2 resultados para MYOCARDIAL REVASCULARIZATION
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
The Tie-2 receptor has been shown to play a role in angiogenesis in atherosclerosis. The conventional method assaying the level of soluble Tie-2 (sTie-2) was ELISA. However, this method has some disadvantages. The aims of this research are to establish a more simple detection method, the optical protein-chip based on imaging ellipsomtry (OPC-IE) applying to Tie-2 assay. The sTie-2 biosensor surface on silicon wafer was prepared first, and then serum levels of sTie-2 in 38 patients with AMI were measured on admission (day 1), day 2, day 3 and day 7 after onset of chest pain and 41 healthy controls by ELISA and OPC-IE in parallel. Median level of sTie-2 increased significantly in the AMI patients when compared with the controls. Statistics showed there was a significant correlation in sTie-2 results between the two methods (r=0.923, P0.01). The result of this study showed that the level of sTie-2 increased in AMI, and OPC-IE assay was a fast, reliable, and convenient technique to measure sTie-2 in serum.
Resumo:
Previous in vivo study demonstrated that beta gamma-CAT, a newly identified non-lens beta gamma-crystallin and trefoil factor complex from frog Bombina maxima skin secretions, possessed potent lethal toxicity on mammals resulted from hypotension and cardi