14 resultados para application development

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

激光陶瓷的出现,为固体激光材料向高功率、大尺寸、多功能发展提供了全新的途径,从而为激光技术的发展提供了更加灵活广阔的设计空间。介绍了近年来国际国内透明激光陶瓷及陶瓷激光器发展的最新进展,并展望了陶瓷激光器的未来发展价值。高功率陶瓷激光器方面:中科院上海光学精密机械研究所采用超均匀侧面泵浦技术在1at.%Nd:YAG陶瓷棒中获得输出功率236W,斜率效率62%的连续激光输出。美国利弗莫尔实验室采用Sm3+包边Nd:YAG复合结构陶瓷热容激光器实现了5Hz,67kW激光输出。陶瓷激光器方面,日本World-Labo.Co实验室采用掺杂浓度为15at.%的Yb:YSAG透明陶瓷,获得脉冲宽度280fs,平均输出能量为62mW的锁模脉冲激光输出。陶瓷自调Q脉冲激光器和陶瓷光纤激光器亦有很大进展。陶瓷激光器的开发和应用不仅延伸到传统固体激光器的各个研究领域,并且能够不断突破现有固体激光技术的局限,有望推动未来固体激光工程向更广阔的空间发展。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

本文综述了气压伺服应用情况、发展概况、存在的问题、气液连动的重要性及发展概况。

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new type of sensor with the flexible substrate is introduced. It is applicable in measuring instantaneous heat flux on the model surface in a hypersonic shock tunnel. The working principle, structure and manufacture process of the sensor are presented. The substrate thickness and the dynamic response parameter of the sensor are calculated. Because this sensor was successfully used in measuring the instantaneous heat flux on the surface of a flat plate in a detonation-driven shock tunnel, it may be effective in measuring instantaneous heat flux on the model surface.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper introduced a long-term ambulatory intragastric pH monitoring system, which is designed for prolonged ambulatory studies of Gastroesophageal Reflux Diseases. The whole system is composed of the gastric catheter with two pH sensors, a small data logger (Microdatalog), and a notebook PC. In this paper, the design of monitoring system hardware and software are described in detail. Clinical applications reveal good results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Silica-based functionalized terbium fluorescent nanoparticles were prepared, characterized and developed as a fluorescence probe for antibody labeling and time-resolved fluoroimmunoassay. The nanoparticles were prepared in a water-in-oil (W/O) microemulsion containing a strongly fluorescent Tb3+ chelate. N,N.N-1,N-1-12,6-bis(3'-aminomethyl-1'-pyrazolyl)phenylpyridine] tetrakis(acetate)-Tb3+ (BPTA-Tb3+), Triton X-100, octanol, and cyclohexane by controlling copolymerization of tetraethyl orthosilicate (TEOS) and 3-[2-(2- aminoethylamino)-ethylamino]propyl-trimethoxysilane (AEPS) with ammonia water. The characterizations by transmission electron microscopy and fluorometric quantum methods show that the nanoparticles are spherical and uniform in size, 45 +/- 3 nm in diameter, strongly fluorescent with fluorescence yield of 10% and a long fluorescence lifetime of 2.0 ms. The amino groups directly introduced to the nanoparticle's surface by using AEPS in the preparation made the surface modification and bioconjugation of the nanoparticles easier. The nanoparticle-labeled anti-human alpha-fetoprotein antibody was prepared and used for time-resolved fluoroimmunoassay of (x-fetoprotein (AFP) in human serum samples. The assay response is linear from 0.10 ng ml(-1) to about 100 ng ml(-1) with the detection limit of 0.10 ng ml(-1). The coefficient variations (CVs) of the method are less than 9.0%. and the recoveries are in the range of 84-98% for human serum sample measurements. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper reports the development of SSR markers from EST data and their utilization in germplasm identification of Porphyra. The publicly available EST (expressed sequence tag) sequences of Porphyra were searched from the Internet (www.kazura.or.jp/en/plant/porphyra/EST/). From a total of 20,779 obtained EST sequences, 391 SSRs (simple sequence repeats) were analysed with SSRIT software (www.gramene.org/db/searches/ssrtool). From those, 48 SSR primer-pairs were designed and tested by commonly used SSR reaction conditions using 22 Porphyra DNA samples as templates. Results showed that 41 SSR primer-pairs gave good amplification patterns. These were used to conduct SSR analyses of genetic diversity and variety identification of the 22 Porphyra lines. A dendrogram and the DNA fingerprints of the Porphyra lines were developed based on the obtained SSR data.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A pre-column derivatization method for the sensitive determination of amino acids and peptides using the tagging reagent 1,2-benzo-3,4dihydrocarbazole-9-ethyl chloroformate (BCEOC) followed by high-performance liquid chromatography with fluorescence detection has been developed. Identification of derivatives was carried out by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS/MS). The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent was replaced by 1,2-benzo-3,4-dihydrocarbazole functional group, which resulted in a sensitive fluorescence derivatizing reagent BCEOC. BCEOC can easily and quickly label peptides and amino acids. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography. The derivatives showed an intense protonated molecular ion corresponding m/z (M + H)(+) under electrospray ionization (ESI) positive-ion mode with an exception being Tyr detected at negative mode. The collision-induced dissociation of protonated molecular ion formed a product at m/z 246.2 corresponding to the cleavage of C-O bond of BCEOC molecule. Studies on derivatization demonstrate excellent derivative yields over the pH 9.0-10.0. Maximal yields close to 100% are observed with a 3-4-fold molar reagent excess. Derivatives exhibit strong fluorescence and extracted detzvatization solution with n-hexane/ethyl acetate (10:1, v/v) allows for the direct injection with no significant interference from the major fluorescent reagent degradation by-products, such as 1,2-benzo-3,4-dihydrocarbazole-9-ethanol (BDC-OH) (a major by-product), mono- 1,2-benzo-3,4-dihydrocarbazole-9-ethyl carbonate (BCEOC-OH) and bis-(1,2-benzo-3,4-dihydrocarbazole-9-ethyl) carbonate (BCEOC)(2). In addition, the detection responses for BCEOC derivatives are compared to those obtained with previously synthesized 2-(9-carbazole)-ethyl chloroformate (CEOC) in our laboratory. The ratios AC(BCEOC)/AC(CEOC) = 2.05-6.51 for fluorescence responses are observed (here, AC is relative fluorescence response). Separation of the derivatized peptides and amino acids had been optimized on Hypersil BDS C-18 column. Detection limits were calculated from 1.0 pmol injection at a signal-to-noise ratio of 3, and were 6.3 (Lys)-177.6 (His) fmol. The mean interday accuracy ranged from 92 to 106% for fluorescence detection with mean %CV < 7.5. The mean interday precision for all standards was < 10% of the expected concentration. Excellent linear responses were observed with coefficients of > 0.9999. Good compositional data could be obtained from the analysis of derivatized protein hydrolysates containing as little as 50.5 ng of sample. Therefore, the facile BCEOC derivatization coupled with mass spectrometry allowed the development of a highly sensitive and specific method for the quantitative analysis of trace levels of amino acids and peptides from biological and natural environmental samples. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, oxygen permeable membrane used in membrane reactor for selective oxidation of alkanes will be discussed in detail. The recent developments for the membrane materials will be presented, and the strategy for the selection of the membrane materials will be outlined. The main applications of oxygen permeable membrane in selective oxidation of light alkanes will be summarized, which includes partial oxidation of methane (POM) to syngas and partial oxidation of heptane (POH) to produce H-2, oxidative coupling of methane (OCM) to C-2, oxidative dehydrogenation of ethane (ODE) to ethylene and oxidative dehydrogenation of propane (ODP) to propylene. Achievements for the membrane material developments and selective oxidation of light alkanes in membrane reactor in our group are highlighted.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this study, an in vitro multicellular tumor spheroid model was developed using microencapsulation, and the feasibility of using the microencapsulated. multicellular tumor spheroid (MMTS) to test the effect of chemotherapeutic drugs was investigated. Human MCF-7 breast cancer cells were encapsulated in alginate-poly-L-lysine-alginate (APA) microcapsules, and a single multicellular spheroid 150 mu m in diameter was formed in the microcapsule after 5 days of cultivation. The cell morphology, proliferation, and viability of the MMTS were characterized using phase contrast microscopy, BrdU-Iabeling, MTT stain, calcein AM/ED-2 stain, and H&E stain. It demonstrated that the MMTS was viable and that the proliferating cells were mainly localized to the periphery of the cell spheroid and the apoptotic cells were in the core. The MCF-7 MMTS was treated with mitomycin C (MC) at a concentration of 0.1, 1, or 10 times that of peak plasma concentration (ppc) for up to 72 h. The cytotoxicity was demonstrated. clearly by the reduction in cell spheroid size and the decrease in cell viability. The MMTS was further used to screen the anticancer effect of chemotherapeutic drugs, treated with MC, adriamycin (ADM) and 5-fluorouracil (5-FU) at concentrations of 0.1, 1, and 10 ppc for 24, 48, and 72 h. MCF-7 monolayer culture was used as control. Similar to monolayer culture, the cell viability of MMTS was reduced after treatment with anticancer drugs. However, the inhibition rate of cell viability in MMTS was much lower than that in monolayer culture. The MMTS was more resistant to anticancer drugs than monolayer culture. The inhibition rates of cell viability were 68.1%, 45.1%, and 46.8% in MMTS and 95.1%, 86.8%, and 91.6% in monolayer culture treated with MC, ADM, and 5-FU at 10 ppc for 72 h, respectively. MC showed the strongest cytotoxicity in both MMTS and monolayer, followed by 5-FU and ADM. It demonstrated that the MMTS has the potential to be a rapid and valid in vitro model to screen chemotherapeutic drugs with a feature to mimic in vivo three-dimensional (3-D) cell growth pattern.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An immunosorbent was fabricated by encapsulation Of monoclonal anti-isoproturon antibodies in sol-gel matrix. The immunosorbent-based loading, rinsing and eluting processes were optimized. Based on these optimizations, the sol-gel immunosorbent (SG-IS) selectively extracted isoproturon from an artificial mixture of 68 pesticides. In addition to this high selectivity, the SG-IS proved to be reusable. The SG-IS was combined with liquid chromatography-tandem mass spectrometry (LC-MS-MS) to determine isoproturon in surface water, and the linear range was up to 2.2 mu g/l with correlation coefficient higher than 0.99 and relative standard deviation (RSD) lower than 5% (n = 8). The limit of quantitation (LOQ) for 25-ml surface water sample was 5 ng/l. (c) 2006 Elsevier B.V. All rights reserved.