4 resultados para Lidocaine

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fast analysis of ofloxacin and lidocaine, as bactericide and analgesic or anesthetics, is of clinic importance for understanding the patient's medical process. This paper presented a high throughput, simple analysis method of lidocaine and ofloxacin by capillary electrophoresis coupled with electrochemiluminescence (ECL) using porous etched joint. To shorten the analysis time and to improve the analytical performance, a capillary with 10 cm in length was used as the separation channel. The cyclic voltammograms of Ru(bpy)(3)(2+) with different capillary length at same field strength showed that the porous etched joint eliminated the effect of electrophoretic current on the ECL detection. Following micro total analysis systems (muTAS), some advantages of which this approach has, the fabrication of channel in chip was not needed. Compared with capillary electrophoresis with 40-cm-long capillary, the high sample throughput and low zone broadening may be the main advantage of the present system. Under optimal condition, the detection limits of lidocaine and ofloxacin based on peak height were 3.0 x 10(-8) and 5.0 x 10(-7) mot L-1 and a 60 h(-1) of sampling frequency was obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tramadol and lidocaine, used as analgesic and local anesthetic in surgery, are partly excreted by kidney. For the first time, we developed a simple and sensitive method, based on capillary electrophoresis with electrochemiluminescence (ECL) detection by end column mode without joint to monitor tramadol and lidocaine in urine. To eliminate the influence of ionic strength of urine sample, analytes were extracted by ether. Tripropylamine (TPA) was used as internal standard. ne recoveries of tramadol and lidocaine were between 94% and 97% at different levels. The method exhibited the linear range for the tramadol and lidocaine from 1.0 X 10(-7) to 1.0 X 10(-4) mol/L with correlation efficient of 0.998. The relative standard deviation (RSD) was 2.9% and 2.7% (n = 8) for tramadol and lidocaine, respectively. The limit of detection (LOD) was 6.0 x 10(-8) mol/L and 4.5 x 10(-8), mol/L (S/N = 3) for tramadol and lidocaine, respectively. The application for detecting tramadol and lidocaine in urine of patients showed that the method was valuable in clinical and biochemical laboratories for detecting tramadol, lidocaine and other tertiary amine pharmaceuticals for various purpose, such as metabolism investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lidocaine transfer across the water/1,2-dichloroethane and the water/nitrobenzene interfaces has been investigated by chronopotentiometry with linear current scanning and cyclic voltammetry. The irreversible hydrolysis occurring in the phase transfer of dicaine at the water/nitrobenzene interface is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

capillary electrophoresis (CE) is characterized. A 300 mum diameter Pt working electrode was used to directly couple with a 75 mum inner diameter separation capillary without an electric field decoupler. The hydrodynamic cyclic voltammogram (CV) of Ru(bpy)(3)(2+) showed that electrophoretic current did not affect the ECL reaction. The presence of high-voltage (HV) field only resulted in the shift of the ECL detection potential. The distance of capillary to electrode was an important parameter for optimizing detection performance as it determined the characteristics of mass transport toward the electrode and the actual concentration of Ru(bpy)(3)(2+) in the detection region. The optimum distance of capillary to electrode was decided by the inner diameter of the capillary, too. For a 75 mum capillary, the working electrode should be placed away from the capillary outlet at a distance within the range of 20-260 mum. The effects of pH value of ECL solution and molecular structure of analytes on peak height and theoretical plate numbers were discussed. Using the 75 mum capillary, under the optimum conditions, the method provided a linear range for tripropylamine (TPA) between 1 x 10(-10) and 1 X 10(-5) mol/L with correlation coefficient of 0.998. The detection limit (signal-to-noise ratio S/N = 3) was 5.0 x 10(-11) mol/L. The relative standard deviation in peak height for eight consecutive injections was 5.6%. By this new technique lidocaine spiked in a urine sample was determined. The method exhibited the linear range for lidocaine from 5.0 x 10(-8) to 1.0 X 10(-5) mol/L with correlation efficient of 0.998. The limit of detection (S/N = 3) was 2.0 x 10(-1) mol/L.