228 resultados para Pulse widths

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Talbot effect of a high-density grating under femtosecond laser illumination is analyzed with rigorous electromagnetic theory which is based on the Fourier decomposition and the rigorous coupled-wave analysis (RCWA). Numerical simulations show that the contrast of the Talbot images steadily decreases as the transmitted femtosecond laser pulses propagate forward and with wider spectrum width of the femtosecond laser pulses. The Talbot images of high-density gratings have much higher sensitivity of the spectrum widths of the incident laser pulses than those of the traditional low-density gratings. In experiments, the spectrums and the pulse widths of the incident pulses are measured with a frequency-resolved optical grating (FROG) apparatus. The Talbot images are detected by using a Talbot scanning near-field optical microscopy (Talbot-SNOM) technique, which are in coincidence with the numerical simulations. This effect should be useful for developing new femtosecond laser techniques and devices. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

采用面泵浦的CAMIL结构,我们研究了970 nm泵浦的Yb:YAG/YAG复合陶瓷薄片激光器,获得了连续和调Q的激光输出。在连续运转情况下,获得了最高1.05 W的激光输出,中心波长为1031 nm,后腔输出镜透射率为2%。我们同时获得了声光调Q的脉冲输出,重复频率从1 kHz到30 kHz,脉宽分别从166 ns到700 ns。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

实验研究了激光二极管阵列(LDA)侧向抽运国产Nd∶YAG陶瓷棒的准连续及被动调Q激光输出特性。该陶瓷激光器采用LDA侧面紧密环绕均匀排布的抽运结构,陶瓷棒抽运区域长度为20 mm,其总尺寸为3 mm×35 mm,掺杂原子数分数为~1%。在千赫兹准连续运转条件下,当平-平谐振腔的输出耦合镜透过率为47.3%时,获得最大平均功率23 W的1064 nm激光输出,光束发散角为4.5 mrad,斜率效率达12%。在谐振腔内插入Cr4+∶YAG晶体作为被动调Q开关,成功地实现了陶瓷激光器千赫兹重复频率调Q激光脉冲输出,当Cr4+∶YAG晶体初始透过率为60%时,输出激光脉冲宽度(半峰全宽)可窄至14.5 ns,调Q动静比约为40%。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement while drilling (MWD) has become a popular survey technology to monitor directional data, drilling data, formation evaluation data and safety data in the world. And closed loop drilling shows promise in recent years. Obviously, the method of tr

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Damage not only degrades the mechanical properties of explosives, but also influences the shock sensitivity, combustion and even detonation behavior of explosives. The study of impact damage is crucial in the vulnerability evaluation of explosives. A long-pulse low-velocity gas gun with a gas buffer was developed and used to induce impact damage in a hot pressed plastic bonded explosive. Various methods were used to detect and characterize the impact damage of the explosive. The microstructure was examined by use of polarized light microscopy. Fractal analysis of the micrographs was conducted by use of box counting method. The correlation between the fractal dimensions and microstructures was analyzed. Ultrasonic testing was conducted using a pulse through-transmission method to obtain the ultrasonic velocity and ultrasonic attenuation. Spectra analyses were carried out for recorded ultrasonic signals using fast Fourier transform. The correlations between the impact damage and ultrasonic parameters including ultrasonic velocities and attenuation coefficients were also analyzed. To quantitatively assess the impact induced explosive crystal fractures, particle size distribution analyses of explosive crystals were conducted by using a thorough etching technique, in which the explosives samples were soaked in a solution for enough time that the binder was totally removed. Impact induces a large extent of explosive crystal fractures and a large number of microcracks. The ultrasonic velocity decreases and attenuation coefficients increase with the presence of impact damage. Both ultrasonic parameters and fractal dimension can be used to quantitatively assess the impact damage of plastic bonded explosives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orthogonal designs are used to investigate the main factors when doing experiments in which pulse bias is superimposed on d.c. bias during cathodic are deposition of TiN. Pulse peak, duty cycle, frequency, direct voltage, are current and pressure all are investigated when coating TiN on HSS substrates. Roughness, surface micrograph, microhardness and thickness are tested. By analysis of variance, it is shown that pressure and frequency are the main factors. R-a and droplet density of the film with (d.c. + pulse) bias decrease. A simple explanation for the result is suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

在单脉冲激波管上,研究了1,2-二氯乙烷的热裂解.实验的激波条件为:温度区间1020 K<T<1190 K, 压力: P=0.12 MPa,实验时间τ=0.5 ms;实验气体为1,2-二氯乙烷稀释于Ar气中(3.95 mmol/L).以4-甲基-1-环己烯作为对比速率法实验的内标物,用4-甲基-1-环己烯开环反应的速率常数k=1015.3exp(-33400/T) s-1,以及从其产物的浓度推定出实验温度.经激波加热后的实验气体的终产物用气相色谱分析出主要成分为C2H3Cl,指示出主要反应通道为β消去反应.如把所有产物C2H3Cl都归于β消去反应,则可推定出表观之反应速率常数k1a=5.0×1013exp(-30000/T) s-1.对于由C-Cl键断键反应引发的链反应的可能影响做了分析研究.用了一种简便分析可推知在实验的温度范围内的低端(1020 K)链反应的影响可以忽略,而在其高端(1190 K)链反应将给出10%的终产物C2H3Cl的附加浓度,获得真实的β消去反应速率常数则必须把这部分予以扣除.经过这样的校正之后,最后得到CH2ClCH2Clβ消去反应速率常数为k1c=2.3×1013exp(-29200/T) s-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 3-D numerical model for pulsed laser transformation hardening (LTH) is developed using the finite element method. In this model, laser spatial and temporal intensity distribution, temperature-dependent thermophysical properties of material, and multi-phase transformations are considered. The influence of laser temporal pulse shape on connectivity of hardened zone, maximum surface temperature of material and hardening depth is numerically investigated at different pulse energy levels. Results indicate that these hardening parameters are strongly dependent on the temporal pulse shape. For the rectangular temporal pulse shape, the temperature field obtained from this model is in excellent agreement with analytical solution, and the predicted hardening depth is favorably compared with experimental one. It should be pointed out that appropriate temporal pulse shape should be selected according to pulse energy level in order to achieve desirable hardening quality under certain laser spatial intensity distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By solving numerically the full set of hydrodynamic equations governing the pulsation of a bubble,we show that shock waves are often absent in a stable sonoluminescing bubble. Nevertheless, for a wide range of physical parameters, a continuous compressional wave emerges and heats up the bubble, and the resulting black-body radiations have pulse heights and widths that agree with experimental data. Shock waves, being much less robust, are not essential for stable single-bubble sonoluminescence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ceramic coatings are produced on aluminum alloy by autocontrol AC pulse Plasma Electrolytic Oxidation (PEO) with stabilized average current. Transient signal gathering system is used to study the current, voltage, and the transient wave during the PEO process. SEM, OM, XRD and EDS are used to study the coatings evolution of morphologies, composition and structure. TEM is used to study the micro profile of the outer looser layer and inner compact layer. Polarization test is used to study the corrosion property of PEO coatings in NaCl solution. According to the test results, AC pulse PEO process can be divided into four stages with different aspects of discharge phenomena, voltage and current. The growth mechanism of AC PEO coating is characterized as anodic reaction and discharge sintering effect. PEO coating can increase the corrosion resistance of aluminum alloy by one order or two; however, too long process time is not necessarily needed to increase the corrosion resistance. In condition of this paper, PEO coating at 60 min is the most protective coating for aluminum alloy substrate. (C) 2008 Elsevier B.V. All fights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The inequities in health care and housing access experienced by low-income women in the United States are a continuing concern. This article addresses the interrelationships between housing and health as experienced by low-income clients so that health care practitioners can begin to build active and effective health-promoting partnerships with clients, their families, and their communities. A case study is presented that describes the actual experience of a woman living in a low-income housing development and its effect on her health and access to health care. The importance of the role of midwives in addressing the health care and advocacy needs of women in substandard housing is highlighted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulsed laser beam was used to modify surface processing for ductile iron. The microstructures of processed specimen were observed using optical microscope (OM). Nanoindentation and micro-hardness of microstructures were measured from surface to inner of sample. The experimental results show that, modification zone is consisted of light melted zone, phase transformation hardening area and transient area. The light melt area is made up of coarse dendrite crystalline with a thickness less than 20um, phase transformation hardening area mainly of laminal or acicular martensite, retained austenite and graphite, i.e. M+A prime+ G. The cow-eye microstructure around graphite sphere always is formed in phase transformation hardening area zone, which consisting of a variety structure with the distance from the surface. So, it maybe as a obvious sign distinguishing modification zone border. Finally, the microstructures evolution of laser pulse processed ductile iron was analyzed coupling with beam energy distribution in space and laser pulse heating procession characteristics. The analysis shows that energy distribution of laser pulse has an important effect on microstructure during laser pulse modified ductile iron. Multi-scale and interlace arrangement are the important features for laser pulse modified ductile iron. Of microstructure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Channeling by a train of laser pulses into homogeneous and inhomogeneous plasmas is studied using particle-in-cell simulation. When the pulse duration and the interval between the successive pulses are appropriate, the laser pulse train can channel into the plasma deeper than a single long-pulse laser of similar peak intensity and total energy. The increased penetration distance can be attributed to the repeated actions of the ponderomotive force, the continuous between-pulse channel lengthening by the inertially evacuating ions, and the suppression of laser-driven plasma instabilities by the intermittent laser-energy cut-offs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Nd:glass regenerative amplifier has been set up to generate the pumping pulse with variable pulse width for an optical parametric chirped-pulse amplification (OPCPA) laser system. Each pulse of the pulse train from a cw self-mode-locking femtosecond Ti:sapphire oscillator is stretched to approximate to300 ps at 1062 nm to be split equally and injected into a nonlinear crystal and the Nd:glass regenerative amplifier, as the chirped signal pulse train and the seed pulse train of the pumping laser system, respectively. By adjusting the cavity length of the regenerative amplifier directly, the width of amplified pulse could be varied continuously from approximate to300 ps to approximate to3 ns. The chirped signal pulse for the OPCPA laser system and the seed pulse for the pumping laser system come from the same oscillator, so that the time jitter between the signal pulse and the pumping pulse in optical parametric amplification stages could be <10 ps. (C) 2003 Society of Photo-Optical Instrumentation Engineers.