100 resultados para Viscosity measurement

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

To clarify the mechanism of organic-inorganic hybrid membrane formation by phase-inversion method, the thermodynamical and theological properties of PSF/TiO2 casting solution were investigated by the viscosity measurement and the triangle phase diagram, respectively. TiO2 introduction decreased the non-solvent tolerance of casting solution with non-solvent 20% ethanol aqueous solution, which caused thermodynamic enhancement of phase separation, and also resulted in the change of theological properties from Newtonian fluid to non-Newtonian fluid and the viscosity increase of casting solution, which induced rheological hindrance in demixing process

Relevância:

60.00% 60.00%

Publicador:

Resumo:

琼胶是一种从石花菜等红藻中提取的,目前生产工艺和结构等方面研究比较成熟的海藻多糖,广泛应用于医药、仪器等行业。但是,海藻多糖因为具有分子量大,粘度大,溶解度较小的等特点,而使其应用范围受到限制。利用降解的手段对其进行修饰,降低分子量和粘度,改善溶解性,可以拓展其应用范围。并且根据文献报道,琼 胶寡糖具有一些特殊的生物活性,如抗氧化性,抗炎症等。因此,对琼胶降解的研究具有生要意义。本研究中,为了选择一种合适的降解方法,进行了几种水解方法的尝试,其中包括在不同湿度和酸度下盐酸水解,过氧化氢和醋酸催化水解,Fenton体系羟基自由基降解。对于酸水解和Fenton体系氧化还原降解方法,通过粘度法对反应的速度进行了比较,表明氧化还原降解反应中琼胶的粘度降低比较快,并且具有代表性和新意,确定为本实验的降解琼胶的方法并对氧化还原降解所得的产物进行了活性实验。通过模仿自然界普遍存在的氧化还原降解反应,利用Vc诱导的Fenton体系产生的羟基自由基氧化还原降解琼胶得到低分子量的琼胶。降解产物经过高速离心、60%乙醇沉淀,除去分子量比较大的降解产物和磷酸盐,得到可溶于60%乙醇的分子量估计小于3000的降争产物,其产率为85%。利用经Sephadex-G25凝胶色谱分离所香的不同分子量的级分进行分子量和α-葡萄糖苷酶抑制活性关系的实验。降解产物对α-葡萄糖苷酶的抑制率和各级分的浓度呈线性正相关,并且各级分的IC_(50)则随着分子量的降低而降低。另外,对所得的降解产物混合物进行了红外吸收光谱、质子去偶核磁共震碳谱和负离子基质辅助激光诱导-飞行时间质谱结构分析。结果表明,氧化还原降解反应的专一性差,在得到寡糖的同时,在光谱图中出现一些比较复杂的副产物的结构信息。最后,根据MTT法的原理,以有体皮肤成纤维细胞为材料,通过紫外线辐射产生自由基造成氧化损伤,研究降解产物对成纤维细胞的保护作用。当无紫外线辐射时,降解产物对成纤维细胞具有显著的促进生长增殖作用:当经UVa、UBb辐射时则可以显著地表现出对损伤的保护作用,并且这种促进生长和保护作用呈显著的量效关系,表明降解产物具有清除基自由基的作用。但是,因为氧化还原降解以应的机理尚不十分明的以及琼羟胶的特殊结构,使得反应的副产物很难预测,也就使得分离工作难以进行,所以,根据目前所得的信息,尚不能确定是降解产物的什么级分产生的以上两种生物活性。

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present paper the measured values of vibrational temperature behind strong shock waves are compared with theoretical ones. The histories of vibrational temperature behind strong shock waves in a shock tube were measured using two monochromators. The test gas was pure nitrogen at 100-300Pa, and the speeds of shock waves were 5.0-6.0km/s. The electronic temperature of N-2(+) was also approximately determined from experiment and compared with the experimental vibrational temperature. The results show that the presented calculational method is effective, and the electronic energy of N2+ is excited much faster than its vibrational energy. One Langmuir probe was used to determine the effective time of region 2. The influence of viscosity in the shock tube is also analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal properties of a micro-electromechanical system sensor were analysed by a novel digital moire method. A double-layer micro-cantilever sensor (60 mu m long, 10 mu m width and 2 mu dm thick) was prepared by focused ion beam milling. A grating with frequency of 5000 lines mm- I was etched on the cantilever. The sensor was placed into a scanning electron microscope system with a high temperature device. The observation and recording of the thermal deformation of the grating were realised in real-time as the temperature rose from room temperature to 300 degrees C at intervals of 50 degrees C. Digital moire was generated by interference of the deformed grating and a digital virtual grating. The thermal properties including strain distribution of the sensor and the linear expansion coefficient of polysilicon were accurately measured by the phase-shifted moire patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction of small amount of CF4 premixed in the test gas. The final product C2F4 is used as the temperature indicator, which is sampled and detected by a gas chromatography in the experiment. The detected concentration of C2F4 is correlated to the temperature of the reflected shock wave with the initial pressure P-1 and test time tau as parameters in the temperature range 3 300 K < T < 5 600 K, pressure range 5 kPa < P1 <12 kPa and tau similar or equal to 0.4 ms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The property of crystal depends seriously on the solution concentration distribution near the growth surface of a crystal. However, the concentration distributions are affected by the diffusion and convection of the solution. In the present experiment, the two methods of optical measurement are used to obtained velocity field and concentration field of NaClO3 solution. The convection patterns in sodium chlorate (NaClO3) crystal growth are measured by Digital Particle image Velocimetry (DPIV) technology. The 2-dimentional velocity distributions in the solution of NaClO3 are obtained from experiments. And concentration field are obtained by a Mach-Zehnder interferometer with a phase shift servo system. Interference patterns were recorded directly by a computer via a CCD camera. The evolution of velocity field and concentration field from dissolution to crystallization are visualized clearly. The structures of velocity fields were compared with that of concentration field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present density measurements from the application of interferometry and Fourier transform fringe analysis to the problem of nonstationary shock wave reflection over a semicircular cylinder and compare our experimental measurements to theoretical results from a CFD simulation of the same problem. The experimental results demonstrate our ability to resolve detailed structure in this complex shock wave reflection problem, allowing visualization of multiple shocks in the vicinity of the triple point, plus visualization of the shear layer and an associated vortical structure. Comparison between CFD and experiment show significant discrepancies with experiment producing a double Mach Reflection when CFD predicts a transitional Mach reflection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the real-time deformation fields are observed in two different kinds of hole-excavated dog-bone samples loaded by an SHTB, including single hole sample and dual holes sample with the aperture size of 0.8mm. The testing system consists of a high-speed camera, a He-Ne laser, a frame grabber and a synchronization device with the controlling accuracy of I microsecond. Both the single hole expanding process and the interaction of the two holes are recorded with the time interval of 10 mu s. The observed images on the sample surface are analyzed by newly developed software based on digital correlation theory and a modified image processing method. The 2-D displacement fields in plane are obtained with a resolution of 50 mu m and an accuracy of 0.5 mu m. Experimental results obtained in this paper are proofed, by compared with FEM numerical simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

微电子机械系统(MEMS)技术的迅速崛起,推动了所用材料微尺度力学性能测试技术的发展.首先按作用方式将实验分成压痕/划痕、弯曲、拉伸、扭转四大类,系统介绍检测MEMS材料微尺度力学性能的微型试样、测试方法及其实验结果.测试材料主要有硅、氧化硅、氮化硅和一些金属.实验结果主要包括基本的力学性能参数如弹性模量、残余应力、屈服强度、断裂强度和疲劳强度等.最后,简要分析了未来的发展需求.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new X-ray diffraction method for characterising thermal mismatch stress (TMS) in SiCw–Al composite has been developed. The TMS and thermal mismatch strain (TMSN) in SiC whiskers are considered to be axis symmetrical, and can be calculated by measuring the lattice distortion of the whiskers. Not only the average TMS in whiskers and matrix can be obtained, but the TMS components along longitudinal and radial directions in the SiC whiskers can also be deduced. Experimental results indicate that the TMS in SiC whiskers is compressive, and tensile in the aluminium matrix. The TMS and TMSN components along the longitudinal direction in the SiC whiskers are greater than those along the radial direction for a SiCw–Al composite quenched at 500°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article is the result of experimental studies of the rheologv, viscosities, surface tensions, and atomization of water-methanol and diesel emulsions. The Span 80 and Tween 60 are employed to make three emulsifying agents, Y01, Y02, and Y03, with viscosity of 1.32-1.5 Pa s and HLB values of 5.36, 4.83, and 4.51, respectively. In the water-in-oil emulsions, the aqueous phase is between 10% and 50%; the agent concentration added is 0.8-8.0%. The viscosity of the emulsions is 0.003-0.02 Pa s, and the surface tens ion is 0.04-0.1 N/m. The types and concentrations of agents significantly influence the viscosity of the emulsions, and the higher concentration of the aqueous phase (<50%) in creases the viscosities of the emulsions, especially for higher agent concentration. Interfacial membrane and HLB values of the agents can explain all these phenomena. Higher aqueous phase concentration and agent viscosity results in larger Sauter mean diameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

对涡轮流量传感器进行了理论分析,给出了涡轮流量计仪表常数的计算方法,讨论了获得较大固有仪表常数K_0时涡轮传感器结构参数(如叶片数、涡轮半径、口径等)的优化组合问题,通过多相流动实验,总结出K_0与流动密度之间的实验关系,由此给出用涡轮流量计测量多相流的半理论半经验公式,并在油井多相流量测量中得到了实际应用,符合较好。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a real-time and in situ optical measuring system is reported to observe high-velocity deformations of samples subjected to impact loading. The system consists of a high-speed camera, a He-Ne laser, a frame grabber, a synchronization device and analysis software based on digital correlation theory. The optical system has been adapted to investigate the dynamic deformation field and its evolution in notched samples loaded by an split Hopkinson tension bar, with a resolution of 50 pin and an accuracy of 0.5 mum. Results obtained in experiments are discussed and compared with numerical simulations. It is shown that the measuring system is effective and valid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Turbidity measurement for the absolute coagulation rate constant of suspensions has been extensively adopted because of its simplicity and easy implementation. A key factor to derive the rate constant from experimental data is how to theoretically evaluate the so-called optical factor involved in calculating the extinction cross section of doublets formed in the aggregation. In a previous paper, we have shown that compared with other theoretical approaches, the T-matrix method provides a robust solution to this problem and is effective in extending the applicability range of the turbidity methodology as well as increasing measurement accuracy. This paper will provide a more comprehensive discussion about the physical insight of using the T-matrix method in turbidity measurement and associated technical details. In particular, the importance of ensuring the correct value for the refractive indices for colloidal particles and the surrounding medium used in the calculation is addressed because the indices generally vary with the wavelength of the incident light. The comparison of calculated results with experiments shows that the T-matrix method can correctly calculate optical factors even for large particles, whereas other existing theories cannot. In addition, the calculated data of the optical factor by the T-matrix method for a range of particle radii and incident light wavelengths are listed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two principal problems of equivalency and locality in nano-scale measurement are considered in this paper. The conventional measurements of force and displacement are always closely related to the equivalency problem between the measuremental results by experimental system and the real physical status of the sample, and the locality of the mechanical quantities to be measured. There are some noticeable contradictions in nano-scale measurements induced by the two problems. In this paper, by utilizing a coupled molecular-continuum method, we illustrate the important effects of the two principal problems in atomic force microscopy (AFM) measurements on nano-scale. Our calculations and analysis of these typical mechanical measurement problems suggest that in nano-meter scale measurements, the two principal problems must be carefully dealt with. The coupled molecular-continuum method used in this paper is very effective in solving these problems on nano-scale.