14 resultados para Prototype Verification System

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

80.00% 80.00%

Publicador:

Resumo:

智能制造装备的设计水平不高是制约我国装备制造业发展因素之一。在阐述智能制造装备特点的基础上,提出了一种基于CORBA规范的智能制造装备数字化设计与验证系统的体系结构,并探讨了实现该系统的关键技术。该系统的目的是降低智能制造设备开发成本,缩短开发周期,提高智能制造装备的设计质量。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

介绍了基于VC++开发的离线签名笔迹计算机鉴定系统,能够较好地实现签名笔迹图像多种处理效果,以满足特征提取的不同需要。他可以从复杂签名图像背景下提取出不同颜色签名笔迹,具有方便、快捷、失真小的特点。通过将笔划宽度斜度特征α加入系统进行鉴别,可有效降低识别的错误率,获得了相对较好的鉴别效果。

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The passive beam delivery system in the superficially-placed tumor therapy terminal at Heavy Ion Researc h Facility in Lanzhou (HIRFL), which includes two orthogonal dipole magnets as scanning system, a motor-driven energy degrader as range-shifter, series of ridge filters as range modulator and a multileaf collimator, is introduced in detail. The capacities of its important components and the whole system have been verified experimentally. The tests of the ridge filter for extending Bragg peak and the range shifter for energy adjustment show both work well. To examine the passive beam delivery system, a beam shaping experiment were carried out, simulating a three-dimensional (3D) conformal irradiation to a tumor. The encouraging experimental result confirms that 3D layer-stacking conformal irradiation can be performed by means of the passive system. The validation of the beam delivery system establishes a substantial basis for upcoming clinical trial for superficially-placed tumors with heavy ions in the therapy terminal at HIRFL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Digital Speckle Correlation Method (DSCM) is a useful tool for whole field deformation measurement, and has been applied to analyze the deformation field of rock materials in recent years. In this paper, a Geo-DSCM system is designed and used to analyse the more complicated problems of rock mechanics, such as damage evolution and failure procedure. A weighted correlation equation is proposed to improve the accuracy of displacement measurement on a heterogeneous deformation field. In addition, a data acquisition system is described that can synchronize with the test machine and can capture speckle image at various speeds during experiment. For verification of the Geo-DSCM system, the failure procedure of a borehole rock structure is inspected and the evolution of the deformation localization is analysed. It is shown that the deformation localization generally initializes at the vulnerable area of the rock structure but may develop in a very complicated way.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Concentrated photovoltaic systems (CPVSs) draw more and more attention because of high photovoltaic conversion efficiency, low consumption of solar cell, and low cost of power generation. However, the fallibility of the tracker in such systems has hindered their practical application for more than twenty years. The tracker is indispensable for a CPVS since only normal-incident sunlight can be focused on the solar cell chips, even a slight deviation of incident light will result in a significant loss of solar radiation, and hence a distinct decrease in electricity output. Generally, the more accurate the tracker is, the more reliable the system is. However, it is not exactly the case for a CPVS reliability, because the more accurate the tracker is, the better environment it demands. A CPVS is usually has to subjected to harsh environmental conditions, such as strong wind, heavy rain or snow, and huge changes of temperature, which leads to the invalidation of the system's high-accuracy tracker. Hence, the reliability of a CPVS cannot be improved only by enhancing the tracker's accuracy. In this paper, a novel compound concentrator, combination of Fresnel lens and photo-funnel, has been adopted in a prototype CPVS. Test results show that the compound concentrator can relax the angle tolerance from one tenth to five degrees of arc at 400 suns, which can help a CPVS endure serious environment and remain its reliability over long period. The CPVS with compound concentrator is attractive for commercial application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prototype wafer of a low power integrated CMOS Transmitter for short-range biotelemetry application has been designed and fabricated, which is prospective to be implanted in the human brain to transfer the extracted neural information to the external computer. The transmitter consists of five parts, a bandgap current regulator, a ring oscillator, a buffer, a modulator and a power transistor. High integration and low power are the most distinct criteria for such an implantable integrated circuit. The post-simulation results show that under a 3.3 V power supply the transmitter provides 100.1 MHz half-wave sinusoid current signal to drive the off-chip antenna, the output peak current range is -0.155 mA similar to 1.250 mA, and on-chip static power dissipation is low to 0.374 mW. All the performances of the transmitter satisfy the demands of wireless real-time BCI system for neural signals recording and processing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Concept mapping is a technique for visualizing the relationships between different concepts, and collaborative concept mapping is used to model knowledge and transfer expert knowledge. Because of lacking some features,existing systems can’t support collaborative concept mapping effectively. In this paper, we analysis the collaborative concept mapping process according to the theory of distributed cognition, and argue the functions effective systems ought to include. A collaborative concept mapping system should have the following features: visualization of concept map, flexible collaboration style,supporting natural interaction, knowledge management and history management. Furthermore, we describe every feature in details. Finally,a prototype system has been built to fully explore the above technologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To increase effective load, light-weight micro-propulsion system is necessary for micro-satellites. Traditional propulsion systems including large and heavy high-pressure vessels are difficult to be scaled down to fulfill the demand of micro-satellites. In this article, a novel self-pressurizing fuel tank without high-pressure gas vessel is proposed. When some liquid propellant is consumed, pressure is compensated with CO2 released by heating NH4HCO3 powder in the fuel tank. Comparing with other types of self-pressurizing liquid fuel tank, a gas generator with special and simple structure was designed to stop or continue the NH4HCO3 decomposition reaction easily, and consumed a small amount of energy to heat the powder effectively. Performance tests showed that this new prototype is very suitable for micro-thrusters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Up to now, clinical trials of heavy-ion radiotherapy for superficially placed tumors have been carried out for six times and over 60 selected patients have been treated with 80—100 MeV/u carbon ions supplied by the Heavy Ion Research Facility in Lanzhou (HIRFL) at the Institute of Modern Physics, Chinese Academy of Sciences since November, 2006. A passive irradiation system and a dose optimization method for radiotherapy with carbon-ion beams have been developed. Experimental verification of longitudinally ...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. Methods: The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an optical fiber bundle made of 8 x 16 square multiclad fibers. Signals from the insert detectors are connected to the scanner through the electronics of the disabled first ring of detectors, which permits coincidence detection between the 2 systems. Energy resolution of a detector was measured using a Ge-68 point source, and a calibrated 68Ge point source stepped across the axial field of view (FOV) provided the sensitivity profile of the system. A Na-22 point source imaged at different offsets from the center characterized the in-plane resolution of the insert system. Imaging was then performed with a Derenzo phantom filled with 19.5 MBq of F-18-fluoride and imaged for 2 h; a 24.3-g mouse injected with 129.5 MBq of F-18-fluoride and imaged in 5 bed positions at 3.5 h after injection; and a 22.8-g mouse injected with 14.3 MBq of F-18-FDG and imaged for 2 h with electrocardiogram gating. Results: The energy resolution of a typical detector module at 511 keV is 19.0% +/- 3.1 %. The peak sensitivity of the system is approximately 2.67%. The image resolution of the system ranges from 1.0- to 1.8-mm full width at half maximum near the center of the FOV, depending on the type of coincidence events used for image reconstruction. Derenzo phantom and mouse bone images showed significant improvement in transaxial image resolution using the insert device. Mouse heart images demonstrated the gated imaging capability of the device. Conclusion: We have built a prototype full-ring insert device for a small-animal PET scanner to provide higher-resolution PET images within a reduced imaging FOV. Development of additional correction techniques are needed to achieve quantitative imaging with such an insert.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A dynamic measurement system was developed by the Institute of Modern Physics (IMP) for the dipole prototype of Rapid Cycle Synchrotron (RCS) of China Spallation Neutron Source (CSNS). The repetition frequency of RCS is 25 Hz. The probe is a moving arc searching-coil, and the data acquisition system is based on the dynamic analysis modular of National Instrument. To get the error of high order harmonics of the field at basic frequency, the hardware integrator is replaced by a high speed ADC with software filter and integrator. A series of harmonic coefficients of field are used to express the varieties of dynamic fields in space and time simultaneously. The measurement system has been tested in Institute of High Energy Physics (IHEP), and the property of the dipole prototype of RCS has been measured. Some measurement results and the repeatability of system are illustrated in this paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The glass transition temperatures (T-g) of PS/PPO blends with different compositions were studied under various pressures by means of a PVT-100 analyzer. A general relation of T-g and pressure of the PS/PPO system was deduced by fitting the experimental T-g's. Couchman volume-based equation was testified with the aid of those data. It was found that the experimental T-g's do not obey the Couchman equation of glass transition temperature based on thermodynamic theory. According to our studies, the major reason of the deviation is caused by the neglect of DeltaV(mix). (C) 2001 Published by Elsevier Science Ltd.