10 resultados para LIBS

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

激光诱导击穿光谱(LIBS)已成功地运用于固体、液体、气体样品中微量元素的测量以及微生物、细菌等的鉴别分析上,而在植物样品上面的应用则是一个较新的课题。该实验用纳秒Nd:YAG激光器击穿真空冻干的土豆、百合样品,用光纤光谱仪测量了其LIBS光谱。通过鉴别、分析LIBS光谱,得到了这两种样品中微量元素的成分。并且对土豆干和百合干中Ca,Na,K,Fe,Al,Mg六种金属元素典型谱线的强度进行了统计分析,并由此得到了样品中这六种微量元素含量的对比情况。实验结果表明土豆干中的Ca和Na等含量都明显高于百合干,而百合干中Mg的含量较高。实验结果还表明用LIBS技术检测、对比冻干植物样品中微量元素含量是一种快速、有效的分析方法。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

激光诱导击穿光谱(LIBS)在植物样品上面的应用是一个较新的课题.为将LIBS技术能实际应用于与食品安全相关的领域,实验中对三种真空冻干水果样品进行了初步LIBS实验研究,鉴别了其LIBS光谱,并选取典型光谱线,运用统计学方法分析比较了三种水果中Ca,Na,K,Fe,Al,Mg六种元素含量的差别.实验结果表明,苹果中Na的含量最高,Ca的含量最低,三种水果样品中的K,Fe,Mg等元素含量也都有差异.实验结果还表明LIBS技术是一种检测、对比植物样品中微量元素含量的有效手段.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A LIBS setup was built in the Institute of Modern Physics. In our experiments, LIBS spectra produced by infrared radiation of Nd : YAG nanosecond laser with 100 and 150 mJ pulse energy, respectively, were measured by fiber optic spectrometer in the ranges of 230-430 run and 430-1080 nm with a delay time of 1.7 and gate width of 2 ms for potato and lily samples prepared by vacuum freeze-dried technique. The lines from different metal elements such as K, Ca, Na, Mg, Fe, Al, Mn and Ti, and nonmetal elements such as C, N, O and H, and some molecular spectra from C-2, CaO, and CN were identified according to their wavelengths. The relative content of the six microelements, Ca, Na, K, Fe, Al, and Mg in the samples were analyzed according to their representative line intensities. By comparison we found that there are higher relative content of Ca and Na in lily samples and higher relative content of Mg in potato samples. The experimental results showed that LIBS technique is a fast and effective means for measuring and comparing the contents of microelements in plant samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

激光诱导击穿光谱(LIBS)在植物样品上面的应用是一个较新的课题. 为将LIBS技术能实际应用于与食品安全相关的领域,实验中对三种真空冻干水果样品进行了初步LIBS实验研究,鉴别了其LIBS光谱,并选取典型光谱线,运用统计学方法分析比较了三种水果中Ca,Na,K,Fe,Al,Mg六种元素含量的差别. 实验结果表明,苹果中Na的含量最高,Ca的含量最低,三种水果样品中的K,Fe,Mg等元素含量也都有差异. 实验结果还表明LIBS技术是一种检测、对比植物样品中微量元素含量的有效手段.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laser-induced breakdown plasma is produced by using Q-switched Nd: YAG laser operating at 532 nm, which interacts with the Al alloy sample target in air. The spectral lines in the 230-440 nm wavelength range have been identified, and based on the calibration-free method, the mass concentration of Al alloy are obtained, which is in good agreement with the standard value of the sample.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the capabilities of laser-induced break down spectroscopy (LIBS) for rapid analysis to multi-component plant are illustrated using a 1064 nm laser focused onto the surface of folium lycii. Based on homogeneous plasma assumption, nine of essential micronutrients in folium lycii are identified. Using Saha equation and Boltzmann plot method electron density and plasma temperature are obtained, and the irrelative concentration (Ca, Mg, Al, Si, Ti, Na, K, Li, and Sr) are obtained employing a semi-quantitative method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laser-induced breakdown spectroscopy (LIBS) as a powerful analytical technique is applied to analyze trace-elements in fresh plant samples. We investigate the LIBS spectra of fresh holly leaves and observe more than 430 lines emitted from 25 elements and molecules in the region 230-438 nm. The influence of laser wavelength on LIBS applied to semi-quantitative analysis of trace-element contents in plant samples is studied. The results show that the UV laser has lower relative standard deviations and better repeatability for semi-quantitative analysis of trace-element contents in plant samples. This work may be helpful for improving the quantitative analysis power of LIBS applied to plant samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文利用Nd:YAG纳秒激光器与配有CCD探测器的四通道光纤光谱仪建立了一套可用于植物样品激光诱导击穿光谱(LIBS)测量的实验装置。基于该实验装置,论文着重开展了激光参数、探测角度、延迟时间等对LIBS 光谱影响以及植物样品LIBS光谱定性、定量分析两方面的实验研究工作。通过实验研究发现:1、在某一激光能量点处,LIBS有最大的相对光谱强度;2、红外(IR)激光击穿阈值要高于紫外(UV)激光,并且IR激光产生的LIBS光谱中连续谱强度也强于UV激光;3、粒子谱线信噪比随时间演化的方式与其产生机制有密切关系;4、光纤与样品表面法线方向夹角越小越容易获得信噪比大的光谱。对所获得的植物样品LIBS光谱分析得到以下结论:1、在230~1080nm范围内,从苹果表皮样品的LIBS中观测到了380余条谱线,鉴别分析出二十多种元素和分子;2、对经过真空冻干处理的三种水果和两种蔬菜样品中的K、Ca、Fe、Na、Mg、Al六种微量元素相对含量分别进行了比较。实验结果表明LIBS技术是分析比较植物样品中微量元素含量的一种有效方法

Relevância:

10.00% 10.00%

Publicador:

Resumo:

激光诱导击穿光谱技术(LIBS)具有无需样品制备,原位快速分析,可进行实时控制的特点使其在钢铁冶炼控制中具有巨大的实际应用价值。本文以波长为1 064 nm的Nd∶YAG调Q固体激光器为激发光源,CCD为探测器,高合金钢GBW01605—01609系列为样品,在建立的LIBS实验装置上研究激光与合金钢之间的相互作用。系统地研究了观测距离、激光能量对高合金钢样品中激光诱导击穿谱特性的影响,并分析了LIBS信号的时间分辨特性,确定了将LIBS用于合金钢微量元素定量分析时的最佳实验条件。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

利用激光诱导击穿光谱定量分析了铝合金中多种元素的成分。采用Nd∶YAG脉冲激光器,在空气环境下烧蚀铝合金固体样品获得等离子体。利用多通道光栅光谱仪和CCD检测器对200~980nm波长范围的光谱进行同时检测。研究了检测时延、激光脉冲能量、元素深度分布对光谱强度的影响,考虑这些因素之后对实验参数进行了优化。在优化的实验参数下对国家标准铝合金样品中的八种元素Si,Fe,Cu,Mn,Mg,Zn,Sn及Ni进行了定标,并利用定标曲线对一种铝合金样品进行了定量分析。实验结果表明,测量结果的相对标准偏差(RSD)最大为5.89%,相对误差在-20.99%~15%范围内,说明对铝合金样品成分进行定量分析,激光诱导击穿光谱是一种有效的光谱分析工具,但是分析结果的准确度仍需要提高。