288 resultados para aromatic compounds

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is found that the nitro substituent of some aromatic bifunctional compounds shows unusual reactivity towards protonation. In the chemical ionization mass spectra of nitrobenzoic acids and their esters and amides, and of nitrophenols and their ethers, protonations on the carboxyl, ester, amide, hydroxyl or alkoxyl groups are highly suppressed by that on the nitro group. As a result, fragmentations based on protonation on these groups unexpectedly become negligible. Ortho effects were observed for all the ortho isomers where the initial protonation on the nitro group is followed by an intramolecular proton transfer reaction, which leads to the expected 'normal' fragmentations. Protonation on the nitro substituent is much more favourable in energy than on any of the other substituents. The interaction of the two substituents through the conjugating benzene ring is found to be responsible for this 'unfair' competitive protonation. The electron-attracting nitro group strongly destabilizes the MH+ ions formed through protonation on the other substituent; although the COR (R = OH, OMe, OEt, NH2) groups are also electron-withdrawing, their effects are weaker than that of NO2; thus protonation on the latter group produces more-stable MH+ ions. On the other hand, an electron-releasing group OR (R = H, Me, Et) stabilizes the nitro-protonated species; the stronger the electron-donating effect of this group the more stable the nitro-protonated ions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple method, based on the technique of capillary column switching-back flushing, has been developed for the detailed analysis of aromatic compounds in gasoline. The sample was first separated on a 30-m long OV-2330 polar precolumn and then backflushed onto a nonpolar analytical column. The early eluting components from the precolumn and the components of interest (aromatic compounds plus heavier compounds) eluting from the analytical column are all directed to the same flame ionization detection system through a T piece, which permits the quantitative analysis of aromatic hydrocarbons in gasoline by a normalization method using correcting factors. The switching time window of the method is +/-5 s, resulting in easier operation and higher reliability. The reproducibility of the quantitative analysis was less than or equal to3% RSD for real gasoline samples. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An efficient method for the catalytic reduction of aromatic nitro compounds to the corresponding aromatic amines is reported. In the presence of selenium as a catalyst, the aromatic nitro compounds are quantitively reduced by CO/H2O to form the corresponding amines under atmospheric pressure. The reduction occurs in high selectivity regardless of other reducible functionalities present on the aromatic ring. There exists a phase transfer process of the catalyst selenium in the reaction. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work, the A(m) indices and the molecular connectivity indices of fifty aromatic compounds have been calculated, and applied for studying on relationship between partition coefficient and structure of aromatic compounds. The results demonstrate that the property of compounds can be described better with revisionary A(m) indices.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

With using short capillary column packed with porous and non-porous ODS stationary phases, high speed separation of 6 neutral aromatic compounds within 36 s by capillary electrochromatography (CEC) has been performed. Good reproducibility of the migration times for those solutes in high speed CEC was observed with RSD less than 1%. Both the linear velocity of EOF and the current linearly increases with the applied voltage, which means that the thermal effect by Joule heating was small. However, the capacity factor of solutes was found to decrease with the increase of the applied voltage, which was caused by the fact that about several seconds needed for the increase of voltage from 0 to applied value on a commercial CE instrument made larger contributions to the migration times of the early eluted compounds than those of lately eluted ones during high speed CEC, and voltage effect would increase with the higher applied voltage used. The linear relationship between the logarithm of capacity factor and the number of carbon for homologous compounds was observed, and positive value of slope means that the hydrophobicity of solutes is one of the main contribution factors to retention in high speed CEC packed with ODS stationary phases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Persistent bioaccumulative toxins (PBTs) are organic substances that are persistent, bioaccumulative and can cause severe toxic effects (e.g. potential oncogens, mutagenic, endocrine disrupters) to human health or environment which are the ones that need special attention. PBT chemicals could be released to the environment from several types of sources and are ubiquitous in environment. However, fast and efficiency monitoring and assessment methods to investigate PBTs in environment are still lacking. In this study, a cleaning-up procedure of analyzing PBTs in fuels combustion soot was developed and its performance was assessed through comparing the chromatograms of crude extracts with their cleaned extracts after the cleaning-up procedure. The results showed that polycyclic aromatic compounds (PACs) were the main components in fuel combustion soot and the clean-up procedure developed in this paper can be well used as the method of analyzing PBTs in fuels combustion soot.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel monolithic stationary phase having long alkyl chain ligands was introduced and evaluated in pressurized-capillary electrochromatography of small neutral and charged compounds. The monolithic column was prepared by the in situ copolymerization of ethylene dimethacrylate, 1-hexadecene, allyl alcohol and 2-acrylamido-2-methyl-1-propanesulfonic acid in a quaternary porogenic solvent mixture consisting of 1,4-butanediol, cyclohexanol, dodecanol and water.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A theoretical study on the velocity of electroosmotic flow (EOF) and the retention times of neutral solutes under multiple-step gradient of capillary electrochromatography (CEC) was carried out, focusing on that with three kinds of mobile phases. Through the model computations, the detaining time of the second kind of mobile phase in the column was proved to play an important role in affecting EOF. The variation speed of EOF was shown to be determined by the differences among dead times in different steps. In addition, the prediction of the retention times of 13 aromatic compounds under gradient mode was performed with the deduced equations. A relative error below 3.3% between the calculated and experimental values was obtained, which demonstrated the rationality of the theoretical deduction. Our study could not only improve the comprehension of stepwise gradient elution, but also be of significance for the further optimization of separation conditions in the analysis of complex samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Characteristics of electroosmotic flow (EOF) and the migration of neutral solutes under double stepwise gradient elution in capillary electrochromatography were studied systematically. EOF velocity proved to be the function of operation time changing with the introduction of the second mobile phase. Accordingly, the retention of components also changed. The migration of neutral solutes was studied under the following three situations; A, components eluted when the column was filled only with the first kind of mobile phase; B, solutes eluted still in the first kind of mobile phase while at that time two kinds of mobile phase coexisted in the column and C, samples eluted in the second kind of mobile phase. Equations to describe the retention times of components under these three kinds of conditions were deduced and applied to predict the retention times of 12 aromatic compounds. Relative errors between experimental and calculated values were below 5.0%, which proved the reliability of the equations. In addition, parameters that might affect the retention time of solutes, such as the transferring time of mobile phase vials, the capacity factors of components and EOF velocities two steps were studied systematically (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The optimization of the organic modifier concentration in micellar electrokinetic capillary chromatography (MECC) has been achieved by a uniform design and iterative optimization method, which has been developed for the optimization of composition of the mobile phase in high performance liquid chromatography. According to the proposed method, the uniform design technique has been applied to design the starting experiments, which can reduce the number of experiments compared with traditional simultaneous methods, such as the orthano design. The hierarchical chromatographic response function has been modified to evaluate the separation quality of a chromatogram in MECC. An iterative procedure has been adopted to search the optimal concentration of organic modifiers for improving the accuracy of retention predicted and the quality of the chromatogram. Validity of the optimization method has been proved by the separation of 31 aromatic compounds in MECC. (C) 2000 John Wiley & Sons, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel route for the synthesis of a variety of 2-trifluoromethylbenzofurans is reported. By selection of solvents, the key intermediates, 2-chloro-3,3,3-trifluoropropenyl phenyl acetates, were cyclized either to give 2-trifluoromethyl-substituted benzofurans or to yield trifluoromethyl modified o-alkynylphenols. The latter intermediates could also be cyclized to give 3-iodo-2-trifluoromethyl-substituted benzofurans.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The difference in the electrochemical behavior of hydroquinone and pyrocatechol. at platinum and gold surfaces was analyzed using voltammetry and attenuated total reflection Fourier transform infrared spectroscopy. The results show that the hydroquinone derivatives are adsorbed on a gold surface with vertical orientation, which makes the electron transfer between the bulk species and the electrode surface easier than that in the case of flat adsorption of hydroquinone derivatives that occurs at a platinum electrode. The formation of the vertical conformation and the rapid process of electron transfer were also confirmed by quantum chemistry calculations. In addition, the pre-adsorbed iodine on the electrodes played a key role on the adsorbed configuration and. electron transfer of redox species.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electrochemical polymerization of amino-derivatives of naphthalene has been studied on the platinum wire electrodes. The effects of acidity of the modifying media and the potential scan rate on the cyclic voltammograms are verified. As potentiometric pH sensors, the electrodes prepared from 1-naphthylamine and 2,3-diaminonaphthalene showed performance characteristics superior to some other electrodes tested. The electrode modified with 1-naphthylamine in the optimum medium showed a nearly Nernstian response of 4.20-13.70 pH and a slope of -54.8 mV/pH, while the linear range of the electrode prepared by 2,3-diaminonaphthalene was 4.00-13.60 pH, with a slope of -52.4 mV/pH.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

High-speed capillary electrochromatography was developed on both short and long packed columns with 2 mu m non-porous ODS as the stationary phase. Factors that affect the analysis time of samples, such as voltage, electrolyte concentration, pH and organic modifier concentration in the mobile phase, were studied systematically. Fast analysis of aromatic compounds within 13 seconds was realized with column efficiency of 573,000 plates/m and a R.S.D.% of the retention times of all components in 8 consecutive injections below 1.0%. which demonstrated the high efficiency and high reproducibility of such a technique. In addition, DNPH derived aldehydes and ketones in both standards and environmental samples were separated with high speed.