the research of the BSR, several items were included, such as: seismic data digitizer and its condition monitor design.In the first chapter, the author explained the significance of the implement of BSR, expatiated the requirement to the device and introduced the actuality of the BSR in our country.In the second chapter, the collectivity architecture of the BSR system was illustrated. Whereafter, the collectivity target and guideline of the performance of the system design were introduced. The difficulty of the system design and some key technology were analyzed, such as the Electro Magnetic Compatibility (EMC), system reliability technology and so on.In the third chapter, some design details of BSR were introduced. In the recorder, the former analog to digital converter (ADC) was separated from the later data transition module. According to the characteristic of seismic data acquisition system, a set high-resolution 24-bit ADC chip was chosen to the recorder design scheme. As the following part, the noise performance of the seismic data channel was analyzed.In the fourth chapter, the embedded software design of each board and the software design of the workstation were introduced. At the same time the communication protocol of the each module was recommendedAt the last part of this thesis, the advantages and the practicability of the BSR system design were summarized, and the next development items were suggested.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Micro-fabrication technology has substantial potential for identifying molecular markers expressed on the surfaces of tissue cells and viruses. It has been found in several conceptual prototypes that cells with such markers are able to be captured by their antibodies immobilized on microchannel substrates and unbound cells are flushed out by a driven flow. The feasibility and reliability of such a microfluidic-based assay, however, remains to be further tested. In the current work, we developed a microfluidic-based system consisting of a microfluidic chip, an image grabbing unit, data acquisition and analysis software, as well as a supporting base. Specific binding of CD59-expressed or BSA-coupled human red blood cells (RBCs) to anti-CD59 or anti-BSA antibody-immobilized chip surfaces was quantified by capture efficiency and by the fraction of bound cells. Impacts of respective flow rate, cell concentration, antibody concentration and site density were tested systematically. The measured data indicated that the assay was robust. The robustness was further confirmed by capture efficiencies measured from an independent ELISA-based cell binding assay. These results demonstrated that the system developed provided a new platform to effectively quantify cellular surface markers effectively, which promoted the potential applications in both biological studies and clinical diagnoses.