3 resultados para Thermometers.

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A temperature-controlled pool boiling (TCPB) device was developed to perform pool boiling heat transfer studies at both normal gravity on Earth and microgravity in the drop tower Beijing and aboard a Chinese recovery satellite. Two platinum wires of 60 ?m in diameter were simultaneously used as heaters and thermometers. The lengths were 30 mm and 40 mm, respectively. The ends of wires were soldered with copper poles to provide low resistance paths for the electric current. The heater resistance, and thus the heater temperature, was kept constant by a feedback circuit similar to that used in constant-temperature hot-wire anemometry. The fluid was R113 at 0.1 Mpa and subcooled by 30 ?C nominally for all cases. The results of the experiments at normal gravity were presented. Four modes, namely single-phase convection, nucleate boiling, transition two-mode boiling, and film boiling were observed. A few data obtained from several preliminary experiments at microgravity in the drop tower Beijing were also presented. A slight increase of the heat flux was obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:


A temperature-controlled poolboiling (TCPB) device was developed to perform poolboiling heat transfer studies at both normal gravity and microgravity. A platinum wire of 60 μm in diameter and 30 mm in length was simultaneously used as heaters and thermometers. The heater resistance, and thus the heater temperature, was kept constant by a feedback circuit. The fluid was R113 at 0.1 Mpa and subcooled by 24 nominally for all cases. The results of the experiments at both normal gravity and microgravityin the Drop Tower Beijing were presented. Nucleate and two-mode transition boiling were observed. For nucleate boiling, the heat transfer was slightly enhanced, namely no more than 10% increase of the heat flux was obtained inmicrogravity, while the bubble pattern is dramatically altered by the variation of the acceleration. For two-mode transition boiling, about 20% decrease of the heat flux was obtained, although the part of film boiling was receded inmicrogravity. A scale analysis on the Marangoni convection surrounding bubble in the process of subcooled nucleate poolboiling was also presented. The characteristic velocity of the lateral motion and its observability were obtained approximately. The predictions consist with theexperimental observations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a need for methodology to warm open-field plots in order to study the likely effects of global warming on ecosystems in the future. Herein, we describe the development of arrays of more powerful and efficient infrared heaters with ceramic heating elements. By tilting the heaters at 45 degrees from horizontal and combining six of them in a hexagonal array, good uniformity of warming was achieved across 3-m-diameter plots. Moreover, there do not appear to be obstacles (other than financial) to scaling to larger plots. The efficiency [eta(h) (%); thermal radiation out per electrical energy in] of these heaters was higher than that of the heaters used in most previous infrared heater experiments and can be described by: eta(h) = 10 + 25exp(-0.17 u), where u is wind speed at 2 m height (m s(-1)). Graphs are presented to estimate operating costs from degrees of warming, two types of plant canopy, and site windiness. Four such arrays were deployed over plots of grass at Haibei, Qinghai, China and another at Cheyenne, Wyoming, USA, along with corresponding reference plots with dummy heaters. Proportional integral derivative systems with infrared thermometers to sense canopy temperatures of the heated and reference plots were used to control the heater outputs. Over month-long periods at both sites, about 75% of canopy temperature observations were within 0.5 degrees C of the set-point temperature differences between heated and reference plots. Electrical power consumption per 3-m-diameter plot averaged 58 and 80 kW h day(-1) for Haibei and Cheyenne, respectively. However, the desired temperature differences were set lower at Haibei (1.2 degrees C daytime, 1.7 degrees C night) than Cheyenne (1.5 degrees C daytime, 3.0 degrees C night), and Cheyenne is a windier site. Thus, we conclude that these hexagonal arrays of ceramic infrared heaters can be a successful temperature free-air-controlled enhancement (T-FACE) system for warming ecosystem field plots.