14 resultados para Real-time image and video synthesis

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper studies the development of a real-time stereovision system to track multiple infrared markers attached to a surgical instrument. Multiple stages of pipeline in field-programmable gate array (FPGA) are developed to recognize the targets in both left and right image planes and to give each target a unique label. The pipeline architecture includes a smoothing filter, an adaptive threshold module, a connected component labeling operation, and a centroid extraction process. A parallel distortion correction method is proposed and implemented in a dual-core DSP. A suitable kinematic model is established for the moving targets, and a novel set of parallel and interactive computation mechanisms is proposed to position and track the targets, which are carried out by a cross-computation method in a dual-core DSP. The proposed tracking system can track the 3-D coordinate, velocity, and acceleration of four infrared markers with a delay of 9.18 ms. Furthermore, it is capable of tracking a maximum of 110 infrared markers without frame dropping at a frame rate of 60 f/s. The accuracy of the proposed system can reach the scale of 0.37 mm RMS along the x- and y-directions and 0.45 mm RMS along the depth direction (the depth is from 0.8 to 0.45 m). The performance of the proposed system can meet the requirements of applications such as surgical navigation, which needs high real time and accuracy capability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper studies the development of a real-time stereovision system to track multiple infrared markers attached to a surgical instrument. Multiple stages of pipeline in field-programmable gate array (FPGA) are developed to recognize the targets in both left and right image planes and to give each target a unique label. The pipeline architecture includes a smoothing filter, an adaptive threshold module, a connected component labeling operation, and a centroid extraction process. A parallel distortion correction method is proposed and implemented in a dual-core DSP. A suitable kinematic model is established for the moving targets, and a novel set of parallel and interactive computation mechanisms is proposed to position and track the targets, which are carried out by a cross-computation method in a dual-core DSP. The proposed tracking system can track the 3-D coordinate, velocity, and acceleration of four infrared markers with a delay of 9.18 ms. Furthermore, it is capable of tracking a maximum of 110 infrared markers without frame dropping at a frame rate of 60 f/s. The accuracy of the proposed system can reach the scale of 0.37 mm RMS along the x- and y-directions and 0.45 mm RMS along the depth direction (the depth is from 0.8 to 0.45 m). The performance of the proposed system can meet the requirements of applications such as surgical navigation, which needs high real time and accuracy capability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the real-time deformation fields are observed in two different kinds of hole-excavated dog-bone samples loaded by an SHTB, including single hole sample and dual holes sample with the aperture size of 0.8mm. The testing system consists of a high-speed camera, a He-Ne laser, a frame grabber and a synchronization device with the controlling accuracy of I microsecond. Both the single hole expanding process and the interaction of the two holes are recorded with the time interval of 10 mu s. The observed images on the sample surface are analyzed by newly developed software based on digital correlation theory and a modified image processing method. The 2-D displacement fields in plane are obtained with a resolution of 50 mu m and an accuracy of 0.5 mu m. Experimental results obtained in this paper are proofed, by compared with FEM numerical simulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optical interference method is a promising technique for measuring temperature, density, and concentration in fluids. The non-intrusive and non-invasive nature of its optical techniques to the measured section are its most outstanding features. However, the adverse experiment environment, especially regarding shaking and vibrating, greatly restricts the application of the interferometer. In the present work, an optical diagnostic system consisting of a Mach-Zehnder interferometer (named after physicists Ludwig Mach) and an image processor has been developed that increases the measuring sensitivity compared to conventional experimental methods in fluid mechanics. An image processor has also been developed for obtaining quantitative results by using Fourier transformation. The present facility has been used in observing and measuring the mass transfer process of a water droplet in EAFP protein solution under microgravity condition provided by the satellite Shi Jian No. 8.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the real-time deformation fields are observed in two different kinds of hole-excavated dog-bone samples loaded by an SHTB, including single hole sample and dual holes sample with the aperture size of 0.8mm. The testing system consists of a high-speed camera, a He-Ne laser, a frame grabber and a synchronization device with the controlling accuracy of I microsecond. Both the single hole expanding process and the interaction of the two holes are recorded with the time interval of 10 mu s. The observed images on the sample surface are analyzed by newly developed software based on digital correlation theory and a modified image processing method. The 2-D displacement fields in plane are obtained with a resolution of 50 mu m and an accuracy of 0.5 mu m. Experimental results obtained in this paper are proofed, by compared with FEM numerical simulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A scheme for the readout of a hologram recorded in bacteriorhodopsin film with high diffraction efficiency and intensity is suggested and demonstrated. Two weak coherent continuous beams function as the recording beams, and a strong light pulse is used to read the real-time hologram. The width of the readout light pulse is modulated to be short compared with the erase time of the reading beam; the time space between two adjacent pulses is ensured to be longer than the time the beams take to recover the hologram, and high diffraction efficiency and intensity (similar to 11 mW/cm(2)) can be obtained. (C) 1996 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tributyltin (TBT) is widely used as antifouling paints, agriculture biocides, and plastic stabilizers around the world, resulting in great pollution problem in aquatic environments. However, it has been short of the biomonitor to detect TBT in freshwater. We constructed the suppression subtractive hybridization library of Tetrahymena thermophila exposed to TBT, and screened out 101 Expressed Sequence Tags whose expressions were significantly up- or down-regulated with TBT treatment. From this, a series of genes related to the TBT toxicity were discovered, such as glutathione-S-transferase gene (down-regulated), plasma membrane Ca2+ ATPase isoforms 3 gene (up-regulated) and NgoA (up-regulated). Furthermore, their expressions under different concentrations of TBT treatment (0.5-40 ppb) were detected by real time fluorescent quantitative PCR. The differentially expressed genes of T thermophila in response to TBT were identified, which provide the basic to make Tetrahymena as a sensitive, rapid and convenient TBT biomonitor in freshwater based on rDNA inducible expression system. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A programmable vision chip for real-time vision applications is presented. The chip architecture is a combination of a SIMD processing element array and row-parallel processors, which can perform pixel-parallel and row-parallel operations at high speed. It implements the mathematical morphology method to carry out low-level and mid-level image processing and sends out image features for high-level image processing without I/O bottleneck. The chip can perform many algorithms through software control. The simulated maximum frequency of the vision chip is 300 MHz with 16 x 16 pixels resolution. It achieves the rate of 1000 frames per second in real-time vision. A prototype chip with a 16 x 16 PE array is fabricated by the 0.18 mu m standard CMOS process. It has a pixel size of 30 mu m x 40 mu m and 8.72 mW power consumption with a 1.8 V power supply. Experiments including the mathematical morphology method and target tracking application demonstrated that the chip is fully functional and can be applied in real-time vision applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dynamic interaction process of calmodulin with an immobilized peptide melittin was investigated in real time by surface plasmon resonance spectroscopy, and dissociation constant of the complex was calculated to be 3.37 x 10(-6) mol/L.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Layer-by-layer assembly of multilayer films of streptavidin and biotinylated antibody was completed on the streptavidin coated surface. Real-time biomolecular interaction analysis (BIA) based on surface plasmon resonance technique was used to monitor the multilayer assembly in solution continuously. The results indicate that the uniform multilayer film can be fabricated successfully based on the strong interaction between streptavidin and biotin. The mean surface mass concentration of each adsorption layer is 1. 32 ng/mm(2) for biotinylated antibody, 2. 93 ng/mm(2) for streptavidin, according to the correlation of SPR response with surface concentration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The assembly of alternating DNA and positively charged poly(dimethyldiallylammonium chloride) (PDDA) multilayer films by electrostatic layer-by-layer adsorption has been studied. Real time surface plasmon resonance (BIAcore) technique was used to characterize and monitor the formation of multilayer films in solution in real time continuously. The results indicate that the uniform multilayer can be obtained on the poly(ethylenimine) (PEI) coated substrate surface. The kinetics of the adsorption of DNA on PDDA surface was also studied by real-time BIAcore technique, and the observed rate constant was calculated using a Langmuir model (k(obs) = (1.28 +/- 0.08) x 10(-2) s(-1)).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Penaeidin from Chinese shrimp (Fenneropenaeus chinensis) has proved to be one of the most important antimicrobial peptides in the bodies of animals. The relative quantitative real-time PCR method is developed to study through time, the mRNA expression profile of penaeidin in the muscle and haemocyte tissue of Chinese shrimp infected with vibrio (Vibrio anguillarum) and WSSV (white spot syndrome virus). Research results showed that the same pathogens infection experiments produced similar gene expression profile in different tissues while different expression profiles appeared in the same tissues infected by different exterior pathogens. In vibrio infection experiments, a "U" Re expression profile resulted. Expression levels of penaeidin increased and surpassed the non-stimulated level, indicating that penaeidin from Chinese shrimp has noticeable antimicrobial activities. In WSSV infection experiments, the expression profile appeared as an inverse "U" with the expression of penaeidin gradually decreasing to below baseline level after 24 h. The expression of antimicrobial peptides gene in mRNA level in response to virus infection in shrimp showed that international mechanisms of virus to haemocytes and microbial to haemocytes are completely different. Decline of penaeidins expression levels may be due to haemocytes being destroyed by WSSV or that the virus can inhibit the expression of penaeidins by yet undiscovered modes. The expression profiles of penaeidin in response to exterior pathogen and the difference of expression profiles between vibrio and WSSV infection provided some clues to further understanding the complex innate immune mechanism in shrimp.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

De-excited dynamics of p-chlorotoluene and p-dichlorobenzene have been investigated by the femtosecond pump-probe method in a supersonic molecular beam. The yields of the parent ion and daughter ion are examined as a function of the delay time between the pump and probe laser pulses. The lifetime constants of excited p-chlorotoluene and p-dichlorobenzene are determined. Possible de-excitation mechanisms are suggested that the initially excited S-1 state is predissociative via the repulsive triplet state. The substituent effects of additional chlorine atom and methyl group are discussed. Moreover, for the first time, we observe a novel quantum beat oscillation in p-dichlorobenzene. (c) 2005 Elsevier B.V. All rights reserved.