107 resultados para TRACE GASES
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
The purpose of this article is to examine the methods and equipment for abating waste gases and water produced during the manufacture of semiconductor materials and devices. Three separating methods and equipment are used to control three different groups of electronic wastes. The first group includes arsine and phosphine emitted during the processes of semiconductor materials manufacture. The abatement procedure for this group of pollutants consists of adding iodates, cupric and manganese salts to a multiple shower tower (MST) structure. The second group includes pollutants containing arsenic, phosphorus, HF, HCl, NO2, and SO3 emitted during the manufacture of semiconductor materials and devices. The abatement procedure involves mixing oxidants and bases in an oval column with a separator in the middle. The third group consists of the ions of As, P and heavy metals contained in the waste water. The abatement procedure includes adding CaCO3 and ferric salts in a flocculation-sedimentation compact device equipment. Test results showed that all waste gases and water after the abatement procedures presented in this article passed the discharge standards set by the State Environmental Protection Administration of China.
Resumo:
A hot particle jet is induced as a laser pulse from a free oscillated Nd:YAG laser focused on a coal target. The particle jet successfully initiates combustion in a premixed combustible gas consisting of hydrogen, oxygen, and air. The experiment reveals that the ionization of the particle jet is enhanced during the laser pulse. This characteristic is attributed to the electron cascade process and the ionization of the particles or molecules of the target. The initial free electrons, which are ablated from the coal target, are accelerated by the laser pulse through the inverse Bremsstrahlung process and then collide with the neutrals in the jet, causing the latter to be ionized.
Resumo:
This paper describes a novel method that applies pressure-assisted field-amplified sample injection with reverse migrating micelles (PA-FASI-RMM) for the online concentration of neutral analytes in MEKC with a low-pH BGE. After injection of a plug of water into the separation capillary, negative voltage and positive pressure were simultaneously applied to initialize PA-FASI-RMM injection. The hydrodynamic flow generated by the positive pressure compensated the reverse EOF in the water plug and allowed the water plug to remain in the capillary during FASI with reverse migrating micelles (FASI-RMM) to obtain a much longer injection time than usual, which improved stacking efficiency greatly. Equations describing this injection mode were introduced and were supported by experimental results. For a 450-s online PA-FASI-RMM injection, three orders of magnitude sample enhancement in terms of peak area could be observed for the steroids and an achievement of detection limits was between 1 and 10 ng/mL.
Resumo:
The ratio of methanol., water and trifluoroacetic acid ( TFA) was regulated to change the polarity and the pH of the rinse solution and the eluent, so as to improve the high performance liquid chromatography HPLC) detection method for trace microcystines (MCs) in natural water bodies. The results showed that 40 % similar to 45 % methanol-water solution containing 0. 1 % TFA could get good effects on the rinse of impurity, and 70% methanol-water solution containing 0. 1% TFA could elute all the MCs in solid phase extraction ( SPE) cartridge ( C-18), In this way. it is suggested that, in analysis of environmental samples with high concentration of impurity, impurity should be washed with 40% similar to 45% methanol-water solution containing 0. 1% TFA, and MCs should be eluted with 70% similar to 100% methanol-water solution containing 0. 1% TFA.
Resumo:
Total and subcellular hepatic Zn, Cu, Se, Mn, V, Hg, Cd, and Ag were determined in a mother-fetus pair of Dall's porpoises (Phocoenoides dalli). Except for higher fetal Cu concentration, all maternal elements were higher. Elements existed mostly in the cytosol of both animals except in the case of maternal Ag in the microsome and fetal Cu and Ag in the nuclei and mitochondria. In the maternal cytosol, Zn, Mn, Hg, and Ag were present in the high-molecular-weight substances (HMW); Se and V were present in the low-molecular-weight substances (LMW); Cu and Cd were mostly sequestered by metallothionein (MT). In the fetal cytosol, Zn, Se, Mn, Hg, Cd, and Ag were present in the HMW and V in the LMW, while Cu and Ag were mostly associated with MT. MT isoforms were characterized using the HPLC/ICP-MS. Two and four obvious peaks appeared in the maternal and fetal MT fractions, respectively. The highest elemental ion intensities were at a retention time of 7.8 min for the mother, and for the fetus the peak elemental ion intensities occurred at a retention time of 4.3 min, suggesting that different MT isoforms may be involved in elemental accumulation in maternal and fetal hepatocytosols. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Concentration of trace elements measured by dry weight basis has become more commonly used in recent studies on cetaceans than wet weight basis, which was used more in earlier studies. Because few authors present moisture content data in their papers, it is difficult to compare the concentrations of trace elements between various studies. Therefore, we felt that it would be useful if a reference conversion factor (CF) for tissue types could be found to convert between wet weight and dry weight data on trace element concentrations. We determined the moisture contents of 14 tissues of Dall's porpoise (Phocoenoides dalli), and then, calculated the CF values for those tissues. Because the moisture content of each tissue differs from other tissues, it is necessary to use a specific CIF for each tissue rather than a general CF for several tissues. We have also found that CIF values for Dall's porpoise tissues are similar to the same tissues in other cetaceans. Therefore CF values from Dall's porpoise can be reliably used to convert between wet and dry weight concentrations for other cetacean tissues as reference data. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
This paper presents a method for trace level analysis of microcystins in water using solid-phase extraction and high performance liquid chromatography. The optimized condition enabled the determination of common microcystins at levels as low as 0.02 similar to 0.05 mug/L, and the liner range is from 0.1 mug/L to 50 mug/L. The method has been applied to the analysis of field sample from Dianchi lake.
Resumo:
On the metalorganic chemical vapour deposition growth of AlN, by adjusting H-2+N-2 mixture gas components, we can gradually control island dimension. During the Volmer - Weber growth, the 2-dimensional coalescence of the islands induces an intrinsic tensile stress. Then, this process can control the in-plane stress: with the N-2 content increasing from 0 to 3 slm, the in-plane stress gradually changes from 1.5 GPa tensile stress to - 1.2GPa compressive stress. Especially, with the 0.5 slm N-2 + 2.5 slm H-2 mixture gas, the in-plane stress is only 0.1 GPa, which is close to the complete relaxation state. Under this condition, this sample has good crystal and optical qualities.
Resumo:
We have investigated the photo-excited capacitance-voltage (C-V) characteristics as well as the photoluminescence spectra under different biases of a wide quantum well (QW) embedded in an n(+)-i-n(+) double-barrier structure. The pronounced peak feature at zero bias in the C-V spectrum observed upon illumination is regarded as a kind of quantum capacitance related to the quantum confined Stark effect, originating from the spatial separation of the photo-generated electron and hole gas in the QW. This fact is further demonstrated through the comparison between the C-V curve with the PL intensity versus applied voltage relationship under the same excitation. The results may provide us with a more direct and sensitive means in the detection of the separation and accumulation of both types of free carriers-electrons and holes-in low-dimensional semiconductor structures, especially in a new type of optical memory cell.