112 resultados para Reproducibility

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The differential cross sections of the dissipative products B, Q N, O, F, Ne, Na and Mg induced from the reactions of F-19+Al-27 at two incident energies have been measured at the HI-13 tandem accelerator, Beijing. In the case of a fixed beam incident energy 114MeV or 118.75MeV respectively, identical reaction system and the same detection system, 20 target points in steps of 2mm on(.)a 10mmx50mm rectangular Al foil have been bombarded. The experimental results indicate that the probability distribution of the cross sections is much wider than a standard Gaussian distribution. This non-reproducibility of the cross sections can't be interpreted by the statistical property of a finite count rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The feasibility of using protein A to immobilize antibody on silicon surface for a biosensor with imaging ellipsometry was presented in this study. The amount of human IgG bound with anti-IgG immobilized by the protein A on silicon surface was much more than that bound with anti-IgG immobilized by physical adsorption. The result indicated that the protein A could be used to immobilize antibody molecules in a highly oriented manner and maintain antibody molecular functional configuration on the silicon surface. High reproducibility of the amount of antibody immobilization and homogenous antibody adsorption layer on surfaces could be obtained by this immobilization method. Imaging ellipsometry has been proven to be a fast and reliable detection method and sensitive enough to detect small changes in a molecular monolayer level. The combination of imaging ellipsometry and surface modification with protein A has the potential to be further developed into an efficient immunoassay protein chip.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A concise pressure controlled isothermal heating vertical deposition (PCIHVD) method is developed, which provides an optimal growing condition with better stability and reproducibility for fabricating photonic crystals (PCs) without the limitation of colloidal sphere materials and sizes. High quality PCs are fabricated with PCIHVD from polystyrene spheres with diameters ranging from 200 nm to 1 mu m. The deep photonic band gap and steep photonic band edge of the samples are most favorable for realizing ultrafast optical devices, photonic chips, and communications. This method makes a meaningful advance in the quality and diversity of PCs and greatly promotes their wide applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The subject of the present work is to report an experimental comparative study of the effect of dispersion-induced turbulence on dust combustion in constant volume vessel, carried out both in normal gravity and in microgravity environment. Dispersion system with small scale of turbulence, creating uniform homogeneous mixture, was used in experiments. To improve reproducibility of the explosion data an ignitor of small energy, with local soft ignition was developed. Both factors contributed to acquisition of more reproducible experimental data. In experiments under microgravity conditions a dust suspension during combustion remains constant. This makes possible to study dust explosion under stationary dust suspension without influence of turbulence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

提出一种步进扫描投影光刻机承片台不平度检测新技术。在晶圆与承片台存在不同偏移量时,利用线性差分传感器在线测量晶圆上不同点的局部高度;通过建立临时边界条件,以递推法消除晶圆面形影响,并逐行计算出承片台的相对不平度;通过逐行计算的结果递推相邻行之间的高度差,并将该高度差叠加到每一行,以消除临时边界条件的限制,得到处于同一高度上的承片台不平度;将计算的结果作为初始值,根据最小二乘原理,以邻近的四个测量点作为参考,逐步逼近得到承片台的真实不平度。计算机仿真结果验证了该检测方法的正确性,计算结果逐步收敛并逼近真实值

Relevância:

10.00% 10.00%

Publicador:

Resumo:

提出一种新的步进扫描投影光刻机工件台方镜不平度测量方法。以方镜平移补偿量与旋转补偿量为测量目标,使用两个双频激光干涉仪分别测量工件台在x和y方向的位置和旋转量;将方镜不平度的测量按照一定的偏移量分成若干个序列,每一个序列包括对方镜有效区域的若干次往返测量;根据所有序列的测量结果计算出方镜的旋转补偿量;为每一个序列建立临时边界条件,并据此计算出每一序列所测得的方镜粗略平移补偿量;采用三次样条插值与最小二乘法建立每一个序列间的关系,以平滑连接所有测量序列得到精确的方镜平移补偿量。结果表明,该方法用于测量方镜平

Relevância:

10.00% 10.00%

Publicador:

Resumo:

提出一种精确检测光刻机激光干涉仪测量系统非正交性的新方法。将对准标记曝光到硅片表面并进行显影;利用光学对准系统测量曝光到硅片上的对准标记理论曝光位置与实际读取位置的偏差;由推导的位置偏差与非正交因子、坐标轴尺度比例、过程引入误差的线性模型,根据最小二乘原理计算出干涉仪测量系统的非正交性。实验结果表明,利用该方法使用同一硅片在不同旋转角下进行测量,干涉仪测量系统非正交因子的测量重复精度优于0.01 μrad,坐标轴尺度比例的测量重复精度优于0.7×10-6。使用不同的硅片进行测量,非正交因子的测量再现性优于

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Topography of a granite surface has an effect on the vertical positioning of a wafer stage in a lithographic tool, when the wafer stage moves on the granite. The inaccurate measurement of the topography results in a bad leveling and focusing performance. In this paper, an in situ method to measure the topography of a granite surface with high accuracy is present. In this method, a high-order polynomial is set up to express the topography of the granite surface. Two double-frequency laser interferometers are used to measure the tilts of the wafer stage in the X- and Y-directions. From the sampling tilts information, the coefficients of the high-order polynomial can be obtained by a special algorithm. Experiment results shows that the measurement reproducibility of the method is better than 10 nm. (c) 2006 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Isolation of high neutral lipid-containing microalgae is key to the commercial success of microalgae-based biofuel production. The Nile red fluorescence method has been successfully applied to the determination of lipids in certain microalgae, but has been unsuccessful in many others, particularly those with thick, rigid cell walls that prevent the penetration of the fluorescence dye. The conventional "one sample at a time" method was also time-consuming. In this study, the solvent dimethyl sulfoxide (DMSO) was introduced to microalgal samples as the stain carrier at an elevated temperature. The cellular neutral lipids were determined and quantified using a 96-well plate on a fluorescence spectrophotometer with an excitation wavelength of 530 nm and an emission wavelength of 575 run. An optimized procedure yielded a high correlation coefficient (R-2 = 0.998) with the lipid standard triolein and repeated measurements of replicates. Application of the improved method to several green algal strains gave very reproducible results with relative standard errors of 8.5%, 3.9% and 8.6%, 4.5% for repeatability and reproducibility at two concentration levels (2.0 mu g/mL and 20 mu g/mL), respectively. Moreover, the detection and quantification limits of the improved Nile red staining method were 0.8 mu g/mL and 2.0 mu g/mL for the neutral lipid standard triolein, respectively. The modified method and a conventional gravimetric determination method provided similar results on replicate samples. The 96-well plate-based Nile red method can be used as a high throughput technique for rapid screening of a broader spectrum of naturally-occurring and genetically-modified algal strains and mutants for high neutral lipid/oil production. (C) 2009 Published by Elsevier B.V.