33 resultados para Measurement range

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

70.00% 70.00%

Publicador:

Resumo:

A white light interferometer is developed to measure the distributed polarization coupling in high-birefringence polarization-maintaining fibers (PMFs). Usually the birefringence dispersion between two orthogonal eigenmodes of PMFs is neglected in such systems. Theoretical analysis and experimental results show that the birefringence dispersion becomes a nonnegligible factor in a long-fiber test. Significant broadening of interferograms and loss of longitudinal coherence are observed. The spatial resolution and measurement sensitivity of the system decrease correspondingly. Optimum spectrum width selection is presented for better spatial resolution and measurement range. c 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A white light interferometer is developed to measure the distributed polarization coupling in high-birefringence polarization-maintaining fibers (PMFs). Usually the birefringence dispersion between two orthogonal eigenmodes of PMFs is neglected in such systems. Theoretical analysis and experimental results show that the birefringence dispersion becomes a nonnegligible factor in a long-fiber test. Significant broadening of interferograms and loss of longitudinal coherence are observed. The spatial resolution and measurement sensitivity of the system decrease correspondingly. Optimum spectrum width selection is presented for better spatial resolution and measurement range. c 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective speckle from a stick-on foil is a new approach to applying the objective white light speckle method to in-plane displacement measurements. By a relatively easy technique a thin aluminum foil is mounted onto the specimen surface and a random grating is scratched onto it, yielding high reflectance and fine optical details. After double exposure by a direct recording system without using a lens, the resulting holographic film possesses a broad spatial spectrum and displacement information. Full-field contour maps of equal displacement can be obtained that are of good contrast and high sensitivity and that have a large adjustable measurement range. The method can be applied to practical engineering problems for both plane and developable curved surfaces.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

现有的半导体激光干涉仪存在测量精度与测量范围的矛盾。本文提出一种新的实时位移测量半导体激光干涉仪,并分析了干涉仪的测量原理。首先提出一种新的解相算法,它通过两路实时相位探测电路从干涉信号中得到待测量相位,消除了光强波动、初始光程差、电路放大倍数、调制深度、Bessel函数等参数对测量精度的影响,提高了测量精度。其次,提出一种扩大测量范围的技术,并用解包裹电路得到真实相位和待测量的位移, 将测量范围从半个波长提高到几个波长。在实验中,测得喇叭的峰峰值为2361.7nm,重复测量精度为2.56nm,测量时间为

Relevância:

60.00% 60.00%

Publicador:

Resumo:

提出了一种基于人工神经网络的全光纤化大量程实时距离干涉测量仪.采用双正弦相位调制方法,即通过同时调制半导体激光器的波长和干涉仪的光程差实现外差测量。为了扩大干涉仪的测量范围和消除输出信号中的交叉敏感,采用人工神经网络进行信号处理,把两路经过初步解调的干涉信号作为输入样本,物体距离的实际值作为输出样本,对神经网络进行训练,以使其具有良好的推广能力.实验结果表明神经网络的使用不仅扩大了距离的测量范围而且提高了测量精度.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

高精度时间间隔测量单元(TIU)是星载激光测距仪的关键部件。基于现场可编程门阵列(FPGA)研制出了满足星载要求的高精度、高集成度时间间隔测量单元。该单元采用数字计数法结合数字延迟线插入法的技术,在0.5~10 km的测量距离范围内,时间分辨率为500 ps。通过地面检测,在全程范围内保持了良好的线性度,标准偏差小于270 ps。该单元同时具备测量脉冲回波宽度的能力,可以获取目标的脉冲展宽信息。由于单元选用的元器件都具有航天产品性能,因此其设计和技术指标可满足星载激光测距仪的应用。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A practical package technique for temperature independent Fiber Bragg grating sensor is proposed. A uniform strength cantilever with two FBG attached on the upper and lower surfaces was utilized as the key element. By detecting two wavelengths differential output, the applied force can be obtained and temperature effects can be eliminated. Experiment results show the sensor has linear response and output signal uctuates less than 12pm as temperature changes from -10 degrees C to 50 degrees C. The maximum thermal error is less than 0.3% of the full measurement range.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction of small amount of CF4 premixed in the test gas. The final product C2F4 is used as the temperature indicator, which is sampled and detected by a gas chromatography in the experiment. The detected concentration of C2F4 is correlated to the temperature of the reflected shock wave with the initial pressure P-1 and test time tau as parameters in the temperature range 3 300 K < T < 5 600 K, pressure range 5 kPa < P1 <12 kPa and tau similar or equal to 0.4 ms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Turbidity measurement for the absolute coagulation rate constant of suspensions has been extensively adopted because of its simplicity and easy implementation. A key factor to derive the rate constant from experimental data is how to theoretically evaluate the so-called optical factor involved in calculating the extinction cross section of doublets formed in the aggregation. In a previous paper, we have shown that compared with other theoretical approaches, the T-matrix method provides a robust solution to this problem and is effective in extending the applicability range of the turbidity methodology as well as increasing measurement accuracy. This paper will provide a more comprehensive discussion about the physical insight of using the T-matrix method in turbidity measurement and associated technical details. In particular, the importance of ensuring the correct value for the refractive indices for colloidal particles and the surrounding medium used in the calculation is addressed because the indices generally vary with the wavelength of the incident light. The comparison of calculated results with experiments shows that the T-matrix method can correctly calculate optical factors even for large particles, whereas other existing theories cannot. In addition, the calculated data of the optical factor by the T-matrix method for a range of particle radii and incident light wavelengths are listed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The refractive indices of particles and dispersion medium are important parameters in many colloidal experiments using optical techniques, such as turbidity and light scattering measurements. These data are in general wavelength-dependent and may not be available at some wavelengths fitting to the experimental requirement. in this Study we present a novel approach to inversely determine the refractive indices of particles and dispersion medium by examining the consistency of measured extinction cross sections of particles with their theoretical values using a series of trial values of the refractive indices. The colloidal suspension of polystyrene particles dispersed in water was used as an example to demonstrate how this approach works and the data obtained via such a method are compared with those reported in literature, showing a good agreement between both. Furthermore, the factors that affect the accuracy of measurements are discussed. We also present some data of the refractive indices of polystyrene over a range of wavelengths smaller than 400 nm that have been not reported in the available literature. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The existing theories dealing with the evaluation of the absolute coagulation rate constant by turbidity measurement were experimentally tested for different particle-sized (radius = a) suspensions at incident wavelengths (lambda) ranging from near-infrared to ultraviolet light. When the size parameter alpha = 2 pi a/lambda > 3, the rate constant data from previous theories for fixed-sized particles show significant inconsistencies at different light wavelengths. We attribute this problem to the imperfection of these theories in describing the light scattering from doublets through their evaluation of the extinction cross section. The evaluations of the rate constants by all previous theories become untenable as the size parameter increases and therefore hampers the applicable range of the turbidity measurement. By using the T-matrix method, we present a robust solution for evaluating the extinction cross section of doublets formed in the aggregation. Our experiments show that this new approach is effective in extending the applicability range of the turbidity methodology and increasing measurement accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our previous studies have shown that the determination of coagulation rate constants by turbidity measurement becomes impossible for a certain operating wavelength (that is, its blind point) because at this wavelength the change in the turbidity of a dispersion completely loses its response to the coagulation process. Therefore, performing the turbidity measurement in the wavelength range near the blind point should be avoided. In this article, we demonstrate that the turbidity measurement of the rate constant for coagulation of a binary dispersion containing particles of two different sizes (heterocoagulation) presents special difficulties because the blind point shifts with not only particle size but also with the component fraction. Some important aspects of the turbidity measurement for the heterocoagulation rate constant are discussed and experimentally tested. It is emphasized that the T-matrix method can be used to correctly evaluate extinction cross sections of doublets formed during the heterocoagulation process, which is the key data determining the rate constant from the turbidity measurement, and choosing the appropriate operating wavelength and component fraction are important to achieving a more accurate rate constant. Finally, a simple scheme in experimentally determining the sensitivity of the turbidity changes with coagulation over a wavelength range is proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The feasibility of direct measurement of temperature in shock-loaded, nonmetallic solids within microseconds using a foil thermocouple of 200 Å thickness has been studied over a range of pressure from 0.5 to 4 GPa. The foil thermocouple and thermopile (200 Å thickness) were designed and used to measure the temperature rise in shock-compressed polymethylmethacrylate (PMMA). The method used to manufacture the gauges is spelled out in detail in this paper. The results agree with calculated PMMA temperatures when the shock pressure is below 2.2 GPa. Above this pressure the measured temperature rise is far higher than the calculated values. This result appears to be very similar to that obtained earlier by Bloomquist and Sheffield.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A high-voltage measuring system, employing a quartz Pockels cell, is described. The system is capable of a large voltage range, a fast response time (ns), a high SNR, an excellent accuracy, a good linearity, and high reliability. Furthermore, the Pockels cell can be isolated from ground potential. Equally important, the detection system can be isolated from sources of electrical noise present in, for example, fast discharges.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At the shock velocity range of 7~9km/s, the variations of electron density behind strong normal shock waves are measured in a low-density shock tube by using the Langmuir electrostatic probe technique. The electron temperature, calculated based on Park’s three-temperature model, is used in interpreting the probe current data. The peak electron densities determined in the present experiment are shown to be in a good agreement with those predicted by Lin’s calculation. The experimentally obtained ratios of the characteristic ionization distance to the mean free path of freestream ahead of the shock wave are found to be in a good agreement with the existing experiments and Park’s calculation.