9 resultados para Quantitative easing policy

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since reform and opening up, how much contribution has China's implementation of new agricultural policy made to agricultural output? This paper is trying to establish an agricultural policy output econometric model for doing a quantitative analysis of China's new agricultural policy. The results show that China's agricultural policies on agricultural output have an average contribution rate of about 7% since 1978, which is consistent with the OECD's basic forecast. There are obvious temporal and spatial differences. Generally speaking, we can divide the contribution of agricultural policy into three periods, which are the start-up phase from 1978 to 1991 (14 years), the stationary phase from 1992 to 2002 (11 years) and the rising phase from 2003 to 2008 (6 years). In space, the contribution of agricultural policy underwent a process from the all-low in the start-up phase, the gradual increase in the stationary phase to the all-high in the rising phase. Northern and western regions are more sensitive to policies. There are three major factors that can affect the contribution of regional agricultural policies, which are the process of national industrialization strategy, terrain and the level of local finance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mechanical model of a laser transformation hardening specimen with a crack in the middle of the hardened layer is developed to quantify the effects of the residual stress and hardness gradient on crack driving force in terms of J-integral. It is assumed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We quantitatively study the domain inversion in a RuO2:LiNbO3 crystal wafer by the digital holographic interferometry. The crystal wafer is placed into one arm of a Mach-Zehnder-type interferometer to record a series of holograms. Making use of the angular spectrum backward propagation algorithm, we reconstruct the optical wave field in the crystal plane. The extracted phase difference from the reconstructed optical wave field is a well linear function of the applied external voltage. We deduce that the linear electro-optic coefficient of the detected RuO2:LiNbO3 crystal sample is 9.1x10(-12) m/V. An unexpected phase contrast at the antiparallel domain wall is observed and the influence of the applied external voltage on it is studied in detail. Also the built-in internal field is quantitatively measured as 0.72 kV/mm. (c) 2006 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Up-converting phosphor technology (UPT)-based lateral-flow immunoassay has been developed for quantitative detection of Yersinia pestis rapidly and specifically. In this assay, 400 nm up-converting phosphor particles were used as the reporter. A sandwich immumoassay was employed by using a polyclonal antibody against F1 antigen of Y. pestis immobilized on the nitrocellulose membrane and the same antibody conjugated to the UPT particles. The signal detection of the strips was performed by the UPT-based biosensor that could provide a 980 nm IR laser to excite the phosphor particles, then collect the visible luminescence emitted by the UPT particles and finally convert it to the voltage as a signal. V-T and V-c stand for the multiplied voltage units for the test and the control line, respectively, and the ratio V-T/V-C is directly proportional to the number of Y pestis in a sample. We observed a good linearity between the ratio and log CFU/ml of Y pestis above the detection limit, which was approximately 10(4) CFU/mI. The precision of the intra- and inter-assay was below 15% (coefficient of variation, CV). Cross-reactivity with related Gram-negative enteric bacteria was not found. The UPT-LF immunoassay system presented here takes less than 30 min to perform from the sample treatment to the data analysis. The current paper includes only preliminary data concerning the biomedical aspects of the assay, but is more concentrated on the technical details of establishing a rapid manual assay using a state-of-the-art label chemistry. (c) 2006 Elsevier B.V. All rights reserved.