13 resultados para Foot Measurement Evaluation
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
The forward scattering light (FSL) received by the detector can cause uncertainties in turbidity measurement of the coagulation rate of colloidal dispersion, and this effect becomes more significant for large particles. In this study, the effect of FSL is investigated on the basis of calculations using the T-matrix method, an exact technique for the computation of nonspherical scattering. The theoretical formulation and relevant numerical implementation for predicting the contribution of FSL in the turbidity measurement is presented. To quantitatively estimate the degree of the influence of FSL, an influence ratio comparing the contribution of FSL to the pure transmitted light in the turbidity measurement is introduced. The influence ratios evaluated under various parametric conditions and the relevant analyses provide a guideline for properly choosing particle size, measuring wavelength to minimize the effect of FSL in turbidity measurement of coagulation rate.
Resumo:
An electrochemical technique for the real-time detection of hydrogen peroxide (H2O2) was employed to describe respiratory burst activity (RBA) of phagocytes in plasma which can be used to evaluate the ability of immune system and disease resistance. The method is based upon the electric current changes, by redox reaction on platinum electrode of extracellular hydrogen peroxide (H2O2) released from phagocytes stimulated by the zymosan at 680 mV direct current (d.c.). Compared with the control, activation of respiratory burst by zymosan particles results in a high amperometric response, and a current peak was obtained during the whole monitoring process. The peak current was proved by addition Of Cu2+ and other controls, to be the result of intense release of H2O2 from phagocytes. The peak area was calculated and used to evaluate the quantity of effective H2O2, which represents the quantity of H2O2 beyond the clearance of related enzymes in plasma. According to Faraday's law, the phagocytes' ability of prawns to generate effective H2O2 was evaluated from 1.253 x 10(-14) mol/cell to 6.146 x 10(-14) mol/cell, and carp from 1.689 x 10(-15) Mol/Cell to 7.873 x 10(-1)5 mol/cell. This method is an acute and quick detection of extracellular effective H2O2 in plasma and reflects the capacity of phagocytes under natural conditions, which could be applied for selecting species and parents with high immunity for breeding in aquaculture. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The effectiveness of Oliver & Pharr's (O&P's) method, Cheng & Cheng's (C&C's) method, and a new method developed by our group for estimating Young's modulus and hardness based on instrumented indentation was evaluated for the case of yield stress to reduced Young's modulus ratio (sigma(y)/E-r) >= 4.55 x 10(-4) and hardening coefficient (n) <= 0.45. Dimensional theorem and finite element simulations were applied to produce reference results for this purpose. Both O&P's and C&C's methods overestimated the Young's modulus under some conditions, whereas the error can be controlled within +/- 16% if the formulation was modified with appropriate correction functions. Similar modification was not introduced to our method for determining Young's modulus, while the maximum error of results was around +/- 13%. The errors of hardness values obtained from all the three methods could be even larger and were irreducible with any correction scheme. It is therefore suggested that when hardness values of different materials are concerned, relative comparison of the data obtained from a single standard measurement technique would be more practically useful. It is noted that the ranges of error derived from the analysis could be different if different ranges of material parameters sigma(y)/E-r and n are considered.
Resumo:
This paper describes the generation of pulsed, high-speed liquid jets using the cumulation method. This work mainly includes (1) the design of the nozzle assembly, (2) the measurement of the jet velocity and (3) flow visualization of the injection sequences. The cumulation method can be briefly described as the liquid being accelerated first by the impact of a moving projectile and then further after it enters a converging section. The experimental results show that the cumulation method is useful in obtaining a liquid jet with high velocity. The flow visualization shows the roles of the Rayleigh-Taylor and Kelvin-Helmholtz instabilities in the breakup of the liquid depend on the jet diameter and the downstream distance. When the liquid jet front is far downstream from the nozzle exit, the jet is decelerated by air drag. Meanwhile, large coherent vortex structures are formed surrounding the jet. The liquid will break up totally by the action of these vortices. Experimental results showing the effect of the liquid volume on the jet velocity are also included in this paper. Finally, a method for measuring the jet velocity by cutting two carbon rods is examined.
Resumo:
The existing theories dealing with the evaluation of the absolute coagulation rate constant by turbidity measurement were experimentally tested for different particle-sized (radius = a) suspensions at incident wavelengths (lambda) ranging from near-infrared to ultraviolet light. When the size parameter alpha = 2 pi a/lambda > 3, the rate constant data from previous theories for fixed-sized particles show significant inconsistencies at different light wavelengths. We attribute this problem to the imperfection of these theories in describing the light scattering from doublets through their evaluation of the extinction cross section. The evaluations of the rate constants by all previous theories become untenable as the size parameter increases and therefore hampers the applicable range of the turbidity measurement. By using the T-matrix method, we present a robust solution for evaluating the extinction cross section of doublets formed in the aggregation. Our experiments show that this new approach is effective in extending the applicability range of the turbidity methodology and increasing measurement accuracy.
Resumo:
The extinction cross sections of a system containing two particles are calculated by the T-matrix method, and the results are compared with those of two single particles with single-scattering approximation. The necessity of the correction of the refractive indices of water and polystyrene for different incident wavelengths is particularly addressed in the calculation. By this means, the volume fractions allowed for certain accuracy requirements of single-scattering approximation in the light scattering experiment can be evaluated. The volume fractions calculated with corrected refractive indices are compared with those obtained with fixed refractive indices which have been rather commonly used, showing that fixed refractive indices may cause significant error in evaluating multiple scattering effect. The results also give a simple criterion for selecting the incident wavelength and particle size to avoid the 'blind zone' in the turbidity measurement, where the turbidity change is insensitive to aggregation of two particles.
Resumo:
A Talbot scanning near-field optical microscopy (SNOM) method for non-contact evaluating of high-density gratings was described. This method combines the Talbot self-imaging effect of the gratings and the conventional SNOM technique without damage. The significant advantages of this method are its simple structure, reliable and fast measurement for the surface quality of the tested gratings. Experimental results of three different kinds of gratings were demonstrated to indicate that this method is effective for evaluation surface quality of high-density gratings. (c) 2004 Elsevier B.V. All rights reserved.
Resumo:
We demonstrate a technique based on wet chemical etching that enables quick and accurate evaluation of edge- and screw/mixed-type threading dislocations (TDs) in GaN. Large and small etch pits are formed by phosphoric acid on the etched surfaces. The large etch pits are attributed to screw/mixed TDs and the small ones to edge TDs, according to their locations on the surface and Burgers vectors of TDs. Additionally, the origin of small etch pits is confirmed by a transmission electron microscopy. The difference in the size of etch pits is discussed in view of their origin and merging. Overetching at elevated temperatures or for a long time may result in merging of individual etch pits and underestimating of the density of TDs. Wet chemical etching has also been proved efficient in revealing the distribution of TDs in epitaxial lateral overgrowth GaN.
Resumo:
The measurements of one hundred 1.3 mu m planar buried crescent (PBC) structure InGaAsP/InP lasers demonstrate that parameters given by the electrical derivative of varied temperature and the variation of the parameters with temperature can be used to appraise the quality and reliability of semiconductor lasers effectual. By measurement of electrical derivative curves one can evaluate the quality of epitaxial wafer and chip, find the problems in the material and the technology, offer the useful information on increasing the quality and improving the technology of devices. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
The composition and stain distributions in the InGaN epitaxial films are jointly measured by employing various x-ray diffraction (XRD) techniques, including out-of-plane XRD at special planes, in-plane grazing incidence XRD, and reciprocal space mapping (RSM). It is confirmed that the measurement of (204) reflection allows a rapid access to estimate the composition without considering the influence of biaxial strain. The two-dimensional RSM checks composition and degree of strain relaxation jointly, revealing an inhomogeneous strain distribution profile along the growth direction. As the film thickness increases from 100 nm to 450 nm, the strain status of InGaN films gradually transfers from almost fully strained to fully relaxed state and then more in atoms incorporate into the film, while the near-interface region of InGaN films remains pseudomorphic to GaN.
Resumo:
Heart disease is one of the main factor causing death in the developed countries. Over several decades, variety of electronic and computer technology have been developed to assist clinical practices for cardiac performance monitoring and heart disease diagnosis. Among these methods, Ballistocardiography (BCG) has an interesting feature that no electrodes are needed to be attached to the body during the measurement. Thus, it is provides a potential application to asses the patients heart condition in the home. In this paper, a comparison is made for two neural networks based BCG signal classification models. One system uses a principal component analysis (PCA) method, and the other a discrete wavelet transform, to reduce the input dimensionality. It is indicated that the combined wavelet transform and neural network has a more reliable performance than the combined PCA and neural network system. Moreover, the wavelet transform requires no prior knowledge of the statistical distribution of data samples and the computation complexity and training time are reduced.
Resumo:
Modeling of the gel-immobilized cell system requires accurate measurement of diffusion coefficients. Three methods of the quasi-steady-state (QSS) method, the time-lag (TL) method and a variant quasi-steady-state (VQSS) method were critically assessed and compared for the evaluation of diffusivities using the diffusion cell technique. Experimental data from our laboratory were used for the analysis of the influence of crucial theoretical assumptions not being fulfilled in each method. The results highlighted a risk in obtaining highly variable diffusion coefficients by not validating the QSS and the accuracy of the measurements. In the TL method, the estimation of diffusivities based on the plot intercept that was mostly used in the literature, results in a many fold lower value when compared to that based on the plot slope. The comparison with the QSS and VQSS methods confirmed similar diffusivity obtained by the TL method based on the plot slope. It thus suggested that the correct estimation of diffusivities by the TL method could be based on the plot slope only. Furthermore, the errors associated with the solute mass in the gel, the sample withdrawal and the non-negligible concentration changes in the chambers were also discussed. It is concluded that diffusion cell technique has to be employed cautiously for a correct evaluation of diffusivities. (C) 2001 Elsevier Science B.V. All rights reserved.