91 resultados para Large-aperture receiver

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose an optical apparatus enabling the measurement of spherical power, cylindrical power, and optical center coordinates of ophthalmic lenses. The main advantage of this new focimeter is to provide a full bidimensional mapping of the characteristics of ophthalmic glasses. This is made possible thanks to the use of a large-area and high-resolution position-sensitive detector. We describe the measurement principle and present some typical mappings, particularly for progressive lenses. We then discuss the advantages in terms of speed and versatility of such a focimeter for the measurement of complex lens mappings. (C) 2002 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present a method of image-speckle contrast for the nonprecalibration measurement of the root-mean-square roughness and the lateral-correlation length of random surfaces with Gaussian correlation. We use the simplified model of the speckle fields produced by the weak scattering object in the theoretical analysis. The explicit mathematical relation shows that the saturation value of the image-speckle contrast at a large aperture radius determines the roughness, while the variation of the contrast with the aperture radius determines the lateral-correlation length. In the experimental performance, we specially fabricate the random surface samples with Gaussian correlation. The square of the image-speckle contrast is measured versus the radius of the aperture in the 4f system, and the roughness and the lateral-correlation length are extracted by fitting the theoretical result to the experimental data. Comparison of the measurement with that by an atomic force microscope shows our method has a satisfying accuracy. (C) 2002 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

New parasitic lasing suppression techniques are developed and high gain amplification is demonstrated in a petawatt level Ti:sapphire amplifier based on the chirped pulse amplification (CPA) scheme. Cladding the large aperture Ti: sapphire with refractive-index matched liquid doped with absorber suppresses the transverse lasing. The acousto-optic programmable dispersive filter (AOPDF) is used to realize side-lobe suppression in the temporal profile of the compressed pulse. The 800 nm laser output with peak power of 0.89 PW and pulse width of 29.0 fs is demonstrated. (c) 2007 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The resolution and classical noise in ghost imaging with a classical thermal light are investigated theoretically. For ghost imaging with a Gaussian Schell model source, the dependences of the resolution and noise on the spatial coherence of the source and the aperture in the imaging system are discussed and demonstrated by using numerical simulations. The results show that an incoherent source and a large aperture will lead to a good image quality and small noise.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We propose a novel highly sensitive wave front detection method for a quick check of a flat wave front by taking advantage of a non-zero-order pi phase plate that yields a non-zero-order diffraction pattern. When a light beam with a flat wave front illuminates a phase plate, the zero-order intensity is zero. When there is a slight distortion of the wave front, the zero-order intensity increases. The ratio of first-order intensity to that of zero-order intensity is used as the criterion with which to judge whether the wave front under test is flat, eliminating the influence of background light. Experimental results demonstrate that this method is efficient, robust, and cost-effective and should be highly interesting for a quick check of a flat wave front of a large-aperture laser beam and adaptive optical systems. (c) 2005 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

在星间激光通信中,涉及对大口径衍射极限激光波面的检测,为保证测量精度,必须严格控制波面十涉仪镜子的自重和温度变形。采用有限元方法对大型干涉仪镜子在不同支承方式下的表面变形进行了分析,结果表明,接触角为180°的钢带支承是较好的支承方式,反射镜表面变形峰-谷(P-V)值仅为1.35nm,均方根(RMS)值为0.363nm根据这一结论,设计了一个同定支承点与浮动支承相结合的超静定钢带支承结构。在该结构下,分析了镜子轴向、径向、周向的温度梯度效应,分析数据表明,镜子的热弹性变形远大于自重变形,建议采取一定的温控

Relevância:

80.00% 80.00%

Publicador:

Resumo:

采用蜗轮蜗杆驱动调整机构、使用同步带安装标准镜片方式、正交十字导轨支撑等可有效提高光学精密检测系统中大口径干涉仪装置的镜面面形质量、稳定性和调节准确度,从理论上介绍了蜗轮蜗杆驱动机构等设计原理及其基本公式,并从实验上验证了这些机构对光学精密检测系统稳定性的影响.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

从靶场反射镜架模块的机械结构设计布局所需几何空间的角度出发,根据大口径、列阵器件的特殊要求,给出符合“神光Ⅲ”装置总体技术要求的ICF靶场光束口径与列阵间隔之间的关系,得出靶场△纵、△横应满足的公式.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

控制由机械装夹方式所引入的波前畸变以提高惯性约束聚变(ICF)输出光束的质量,是在大口径钕玻璃片主放大器结构设计中必须考虑的。提出了一种新的有限元变形结果与光学元件面形畸变之间的数据处理方式,并与传统方式进行了对比。基于新的数据处理接口,利用光机集成分析方法对大口径八边形钕玻璃片的支撑系统结构设计参数进行优化。优化的结果保证了由支撑系统引起的透过波前畸变小于十分之一波长,同时波前畸变与设计参数变动的相关性最小。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

在传统哈特曼检验法基础上研制成功一种扫描型哈特曼检测新装置。可对最大口径为Ф300mm的聚焦镜在全口径范围内进行采样测量。该检测装置由大口径标准平行光管、扫描式哈特曼光阑、被俭聚焦镜、CCD摄像机及计算机组成。在水平和垂直两个径向上开有等间距排列且相互错开半个间距的小孔。并且在步进电机的驱动下绕光轴旋转。可对被检聚焦镜进行全口径连续采样。对有效口径为夺154mm的斐索平面干涉仪非球面准直物镜的球差及焦斑能量集中度进行了测量。进而由球差计算得到了波像差。并用干涉法对该准直物镜进行了测量。球差的理论值与测量值

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new type of wave-front analysis method for the collimation testing of laser beams is proposed. A concept of wave-front height is defined, and, on this basis, the wave-front analysis method of circular aperture sampling is introduced. The wave-front height of the tested noncollimated wave can be estimated from the distance between two identical fiducial diffraction planes of the sampled wave, and then the divergence is determined. The design is detailed, and the experiment is demonstrated. The principle and experiment results of the method are presented. Owing to the simplicity of the method and its low cost, it is a promising method for checking the collimation of a laser beam with a large divergence. © 2005 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fabrication of very-small-aperture lasers is demonstrated, and their performance is analyzed. Because of strong optical feedback caused by a gold film on the front facet of the laser, its behavior changes: The threshold current decreases, the density of light inside the laser diode and the redshift effect of the spectra are enhanced, and the laser diode's lifetime is shorter than that of common laser diodes with large driving current. (c) 2005 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reliable turbulent channel flow databases at several Reynolds numbers have been established by large eddy simulation (LES), with two of them validated by comparing with typical direct numerical simulation (DNS) results. Furthermore, the statistics, such as velocity profile, turbulent intensities and shear stress, were obtained as well as the temporal and spatial structure of turbulent bursts. Based on the LES databases available, the conditional sampling methods are used to detect the structures of burst events. A method to deterimine the grouping parameter from the probability distribution function (pdf) curve of the time separation between ejection events is proposed to avoid the errors in detected results. And thus, the dependence of average burst period on thresholds is considerably weakened. Meanwhile, the average burst-to-bed area ratios are detected. It is found that the Reynolds number exhibits little effect on the burst period and burst-to-bed area ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Load/Unload Response Ratio (LURR) method is proposed for short-to-intermediate-term earthquake prediction [Yin, X.C., Chen, X.Z., Song, Z.P., Yin, C., 1995. A New Approach to Earthquake Prediction — The Load/Unload Response Ratio (LURR) Theory, Pure Appl. Geophys., 145, 701–715]. This method is based on measuring the ratio between Benioff strains released during the time periods of loading and unloading, corresponding to the Coulomb Failure Stress change induced by Earth tides on optimally oriented faults. According to the method, the LURR time series usually climb to an anomalously high peak prior to occurrence of a large earthquake. Previous studies have indicated that the size of critical seismogenic region selected for LURR measurements has great influence on the evaluation of LURR. In this study, we replace the circular region usually adopted in LURR practice with an area within which the tectonic stress change would mostly affect the Coulomb stress on a potential seismogenic fault of a future event. The Coulomb stress change before a hypothetical earthquake is calculated based on a simple back-slip dislocation model of the event. This new algorithm, by combining the LURR method with our choice of identified area with increased Coulomb stress, is devised to improve the sensitivity of LURR to measure criticality of stress accumulation before a large earthquake. Retrospective tests of this algorithm on four large earthquakes occurred in California over the last two decades show remarkable enhancement of the LURR precursory anomalies. For some strong events of lesser magnitudes occurred in the same neighborhoods and during the same time periods, significant anomalies are found if circular areas are used, and are not found if increased Coulomb stress areas are used for LURR data selection. The unique feature of this algorithm may provide stronger constraints on forecasts of the size and location of future large events.