10 resultados para Farm Credit System (U.S.)
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Abstract A state-of-the-art high energy heavy ion microbeam irradiation system is constructed at the Institute of Modern Physics of the Chinese Academy of Sciences. This microbeam system operates in both full current intensity mode and single ion mode. It delivers a predefined number of ions to preselected targets for research in biology and material science. The characteristic of this microbeam system is high energy and vertical irradiation. A quadrupole focusing system, in combination with a series of slits, has been designed to optimize the spatial resolution. A symmetrically achromatic system leads the beam downwards and serves simultaneously as an energy analyzer. A high gradient quadrupole triplet finally focuses a C6+ ion beam to 1 µm in the vacuum chamber within the energy range from 10 MeV/u to 100 MeV/u. In this paper, the IMP microbeam system is described in detail. A systematic investigation of the ion beam optics of this microbeam system is presented together with the associated aberrations. Comparison is made between the IMP microbeam system and the other existing systems to further discuss the performance of this microbeam. Then the optimized initial beam parameters are given for high resolution and high hitting efficiency. At last, the experiment platform is briefly introduced.
Resumo:
报道了一种基于荧光猝灭原理的光纤氧气传感器.采用塑料光纤作为传感和传光元件进行氧气传感,传感头制成U形.以邻菲咯啉钌作为荧光标记物,用溶胶-凝胶法制备敏感材料.采用相移法来实现对荧光寿命的测定.测量了不同弯曲半径传感头对氧气传感的灵敏度,发现当U形光纤的弯曲半径较小时系统的灵敏度较高.对荧光寿命和氧气浓度的关系进行了测量,发现二者呈亚线性关系,提出双荧光体模型解释这一实验现象.
Resumo:
本文提出了一种基于U型塑料光纤和邻啡咯啉钌的溶解氧传感器。光纤传感头放在样品池中,测量了不同氮氧体积比情况下荧光强度和寿命。研究了邻啡咯啉钌的浓度、传感头的退火时间和U型光纤的弯曲半径对系统灵敏度的影响。我们提出了双层模型来解释实验结果不符合S-V方程的实验现象,并用双层模型分析了弯曲半径对系统灵敏度的影响。通过对溶解氧浓度和荧光寿命亚线性曲线的拟合,我们得出敏感层的厚度和S-V系数分别为0.59和0.61。
Resumo:
For an orthotropic laminate, an equivalent system with doubly cyclic periodicity is introduced. Then a 3-dimensional finite element model for the equivalent system is transformed into the unitary space, where the large finite element matrix equation is decoupled into some small matrix equations. Such a decoupling very efficiently reduces the computational effort. For an orthotropic laminate with four clamped edges, no exact elasticity solution is available, and the deflection values predicted by different methods have a considerable difference each other for a small length-to-thickness ratio. The present predictions are the largest because the present method is a full 3-dimensional finite element analysis without superfluous constraints. Illustrative numerical examples are presented to observe the distributions of stresses through the thickness of the laminates. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Within the framework of the dinuclear system (DNS) model, production cross sections of new superheavy nuclei with charged numbers Z=108-114 are analyzed systematically. Possible combinations based on the actinide nuclides U-238, Pu-244, and Cm-248,Cm-250 with the optimal excitation energies and evaporation channels are pointed out to synthesize new isotopes that lie between the nuclides produced in the cold fusion reactions and the Ca-48-induced fusion reactions experimentally, which are feasible to be constructed experimentally. It is found that the production cross sections of superheavy nuclei decrease drastically with the charged numbers of compound nuclei. Larger mass asymmetries of the entrance channels enhance the cross sections in 2n-5n channels.
Resumo:
The micro-beam irradiation system, which focuses the beam down to micron order and precisely delivers a predefined number of ions to a predefined spot of micron order, is a powerful tool for radio-biology, radio-biomedicine and micromachining. The Institute of Modern Physics of Chinese Academy of Sciences is developing a heavy-ion microbeam irradiation system up to intermediate energy. Based on the intermediate and low energy beam provided by Heavy Ion Research Facility of Lanzhou, the micro-beam system takes the form of the magnetic focusing. The heavy-ion beam is conducted to the basement by a symmetrical achromatic system consisting of two vertical bending magnets and a quadrupole in between. Then a beam spot of micron order is formed by a magnetic triplet quadrupole of very high gradient. The sample can be irradiated either in vacuum or in the air. This system will be the first opening platform capable of providing heavy ion micro-beam, ranging from low (10MeV/u) to intermediate energy (100MeV/u), for irradiation experiment with positioning and counting accuracy. Target material may be biology cell, tissue or other non-biological materials. It will be a help for unveiling the essence of heavy-ion interaction with matter and also a new means for exploring the application of heavy-ion irradiation.
Resumo:
The reduced velocity correlation functions of the Intermediate Mass Fragments (IMFs) were measured in the reactions of Ar-36+ Sn-112,Sn-124 at 35MeV/u. The anti-correlation at small reduced velocities is more pronounced in Ar-36+ Sn-124 system than that in Ar-36+ Sn-112 system. The difference of the correlation functions between the two reactions is mainly contributed by the particle pairs with high momenta. A three-body Coulomb repulsive trajectory code (MENEKA) is employed to calculate the emission time scale of IMFs for-the both systems. The time scale is 150fm/c in the Ar-36+ Sn-112 system and 120fm/c in the Ar-36+ Sn-124 system, respectively. A calculation based on an Isospin dependence Quantum Molecular Dynamics code (IQMD) reveals that the emission time spectrum of IMFs is shifted slightly leftwards in Ar-36+ Sn-124 compared with that in the Ar-16+ Sn-112 system, indicating a shorter emission time scale. Correspondingly, the central density of the hot nuclei decreases faster in Ar-36+ Sn-124 than in Ar-36+ Sn-112
Resumo:
In the concept of dinuclear system, the quasifission rate from Kramers formula has been incorporated in the master equation in order to study the competition between fusion and qusifission. Mass yields of quasifission products of the three reactions Ca-48 + Pu-244, Ca-48 + U-238 and Fe-58 + Th-232 have been calculated, and the experimental data are reproduced very well, which is a critical test for the existing fusion model. Also we have shown the time evolution of the mass distributions of quasifission products, which provides valuable information of the process of competition between fusion and quasifission.