51 resultados para Inventory System and its Motivation ,
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Digital Speckle Correlation Method (DSCM) is a useful tool for whole field deformation measurement, and has been applied to analyze the deformation field of rock materials in recent years. In this paper, a Geo-DSCM system is designed and used to analyse the more complicated problems of rock mechanics, such as damage evolution and failure procedure. A weighted correlation equation is proposed to improve the accuracy of displacement measurement on a heterogeneous deformation field. In addition, a data acquisition system is described that can synchronize with the test machine and can capture speckle image at various speeds during experiment. For verification of the Geo-DSCM system, the failure procedure of a borehole rock structure is inspected and the evolution of the deformation localization is analysed. It is shown that the deformation localization generally initializes at the vulnerable area of the rock structure but may develop in a very complicated way.
Resumo:
This paper proposes a novel and innovative scheme for 10Gb/s parallel Very Short Reach (VSR) optical communication system. The optimized scheme properly manages the SDH/SONET redundant bytes and adjusts the position of error detecting bytes and error correction bytes. Compared with the OIF-VSR4-01.0 proposal, the scheme has a coding process module. The SDH/SONET frames in transmission direction are disposed as follows: (1) The Framer-Serdes Interface (FSI) gets 16x622.08Mb/s STM-64 frame. (2) The STM-64 frame is byte-wise stripped across 12 channels, all channels are data channels. During this process, the parity bytes and CRC bytes are generated in the similar way as OIF-VSR4-01.0 and stored in the code process module. (3) The code process module will regularly convey the additional parity bytes and CRC bytes to all 12 data channels. (4) After the 8B/10B coding, the 12 channels is transmitted to the parallel VCSEL array. The receive process approximately in reverse order of transmission process. By applying this scheme to 10Gb/s VSR system, the frame size in VSR system is reduced from 15552x12 bytes to 14040x12 bytes, the system redundancy is reduced obviously.
Resumo:
This paper introduced a long-term ambulatory intragastric pH monitoring system, which is designed for prolonged ambulatory studies of Gastroesophageal Reflux Diseases. The whole system is composed of the gastric catheter with two pH sensors, a small data logger (Microdatalog), and a notebook PC. In this paper, the design of monitoring system hardware and software are described in detail. Clinical applications reveal good results.
Resumo:
In the study, a novel microemulsion system, consisting of water, iso-propanol and n-butanol, was developed to synthesize the nanostructured La0.95Ba0.05MnAl11O19 catalyst with high surface area and catalytic activity for methane combustion.
Resumo:
(A) novel chemiluminescence (CL) system was evaluated for the determination of hydrogen peroxide, glucose and ascorbic acid based on hydrogen peroxide, which has a catalytic-cooxidative effect on the oxidation of luminol by KIO4. Hydrogen peroxide can be directly determined by luminol-KIO4 -H2O2 CL system. The detection limit was 3.0 x 10(-8) mol l(-1) and the calibration graph was linear over the range of 2.0 x 10(-7)-6.0 x 10(-4) mol l(-1). The relative standard deviation of H2O2 was 1.1% for 2.0 x 10(-6) mol l(-1) (N = 11). Glucose was indirectly determined through measuring the H2O2 generated by the oxidation of glucose in the presence of glucose oxidase at pH 7.6. The present method provides a source for H2O2, which, in turn, coupled with the luminol-KIO4-H2O2 CL reaction system. The CL was linearly correlated with glucose concentration of 0.6-110 mu g ml(-1). The relative standard deviation was 2.1% for 10 mu g ml(-1) (N = 11). Detection limit of glucose was 0.08 mu g ml(-1). Ascorbic acid was also indirectly determined by the suppression of luminol-KIO4-H2O2 CL system. The calibration curve was linear over the range of 1.0 x 10(-7)-1.0 x 10(-5) mol l(-1) of ascorbic acid. The relative standard deviation was 1.0% for 8.0 x 10(-7) mol l(-1) (N = 11). Detection limit of ascorbic acid was 6.0 x 10(=8) mol l(-1). These proposed methods have been applied to determine glucose, ascorbic acid in tablets and injection. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
A nerve growth factor (NGF) was isolated from the venom of Chinese cobra (Naja naja ntr a) by ion exchange chromatography, gel filtration and fast protein liquid chromatography (FPLC). The N-terminal sequence of 22 amino acid residues was identical with other NGFs previously purified from the venom of the same genus. The NGF monomer molecular weight was estimated to be 13 500 by reducing SDS-PAGE and the isoelectric point was determined to be 7.2 by isoelectric focusing electrophoresis. NGF improved the epididymal sperm motility of male rats and increased the pregnancy rate and fetus number of mated female rats. The serum levels of luteinizing hormone (LH) and follicle stimulating hormone (FSH) of male rats administrated NGF + gossypol was lower than that of male rats administrated gossypol. Histological sections of testes and epididymides showed that NGF reduced the destructive effects of gossypol on rat testes. (C) 1999 Elsevier Science Inc. All rights reserved.
Resumo:
The electrooxidation polymerization of phenothiazine derivatives, including azure A and toluidine blue 0, has been studied at screen-printed carbon electrodes in neutral phosphate buffer. Both compounds yield strongly adsorbed electroactive polymer with reversible behavior and formal potentials closed to 0.04 V at pH 6.9. The modified electrodes exhibited good stability and electrocatalysis for NADH oxidation in phosphate buffer (pH 6.9), with an overpotential of more than 500 mV lower than that of the bare electrodes. Further, the modified screen-printed carbon electrodes were found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 0.5-100 muM.
Resumo:
The electrooxidation polymerization of azure B on screen-printed carbon electrodes in neutral phosphate buffer was studied. The poly(azure B) modified electrodes exhibited excellent electrocatalysis and stability for dihydronicotinamide adenine dinucleotide (NADH) oxidation in phosphate buffer (pH 6.9), with an overpotential of more than 400 mV lower than that at the bare electrodes. Different techniques, including cyclic voltammetry, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy have been employed to characterize the poly (azure B) film. Furthermore, the modified screen-printed carbon electrodes were found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 0.5 muM to 100 muM.
Resumo:
A poly(thionine) modified screen-printed carbon electrode has been prepared by an electrooxidative polymerization of thionine in neutral phosphate buffer. The modified electrodes are found to give stable and reproducible electrocatlytic responses to NADH and exhibit good stability. Several techniques, including cyclic voltammetry, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM), have been employed to characterize the poly(thionine) film. Further, the modified screen-printed carbon electrode was found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 5-100 muM.
Resumo:
Emission of europium(II) and europium(III) have been observed in SrMgF4 xEu, yTb phosphors winch are synthesized in Ar flow. The valence state of En is influenced by terbium, It is noted that the intensities of the ESR peaks corresponding to Eu2+ are increased when terbium ion is codopech this can be explained by electron transfer mechanism which is Eu3++Tb3+-->Eu2++Tb4+. And its equilibrium constant is calculated.
Resumo:
Nonstoichiometric series SmF(x) (2.0 less-than-or-equal-to x less-than-or-equal-to 3.0) have been synthesized by reduction of samarium trifluoride with hydrogen for several times, and the stoichiometric samarium difluoride has been obtained. The structure of nonstoichiometric samarium fluoride series and the valency of samarium ion are briefly discussed. The valent change process of samarium ion at high temperatures in different atmospheres is investigated.