在传统哈特曼检验法基础上研制成功一种扫描型哈特曼检测新装置。可对最大口径为Ф300mm的聚焦镜在全口径范围内进行采样测量。该检测装置由大口径标准平行光管、扫描式哈特曼光阑、被俭聚焦镜、CCD摄像机及计算机组成。在水平和垂直两个径向上开有等间距排列且相互错开半个间距的小孔。并且在步进电机的驱动下绕光轴旋转。可对被检聚焦镜进行全口径连续采样。对有效口径为夺154mm的斐索平面干涉仪非球面准直物镜的球差及焦斑能量集中度进行了测量。进而由球差计算得到了波像差。并用干涉法对该准直物镜进行了测量。球差的理论值与测量值

Relevância:

60.00% 60.00%

Publicador:

Resumo:

提出了一种利用扫描型哈特曼检测装置检验靶镜光学质量的技术.该装置对传统哈特曼检验装置的光阑进行了改进,通过扫描型哈特曼光阑的旋转扫描,可对被检靶镜全口径范围内连续采样.利用该扫描型哈特曼检测装置对一块口径为φ270 mm的非球面靶镜的能量集中度和波像差进行了检验,其结果与激光数字波面干涉仪的测量结果相吻合,其中能量集中度的相对测量误差为7.7%,波像差的相对测量误差为10.2%,验证了该检测技术的有效性.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A relative displacement between the grid points of optical fields and those of phase screens may occur in the simulation of light propagation through the turbulent atmosphere. A statistical interpolator is proposed to solve this problem in this paper. It is evaluated by the phase structure function and numerical experiments of light propagation through atmospheric turbulence with/without adaptive optics (AO) and it is also compared with the well-known linear interpolator under the same condition. Results of the phase structure function show that the statistical interpolator is more accurate in comparison with the linear one, especially in the high frequency region. More importantly, the long-exposure results of light propagation through the turbulent atmosphere with/without AO also show that the statistical interpolator is more accurate and reliable than the linear one. (C) 2009 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

本文给出含气泡液态金属的磁流体力学基本方程,以及Hartmann流动的解。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The encircled energy of a focusing lens is one of the parameters directly affecting the target efficiency in high-power laser facilities. The direct measurement method of the encircled energy for the focusing lens based on the scanning Hartmann test is proposed in this paper. With the scanning Hartmann test setup, the information in the whole aperture of the focusing lens can be achieved. The encircled energy can be obtained by analyzing the spot diagram on the focal plane of the focusing lens. In experiments, the encircled energy of an aspheric focusing lens is measured using this method. The measurement result is in good agreement with that derived from measurement data by an interferometer and the difference is 7.7%. (C) 2006 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A systemic study was initiated to identify stage-specific expression genes in fish embryogenesis by using suppression subtractive hybridization (SSH) technique. In this study, we presented a preliminary result on screen for stage-specific expression genes between tail bud stage (TBS) and heartbeat beginning stage (HBS) in gynogenetic silver crucian carp (Carassius auratus gibelio). Two SSH plasmid libraries specific for TBS embryos and HBS embryos were constructed, and stage-specific expression genes were screened between the two stages. 1963 TBS positive clones and 2466 HBS positive clones were sampled to PCR amplification, and 1373 TBS and 1809 HBS PCR positive clones were selected to carry out dot blots. 169 TBS dot blot positive clones and 272 HBS dot blot positive clones were sequenced. Searching GenBank by using these nucleotide sequences indicated that most of the TBS dot blot positive clones could not be found homologous sequences in the database, while known genes were mainly detected from HBS dot blot positive clones. Of the 79 known genes, 20 were enzymes or kinases involved in important metabolism of embryonic development. Moreover, specific expressions of partial genes were further confirmed by virtual northern blots. This study is the first step for making a large attempt to study temporal and spatial control of gene expression in the gynogenetic fish embryogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Layer-by-layer electrodeposition of redox polymer/enzyme composition films on screen-printed carbon electrodes for fabrication of reagentless enzyme biosensors has been proposed and the resulting films were found to be very stable and rigid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrooxidation polymerization of phenothiazine derivatives, including azure A and toluidine blue 0, has been studied at screen-printed carbon electrodes in neutral phosphate buffer. Both compounds yield strongly adsorbed electroactive polymer with reversible behavior and formal potentials closed to 0.04 V at pH 6.9. The modified electrodes exhibited good stability and electrocatalysis for NADH oxidation in phosphate buffer (pH 6.9), with an overpotential of more than 500 mV lower than that of the bare electrodes. Further, the modified screen-printed carbon electrodes were found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 0.5-100 muM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrooxidation of thionine on screen-printed carbon electrode gives rise to the modification of the surface with amino groups for the covalent immobilization of enzymes such as horseradish peroxidase (HRP). The biosensor was constructed using multilayer enzymes which covalently immobilized onto the surface of amino groups modified screen-printed carbon electrode using glutaraldehyde as a bifunctional reagent. The multilayer assemble of HRP has been characterized with the cyclic voltammetry and the faradaic impedance spectroscopy. The H2O2 biosensor exhibited a fast response (2 s) and low detection limit (0.5 muM).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrooxidation polymerization of azure B on screen-printed carbon electrodes in neutral phosphate buffer was studied. The poly(azure B) modified electrodes exhibited excellent electrocatalysis and stability for dihydronicotinamide adenine dinucleotide (NADH) oxidation in phosphate buffer (pH 6.9), with an overpotential of more than 400 mV lower than that at the bare electrodes. Different techniques, including cyclic voltammetry, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy have been employed to characterize the poly (azure B) film. Furthermore, the modified screen-printed carbon electrodes were found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 0.5 muM to 100 muM.