57 resultados para Prism Yearbooks

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the rigorous results of a wide-angle laser beam scanner, obtained with the help of the vector refraction theory. Using the rigorous results, the distortion of the beam shape is discussed. The distortion to the beam varies with the different relative angles of double prisms. The scanner expands the beam in some directions while it contracts the beam in other directions. According to the conservation of energy, the distribution of the laser intensity is changed as well. (c) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we describe a wide-angle laser beam scanner and the rigorous result of the wide-angle laser beam scanner was obtained with the help of the vector refraction theory. Using the rigorous results, the distortion of the beam shape was discussed. The distortion of the beam shape is varying with the different relative angles of the double prisms. According to the conservation of the energy, the distribution of the laser intensity is changed too. (c) 2005 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the rigorous results of a wide-angle laser beam scanner, obtained with the help of the vector refraction theory. Using the rigorous results, the distortion of the beam shape is discussed. The distortion to the beam varies with the different relative angles of double prisms. The scanner expands the beam in some directions while it contracts the beam in other directions. According to the conservation of energy, the distribution of the laser intensity is changed as well. (c) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper comprehensively analyzes the distortions of a circular wedge prism with 400 mm diameter in a scanner by method of optical-mechanical-thermal integrating analysis. The structure and intensity of the prism assembly is verified and checked, and the surface deformations of the prism under gravity load, as well as the thermo-elastic distortions of the prism, are analyzed in detail and evaluated, which is finally contrasted with the measured values of Zygo Mark interferometer. The results show: the maximal distortion of the prism assembly is 10 nm magnitude and the maximal stress is 0.441 Mpa, which has much tolerance to the precision requirement of structure and the admissible stress of material; the influence of heat effect on the surface deformations of prism is proved to be far greater than the influence of gravity load, so some strict temperature-controlled measures are to be considered when the scanner is used. (c) 2006 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss coupling of ultrashort light pulses into waveguides by use of a prism waveguide coupler configuration. Theoretical analysis indicates that an extra loss induced by the short coherence times of ultrashort pulses, which has a strong effect on the reflected light and the optimum coupling condition, appears in the waveguide. Numerical simulations show that the reflectance strongly depends on the coherence times of ultrashort pulses. A method for realizing optimum coupling by compensating for the extra loss is proposed as well in this paper. A preliminary experiment of employing ultrashort pulses with different coherence times was carried out, and good agreement between theory and experiment was obtained. (c) 2006 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a novel technique for spectral shaping of femtosecond pulses employing a prism-waveguide coupler (PWC). It is demonstrated that the PWC is capable of producing a frequency-dependent loss with greater attenuation at the peak of the spectrum profile of femtosecond pulses than in the wings, which is especially useful for compensation for gain narrowing in most chirped-pulse amplification laser systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using V-prism refractometer, the refractive indices of a polyetherketone (PEK-c) guest-host polymer system were measured with the polymer in solutions. The Lorenz-Lorentz local field formalism was used in the calculation of the refractive indices of the polymers from the measured indices of the polymer solutions and the pure solvent by using V-prism refractometer. The refractive index dispersions of the polymers were obtained by fitting the measured indices of the polymers to Sellmeyer equation. The method allows for an accuracy in index of 0.7% in the determination of the polymer indices. In addition, a large difference between the indices of the polymer and the solvent, and a higher polymer volume fraction in the measured polymer solution are favorable for a high accuracy. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is predicted that large and opposite generalized Goos-Hanchen (GGH) shifts may occur simultaneously for TE and TM light beams upon reflection from an asymmetric double-prism configuration when the angle of incidence is below but near the critical angle for total reflection, which may lead to interesting applications in optical devices and integrated optics. Numerical simulations show that the magnitude of the GGH shift can be of the order of beam's width.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new crystal of aluminophosphate, AIPO(4)(.)H(2)O, is synthesized from two-batch aqueous solution under hydrothermal conditions. Three types of the crystal habits, i.e. the tetragonal double pyramid, the tetragonal prism and the plate-type tetragonal prism, are found from batch-A solution. Two types of the crystal habits, i.e. the hexagonal pyramid and the strip-type tetragonal prism, are found from batch-B solution. The change of crystal morphology is originated from the fluctuation of the synthesis conditions, such as the supersaturation, the temperature and the impurity content. It causes change of the step energies, the defect density and the step roughness, and further, change of the growth rates. Since the crystal morphology is sensitive to the mass transport mechanism, the crystal habits could be changed under the microgravity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

<正> 激光具有高度的时间和空间相干性,如果用它作为光源,可用一块渥拉斯顿稜镜(Wollaston Prism)代替纹影系统中的刀口机构,这样就形成了一台所谓的单渥拉斯顿稜镜(以下简称W稜镜)激光差分干涉仪。根据实验结果,

Relevância:

10.00% 10.00%

Publicador:

Resumo:

高强度飞秒激光脉冲的腔外压缩是获得高次谐波阿秒脉冲驱动源的必要手段。实验研究了超强超短飞秒激光脉冲在经过块状介质后的光谱展宽和色散补偿压缩现象。单脉冲能量0.26mJ,脉宽50fs的激光脉冲经透镜在空气中聚焦后再入射到块状材料上,出射脉冲光谱被展宽到接近40nm。由于在块状材料中的自聚焦效应,出射光束质量变好并保持较小的空间啁啾。利用熔融石英棱镜对补偿带有正色散的出射脉冲,最后得到〉0.1mJ,19fs的压缩脉冲。利用SPIDER装置测量了出射脉冲的脉宽和光谱相位。整个系统的能量效率大约为35%,压缩后的

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple three-axis model has been developed, which has been successfully applied to the analysis of the light transmittance in spatial incident angle and the simulation of modified formula of Malus' law for Glan-Taylor prisms. Our results indicate that the fluctuations on the cosine squared curve are due to specific misalignments between the axis of the optical system, the optical axis of the prism and the mechanical axis (rotation axis) of prism, which results in the fact that different initial relative location of the to-be-measured-prism in the testing system corresponds to different shape of Malus' law curve. Methods to get absolutely smooth curve are proposed. This analysis is available for other kinds of Glan-type prisms. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

提出了一种新思路来确定单分子的三维取向,在全内反射荧光显微成像的基础上,在显微镜的油镜上加一个水层,水和油的折射率不同造成光程差,产生离焦,利用全内反射产生隐失波激发了单分子的纵向分量,并在探测器前增加了一个分光镜,把光路分成偏振方向相互垂直的两束光,使得探测器上的光场分布包含单分子三维取向的信息。推导了隐失场激发的偶极矩光场在探测器上的光强分布表达式,通过分析偏振方向相互垂直的两束光在探测器上的不同的强度分布,来判断单分子偶极矩的三维取向。