8 resultados para Education, Secondary - Computer-assisted instruction - Australia
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
A software has been developed for the peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) after high resolution gas chromatography coupled with mass spectrometry (HRGC/HRMS). Based on the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retention times of all PCDD and PCDF can be calibrated automatically and accurately. Therefore, it is very convenient to identify the peaks by comparing the retention of samples and the calibrated retention times of their chromatograms. Hence, this approach is very significant because it is impossible to obtain always a standard chromatogram and PCDD/F analysis are very expensive and time consuming. The calibration results can be transferred to Excel for calculation. The approach is a first step to store costly and environmentally relevant data for future application.
Resumo:
In the present study, the quality of post-thaw sperm of red seabream Pagrus major frozen with 6-24% DMSO was investigated. The motility, average path velocity and fertilizing capacity of fresh and their corresponding post-thaw sperm were examined for evaluation of the post-thaw sperm motion characteristics and its association with fertilizing capacity. An analysis of sperm motility before and after cryopreservation has been performed using computer-assisted sperm analysis (CASA). For post-thaw sperm frozen with 12-21% DMSO, the percentages of motile sperm were not significantly (P > 0.05) changed 10 s after activation. Moreover, the main motility pattern and swimming velocity of the motile post-thaw sperm were not significantly (P > 0.05) changed and the progressive linear motion was still the dominant pattern. However, the total motility of post-thaw sperm (72.3 +/- 6.3%) 30 s after activation was (P < 0.05) lower than the corresponding fresh sperm (82.7 +/- 7.2%). Additionally, the fertilizing capacity of post-thaw sperm was investigated with a standardized sperm to egg ratio 500:1. There is a linear regression relationship between the percentage of motile post-thaw sperm and fertilizing capability. These data demonstrate that 12-21% DMSO can provide good protection to the sperm during the freezing-thawing process. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
A data manipulation method has been developed for automatic peak recognition and result evaluation in the analysis of organic chlorinated hydrocarbons with dual-column gas chromatography. Based on the retention times of two internal standards, pentachlorotoluene and decachlorobiphenyl, the retention times of chlorinated hydrocarbons can be calibrated automatically and accurately. It is very convenient to identify the peaks by comparing the retention times of samples with the calibrated retention times calculated from the relative retention indices of standards. Meanwhile, with a suggested two-step evaluation method the evaluation coefficients and the suitable quantitative results of each component can be automatically achieved for practical samples in an analytical system using two columns with different polarities and two internal standards. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
利用Fluent软件、ISAT算法与由CARM(Computer Assisted Reduction Method)简化而来的11组分、7步反应的乙烯简化机理对碳氢燃料/空气的超声速燃烧问题进行数值模拟.研究结果表明这种方法是可利用的.计算得到的压力数据与试验压力值可以比较.
Resumo:
Lymphocystis diseases in fish throughout the world have been extensively described. Here we report the complete genome sequence of lymphocystis disease virus isolated in China (LCDV-C), an LCDV isolated from cultured flounder (Paralichthys olivaceus) with lymphocystis disease in China. The LCDV-C genome is 186,250 bp, with a base composition of 27.25% G+C. Computer-assisted analysis revealed 240 potential open reading frames (ORFs) and 176 nonoverlapping putative viral genes, which encode polypeptides ranging from 40 to 1,193 amino acids. The percent coding density is 67%, and the average length of each ORF is 702 bp. A search of the GenBank database using the 176 individual putative genes revealed 103 homologues to the corresponding ORFs of LCDV-1 and 73 potential genes that were not found in LCDV-1 and other iridoviruses. Among the 73 genes, there are 8 genes that contain conserved domains of cellular genes and 65 novel genes that do not show any significant homology with the sequences in public databases. Although a certain extent of similarity between putative gene products of LCDV-C and corresponding proteins of LCDV-1 was revealed, no colinearity was detected when their ORF arrangements and coding strategies were compared to each other, suggesting that a high degree of genetic rearrangements between them has occurred. And a large number of tandem and overlapping repeated sequences were observed in the LCDV-C genome. The deduced amino acid sequence of the major capsid protein (MCP) presents the highest identity to those of LCDV-1 and other iridoviruses among the LCDV-C gene products. Furthermore, a phylogenetic tree was constructed based on the multiple alignments of nine MCP amino acid sequences. Interestingly, LCDV-C and LCDV-1 were clustered together, but their amino acid identity is much less than that in other clusters. The unexpected levels of divergence between their genomes in size, gene organization, and gene product identity suggest that LCDV-C and LCDV-1 shouldn't belong to a same species and that LCDV-C should be considered a species different from LCDV-1.
Resumo:
ICSE
Resumo:
外科手术计算机辅助导航即利用计算机图形图像技术对放射影像学资料进行处理 ,重建二维或三维的医学图像模型 ,同时结合各种空间定位技术 ,在医师的双眼、手术工具及患者的头部之间建立一个实时的环路 ,实现手术过程中器械位置的实时或准实时显示。我们综述了外科手术计算机辅助导航系统的发展历史和研究现状 (重点阐述了其系统结构和关键技术 ,包括空间定位技术、图像处理与显示技术、系统配准技术、头部定位技术等 (最后给出了手术导航系统的发展趋势