3 resultados para Power demand curve
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
The power-time curves of growth of three strains of petroleum bacteria at different NaCl concentrations at 40.0 and 50.0 degreesC have been determined by using a 2277 Thermometric Thermal Activity Analyser. An equation of a power-time curve, ln[alphaP(K)/P(t) - 1] = ln[(alphaK - N-0)/N-0] - alphakt, was established based on the generalized logistic equation, where P(t) is the thermal power at time t, K the carrying capacity, P-K = P0K, P-0 the thermal power of one cell, N-0 the bacterial population at time zero, alpha = (k - D)/k. The method of four observed points with the same time interval was used to calculate the value of P-K. The growth rate constant k and the death rate constant D were calculated. The NaCl concentration of optimum growth rate of petroleum bacteria at 40.0 and 50.0 degreesC, respectively, have been obtained according to the curves k - D versus NaCl concentration, which are 0.26, 0.54 and 0.57 mol l(-1) for B-1, B-2 and B-3, respectively, at 50.0 degreesC, 0.26, 0.55 and 0.56 mol l(-1) for B-1, B-2 and B-3, respectively, at 40.0 degreesC. The results indicated that the effect of temperature on NaCl concentration of optimum growth rate was small. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
An arc-heated thruster of 130–800 W input power is tested in a vacuum chamber at pressures lower than 20 Pa with argon or H2–N2 gas mixture as propellant. The time-dependent arc voltage-current curve, outside-surface temperature of the anode nozzle and the produced thrust of the firing arcjet thruster are measured in situ simultaneously, in order to analyze and evaluate the dependence of thruster working characteristics and output properties, such as specific impulse and thrust efficiency, on nozzle temperature.
Resumo:
A complete set of match calculation methods for optimum sizing of PV/wind hybrid system is presented. In this method, the more accurate and practical mathematic models for characterizing PV module, wind generator and battery are adopted; combining with hourly measured meteorologic data and load data, the performance of a PV/wind hybrid system is determined on a hourly basis; by fixing the capacity of wind generators, the whole year's LPSP (loss of power supply probability) values of PV/wind hybrid systems with different capacity of PV array and battery bank are calculated, then the trade-off curve between battery bank and PV array capacity is drawn for the given LPSP value; the optimum configuration which can meet the energy demand with the minimum cost can be found by drawing a tangent to the trade-off curve with the slope representing the relationship between cost of PV module and that of the battery. According to this match calculation method, a set of match calculation programs for optimum sizing of PV/wind hybrid systems have been developed. Applying these match calculation programs to an assumed PV/wind hybrid system to be installed at Waglan island of Hong Kong, the optimum configuration and its hourly, daily, monthly and yearly performances are given. (C) 2003 Elsevier Science Ltd. All rights reserved.