21 resultados para Online measures

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The numbers of spawning sites for Chinese sturgeon have been drastically reduced since the construction of the Gezhouba Dam across the Yangtze River. This dam has blocked migration of Chinese sturgeon to their historic spawning ground causing a significant decline of the Chinese sturgeon population. We conducted a VORTEX population viability analysis to estimate the sustainability of the population and to quantify the efficiency of current and alternative conservation procedures. The model predicted the observed decline of Chinese sturgeon, resulting from the effect of the Gezhouba Dam. These simulations demonstrated the potential interest of two conservation measures: increasing spawning area and reducing predation on sturgeon eggs. The simulations also demonstrated that the actual restocking program is not sufficient to sustain sturgeon population as the artificial reproduction program induce the loss of more wild mature adults that the recruitment expected by the artificial reproduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a more general method for detecting a set of entanglement measures, i.e., negativities, in an arbitrary tripartite quantum state by local operations and classical communication. To accomplish the detection task using this method, three observers do not need to perform partial transposition maps by the structural physical approximation; instead, they only need to collectively measure some functions via three local networks supplemented by a classical communication. With these functions, they are able to determine the set of negativities related to the tripartite quantum state.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Respiration-induced target motion is a major problem in intensity-modulated radiation therapy. Beam segments are delivered serially to form the total dose distribution. In the presence of motion, the spatial relation between dose deposition from different segments will be lost. Usually, this results in over-and underdosage. Besides such interplay effects between target motion and dynamic beam delivery as known from photon therapy, changes in internal density have an impact on delivered dose for intensity-modulated charged particle therapy. In this study, we have analysed interplay effects between raster scanned carbon ion beams and target motion. Furthermore, the potential of an online motion strategy was assessed in several simulations. An extended version of the clinical treatment planning software was used to calculate dose distributions to moving targets with and without motion compensation. For motion compensation, each individual ion pencil beam tracked the planned target position in the lateral aswell as longitudinal direction. Target translations and rotations, including changes in internal density, were simulated. Target motion simulating breathing resulted in severe degradation of delivered dose distributions. For example, for motion amplitudes of +/- 15 mm, only 47% of the target volume received 80% of the planned dose. Unpredictability of resulting dose distributions was demonstrated by varying motion parameters. On the other hand, motion compensation allowed for dose distributions for moving targets comparable to those for static targets. Even limited compensation precision (standard deviation similar to 2 mm), introduced to simulate possible limitations of real-time target tracking, resulted in less than 3% loss in dose homogeneity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical trials of tumor therapy using heavy ions beam C-12 are now in progress at Institute of Modem Physics in Lanzhou. In order to achieve the precise radiotherapy with the high energy C-12 beam in active pencil beam scanning mode, we have developed an ionization chamber(IC) as an online monitor for beam intensity and also a dosimeter after calibration. Through the choosing of working gas and voltage, optimizing of the electrics and the read-out system, calibrating the linearity, the detector system provide us one of the simple and highly reliable way to monitoring the beam during the active pencil beam scanning treatments. The measurement results of this detector system show that it could work well under the condition of high energy C-12 beam in active pencil beam scanning mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerous measures are used in the literature to describe the grain-size distribution of sediments. Consideration of these measures indicates that parameters computed from quartiles may not be as significant as those based on more rigorous statistical concepts. In addition, the lack of standardization of descriptive measures has resulted in limited application of the findings from one locality to another. The use of five parameters that serve as approximate graphic analogies to the moment measures commonly employed in statistics is recommended. The parameters are computed from five percentile diameters obtained from the cumulative size-frequency curve of a sediment. They include the mean (or median) diameter, standard deviation, kurtosis, and two measures of skewness, the second measure being sensitive to skew properties of the "tails" of the sediment distribution. If the five descriptive measures are listed for a sediment, it is possible to compute the five percentile diameters on which they are based (phi 5 , phi 16 , phi 50 , phi 84 , and phi 95 ), and hence five significant points on the cumulative carve of the sediment. This increases the value of the data listed for a sediment in a report, and in many cases eliminates the necessity of including the complete mechanical analysis of the sediment. The degree of correlation of the graphic parameters to the corresponding moment measures decreases as the distribution becomes more skew. However, for a fairly wide range of distributions, the first three moment measures can be ascertained from the graphic parameters with about the same degree of accuracy as is obtained by computing rough moment measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

National Key Technology RD Program [2006BAD03A02]