164 resultados para Laser resonance ionization

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report for the first time the proper conditions to observe Autler-Townes splitting (ac-Stark splitting) from vibrationally coherent states belonging to the different electronic terms of a diatomic molecule. Wave packet dynamics simulations demonstrate that such a process is feasible by multiphoton resonance ionization of the molecule Na-2 with a single ultrashort intense laser pulse. With the ultrahigh time resolution of a femtosecond laser pulse, one can directly measure the absolute value of the transition dipole moment between any kinds of molecular states by this kind of Autler-Townes splitting, which is a function of the internuclear distance R.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this report, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to study the binding interactions between calmodulin and two target peptides (melittin and substance P). Various matrix conditions were tested and the less acidic matrix DHAP and THAP were found to favor the survival of the intact calcium-calmodulin as well as the calmodulin-peptide complexes. However, the application of direct MALDI-MS to detect the intact complexes turned out to be very difficult due to the dissociation of the complexes and the formation of nonspecific aggregates. In contrast, the specific binding of the target peptides to calmodulin could be easily deduced using intensity-fading (IF) MALDI-MS. Compared with the nonbinding control, clear reduction in the ion abundances of the target peptides was observed with the addition of calmodulin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Desorption/ionization on silicon mass spectrometry (DIOS-MS) is a matrix-free technique that allows for the direct desorption/ionization of low-molecular-weight compounds with little or no fragmentation of analytes. This technique has a relatively high tolerance for contaminants commonly found in biological samples. DIOS-MS has been applied to determine the activity of immobilized enzymes on the porous silicon surface. Enzyme activities were also monitored with the addition of a competitive inhibitor in the substrate solution. It is demonstrated that this method can be applied to the screening of enzyme inhibitors. Furthermore, a method for peptide mapping analysis by in situ digestion of proteins on the porous silicon surface modified by trypsin, combined with matrix-assisted laser desorption/ionization-time of flight-MS has been developed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peptide mass mapping analysis, utilizing a regenerable enzyme microreactor with metal-ion chelated adsorption of enzyme, combined with matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) was developed. Different procedures from the conventional approaches were adopted to immobilize the chelator onto the silica supports, that is, the metal chelating agent of iminodiacetic acid (IDA) was reacted with glycidoxypropyltrimethoxysilane (GLYMO) before its immobilization onto the inner wall of the fused-silica capillary pretreated with NH4HF2. The metal ion of copper and subsequently enzyme was specifically adsorbed onto the surface to form the immobilized enzyme capillary microreactor, which was combined with MALDI-TOF-MS to apply for the mass mapping analysis of nL amounts of protein samples. The results revealed that the peptide mapping could routinely be generated from 0.5 pmol protein sample in 15 min at 50degreesC, even 20 fmol cytochrome c could be well digested and detected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Porous silicon powder and silica gel particles have been applied as inorganic matrices for the analysis of small molecules in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOFMS). In contrast to conventional MALDI-TOFMS, the signal interference of low-molecular analytes by the matrix has been eliminated. Almost no fragmentations of the analytes were observed. Effects of various factors, such as the particle and pore size, the suspending solution, and sample preparation procedures, on the intensity of mass spectra have been investigated. The pore structure of the inorganic matrix and penetration of the analytes into the pores must be optimized for effective desorption and ionization of the analytes. Matrices (DHB and HCCA) were covalently bound to silica gel for improvement of spectrum intensity. Copyright (C) 2001 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and high-throughput method for the identification of disulfide-containing peptides utilizing peptide-matrix adducts is described. Some commonly used matrices in MALDI mass spectrometry were found to specifically react with sulfhydryl groups within peptide, thus allowing the observation of the peptide-matrix adduct ion [M + n + n' matrix + H](+) or [M + n + n' matrix + Na](+) (n = the number of cysteine residues, n' = 1, 2, ..., n) in MALDI mass spectra after chemical reduction of disulfide-linked peptides. Among several matrices tested, alpha-cyano-4-hydroxycinnamic acid (CHCA, molecular mass 189 Da) and alpha-cyano-3-hydroxycinnamic acid (3-HCCA) were found to be more effective for MALDI analysis of disulfide-containing peptides/proteins. Two reduced cysteines involved in a disulfide bridge resulted in a mass shift of 189 Da per cysteine, so the number of disulfide bonds could then be determined, while for the other matrices (sinapinic acid, ferulic acid, and caffeic acid), a similar addition reaction could not occur unless the reaction was carried out under alkaline conditions. The underlying mechanism of the reaction of the matrix addition at sulfhydryl groups is proposed, and several factors that might affect the formation of the peptide-matrix adducts were investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The molecular weight of recombinant hirudin ( rHV-2) was determined rapidly by matrix-assisted laser desorption/ionization time of fight mass spectrometry (MALDI-TOF-MS). The effects of the three types of matrixes were compared and discussed, alpha-cynao-4-hydroxycinnamic acid was proved to be the best matrix. It showed that MALDI-TOF-MS was superior to the traditional method of molecular weight determination of the biological macromolecules. The mass spectrum data proved that the primary structure of rHV-2 was correct and there was no amino acid deletion, mutation and modification in its expression, refolding and purification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Monodispersed polyaniline oligomers was studied by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS), It is found that MALDI-TOF-MS is not only a direct, accurate and rapid tool for the analysis of monodispersed polyaniline oligomers, but also a useful technique for the design of synthetic route.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MAIDI-TOF-MS) was used for analysis of poly(arylene phosphonate) cyclic oligomers. A comparison was made by using 1,8,9-dithranol, 2,5-dihydroxybenzoic acid and retinoic acid as the matrix. The result showed that the retinoic acid produced the strongest ion signals under the conditions used. Different salts of metals were used as the cationization agents to examine the effect on the cyclic oligomers. It was found that the salts could produce metal-cyclic oligomer cation spectra and lithium was the stronger one than those of silver so, the suitable matrix and cationization agent for the new cyclic oligmer were obtained. They were very effective for the analysis of poly(arylene phosphonate) cyclic oligomer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used to study a series of synthetic cationic porphyrins as the perchlorate and bromide salts. This work presents the analytical results for the porphyrins obtained using 2,5-dihydroxybenzoic acid (DHB) and 1,8,9-anthratriol as matrices. The selective use of matrix affects ion formation from these porphyrins. By using DHB as the matrix, we not only observed [M - nCIO(4)](+) (n = 1-4) ions, but also obtained [2M - nCIO(4)](+) (n = 2-7) ions from the synthetic cationic porphyrins. The space volume of the side chains (R groups) and the nature of the anions (Br- or CIO4-) affected the relative importance of monomeric and dimeric ions of the porphyrin. The possible mechanisms of desorption and ionization of these cationic porphyrins were also considered in this study. MALDI-TOFMS proved to be a very useful method for obtaining structural information on these synthetic cationic porphyrins. Copyright (C) 1999 John Whey & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cyclic aryletherketone( sulfone) oligomers containing hexafluoroisopropylidene unit were characterized by matrix-assisted laser desorption ionization time-of-night mass spectrometry(MALDI-TOF-MS) using Na+ and Ag+ as cationization agents. The affinities of cyclic oligomers to the cation were studied. The analysis result showed that 1,8,9-dithranol, in the presence of silver trifluoroacetate, was very effective for the characterization of cyclic arylether ketone ( sulfone) containing hexafluoroisopropylidene unit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purity and molecular weight of calmodulin have been determined by means of matrix-assisted laser desorption/ionization time of flight mass spectrometry, and the results have been discussed. The experimental results demonstrate that this method is high sensitive and rapid as compared with other traditional methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). The homogeneities and molecular weights of three arginine esterases from snake venom, which possessing therapeutic use in myocardial infarction, were determined and compared, MALDI-TOF-MS is possessed of high accuracy, high sensitivity and rapidity. MALDI-TOF-MS and sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) can provide complementary and confirmatory results information. MALDI-TOF-MS can be directly used as an important method for the purification of snake venom complexes successfully.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used to analyze two enzymes, phospholipase AZ and fibrinolytic enzyme isolated from Chinese Agkistrodon blomhoffii Ussurensis venom. Using sinapinic acid as the matrix, positive ion mass spectra of the enzymes were obtained, In addition to the dominant protein [M+H](+) ions, multimeric and multiply charged ions were also observed in the mass spectra, The higher the concentration of the enzymes, the more multiply charged polymer and multimeric ions were detected, Our results indicate that MALDI-TOFMS can provide a rapid and accurate method for molecular weight determination of snake venom enzymes, Mass accuracies of 0.1 and 0.3 % were achieved by analysis of highly dialyzed phospholipase A2 and fibrinolytic enzyme, and these results are much better than those obtained using sodium dodecyl sulfate-palyacrylamide gel electrophoresis. MALDI-TOFMS thus provides a reliable method to determine the purity and molecular weight of these enzymes, which are of potential use as therapeutants, Copyright (C) 1999 John Wiley & Sons, Ltd.