186 resultados para Determination method
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Isolation of high neutral lipid-containing microalgae is key to the commercial success of microalgae-based biofuel production. The Nile red fluorescence method has been successfully applied to the determination of lipids in certain microalgae, but has been unsuccessful in many others, particularly those with thick, rigid cell walls that prevent the penetration of the fluorescence dye. The conventional "one sample at a time" method was also time-consuming. In this study, the solvent dimethyl sulfoxide (DMSO) was introduced to microalgal samples as the stain carrier at an elevated temperature. The cellular neutral lipids were determined and quantified using a 96-well plate on a fluorescence spectrophotometer with an excitation wavelength of 530 nm and an emission wavelength of 575 run. An optimized procedure yielded a high correlation coefficient (R-2 = 0.998) with the lipid standard triolein and repeated measurements of replicates. Application of the improved method to several green algal strains gave very reproducible results with relative standard errors of 8.5%, 3.9% and 8.6%, 4.5% for repeatability and reproducibility at two concentration levels (2.0 mu g/mL and 20 mu g/mL), respectively. Moreover, the detection and quantification limits of the improved Nile red staining method were 0.8 mu g/mL and 2.0 mu g/mL for the neutral lipid standard triolein, respectively. The modified method and a conventional gravimetric determination method provided similar results on replicate samples. The 96-well plate-based Nile red method can be used as a high throughput technique for rapid screening of a broader spectrum of naturally-occurring and genetically-modified algal strains and mutants for high neutral lipid/oil production. (C) 2009 Published by Elsevier B.V.
Resumo:
The fast analysis of ranitidine is of clinical importance in understanding its efficiency and a patient's treatment history. In this paper, a novel determination method for ranitidine based on capillary electrophoresis-electrochemiluminescence detection is described. The conditions affecting separation and detection were investigated in detail. End-column detection of ranitidine in 5 mM Ru(bpy)(3)(2+) solution at applied voltage of 1.20 V was performed. Favorable ECL intensity with higher column efficiency was achieved by electrokinetic injection for 10 s at 10 kV. The R.S.D. values of ECL intensity and migration time were 6.38 and 1.84% for 10(-4) M and 6.01 and 0.60% for 10(-5) M, respectively. A detection limit of 7 x 10(-8) M (S/N = 3) was achieved. The proposed method was applied satisfactorily to the determination of ranitidine in urine in 6 min.
Resumo:
A two-dimensional model has been developed based on the experimental results of stainless steel remelting with the laminar plasma technology to investigate the transient thermo-physical characteristics of the melt pool liquids. The influence of the temperature field, temperature gradient, solidification rate and cooling rate on the processing conditions has been investigated numerically. Not only have the appropriate processing conditions been determined according to the calculations, but also they have been predicted with a criterion established based on the concept of equivalent temperature area density (ETAD) that is actually a function of the processing parameters and material properties. The comparison between the resulting conditions shows that the ETAD method can better predict the optimum condition.
Resumo:
A column method was developed to conveniently and reliably determine the soil organic partition coefficients (K-oc) of three insecticides (methiocarb, azinphos-methyl, fenthion), four fungicides (triadimenol, fuberidazole, tebuconazole, pencycuron), and one herbicide (atrazine), in which real soil acted as a stationary phase and the water solution of pesticide as an eluent. The processes of sorption equilibrium were directly shown through a breakthrough curve(BTC). The log K-oc values are 1.69, 1.95, 2.25, 2.55, 2.69, 2.67, 3.10, and 3.33 for atrazine, triadimenol, methiocarb, fuberidazole, azinphos-methyl, tebuconazole, fenthion and pencycuron, respectively.
Resumo:
使用四波混频测试光子晶体光纤的色散和非线性参数
Resumo:
The shear-deformation-potential constant XI-u of the conduction-band minima of Si has been measured by a method which we called deep-level capacitance transient under uniaxial stress. The uniaxial-stress (F) dependence of the electron emission rate e(n) from deep levels to the split conduction-band minima of Si has been analyzed. Theoretical curves are in good agreement with experimental data for the S0 and S+ deep levels in Si. The values of XI-u obtained by the method are 11.1 +/- 0.3 eV at 148.9 K and 11.3 +/- 0.3 eV at 223.6 K. The analysis and the XI-u values obtained are also valuable for symmetry determination of deep electron traps in Si.
Resumo:
A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with fluorescence detection has been developed. 9-(2-Hydroxyethyl)acridone reacts with coupling agent N,N-carbonyldiimidazole at ambient temperature to form activated amide intermediate 9-(2-acridone)oxyethylcarbonylimidazole (AOCD). The amide intermediate (AOCD) preferably reacts with amino compounds under mild reactions in the presence of 4-(dimethylamino)pyridine (base catalyst) in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum lambda(ex) 404 mn and an emission maximum at lambda(em) 440 nm. The labeled derivatives exhibit high stability under reversed-phase conditions. The fluorescence intensities of derivatives in various solvents or at different temperatures were investigated. The method, in conjunction with a gradient elution, offers a baseline resolution of the common amine derivatives on a reversed-phase C-18 column. The LC separation for the derivatized amines shows good reproducibility with acetonitrile-water including 2.5% DMF as mobile phase. The relative standard deviations (n = 6) for each amine derivative are <4.5%. The detection limits (at a signal-to-noise ratio of 3) per injection were 0.16-12.8 ng/mL. Further research for the field of application, based on the AOCD amide intermediate as derivatization reagent, for the determination of free amines in real water samples is achieved.