5 resultados para Concordance

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new approach, short-oligonucleotide-ligation assay on DNA chip (SOLAC), is developed to detect mutations in rifampin-resistant Mycobacterium tuberculosis. The method needs only four common probes to detect 15 mutational variants of the rpoB gene within 12 h. Fifty-five rifampin-resistant M. tuberculosis isolates were analyzed, resulting in 87.3% accuracy and 83.6% concordance relative to DNA sequencing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Based on the theoretical model we have proposed, a complete study on the kinetics of photoincluced anisotropy in diarylethene films is performed. The kinetic curves of molecular concentration, photoincluced dichroism and birefringence are calculated, respectively. It is found that the colored molecular concentration decreases with the increase of the excitation exposure until saturation, and the photoincluced anisotropy increases to a maximum and then decreases gradually. The optimal exposure is 260 J/cm(2). In addition, the transmittance of probe beam reflecting the anisotropy is measured by experiment. The theoretical results are compared with experimental data, and basic concordance is found between both sets of data. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have designed and fabricated the visible vertical-cavity surface-emitting lasers (VCSEL's) by using metalorganic vapor phase epitaxy (MOVPE). We use the 8 lambda optical cavities with 3 quantum wells in AlGaInP/AlGaAs red VCSEL's to reduce the drift leakage current and enhance the model gain in AlGaInP active region. The structure has a p-type stack with 36 DBR pairs on the top and an n-type with 55-1/2 pairs on the bottom. Using micro-area reflectance spectrum, we try to get a better concordance between the center wavelength of DBR and the emitting wavelength of the active region. We used a component graded layer of 0.05 lambda thick (x = 0.5 similar to 0.9) at the p-type DBR AlGaAs/AlAs interface to reduce the resistance of p-type DBR. We use selective oxidation to define the current injection path. Because the oxidation rate of a thick layer is faster than a thinner one, we grown a thick AlAs layer close to the active region. In this way, we got a smaller active region for efficient confinement of injected carriers (the aperture area is 3 x 3 mu m) to reduce the threshold and, at the same time, a bigger conductive area in the DBR layers to reduce the resistance. We employ Zn doping on the p-side of the junction to improve hole injection and control the Zn dopant diffusion to get proper p-i-n junction. At room temperature, pulse operation of the laser has been achieved with the low threshold current of 0.8mA; the wavelength is about 670nm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since physical properties and resistivity of mixed formation fluid change after polymer and water flood reservoir, transformational electric properties of water and polymer flooded zones challenges log interpretation. Conventional log interpretation methods to water flooded reservoirs cannot be employed to water and polymer flooded zones. According to difficulties in water and polymer flooded zones interpretation, we analyzed the variation of electric properties of mixed formation fluid, reservoir parameters and log correspondences, then got further understanding of the applicability of Archie Equations. As the results, we provided reservoir parameter evaluation model in water and polymer flooded zones in this paper. This research shows that micro pore structure, physical parameters and electric correspondence of reservoirs change after being flooded by water and polymer. The resistivity variation of mixed formation fluid depends mainly on affixation conductivity of polymer and salinity of formation water, which is the key to log interpretation and evaluation. Therefore, we summerized the laws of log correspondence in different polymer injection ways, developed electric discrimination model for water and polymer flooded zones, as well as charts to identify flooding conditions with resistivity and sonic logs. Further rock-electric tests and conductive mechanism analysis indicate that the resistivity increasing coefficient(I) and water saturation(Sw) are still in concordance with classical Archie Equations, which can be utilized in quantitative evaluation on water and polymer flooded reservoirs. This sets of methods greatly improved accuracy in water and polymer flooded zone evaluation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study is aimed at examining the degree of the basic scales (validity scales and clinical scales) between The Chinese MMPI and MMPI-2. Four samples (include schizophrenia, affective disorder, neuroses and normal subjects) of 236 subjects completed MMPI/MMPI-2 Combined Questionnaires in groups. The concordance rate for total code types was 90.1%. For 1-point, 2-point, 3-point and elevated code types, they were separately 81.6%, 65.8%, 49.2%, 64%. Only 56.8% of men compared to 73.8% of the women showed concordance in 2-ponit code types between MMPI and MMPI-2. And 58% of normal subjects compared to 48% of the schizophrenia subjects showed concordance in 3-point code types. Of the 236 cases, 156 (66.1%) had code types that were "well-defined" (1-, 2- or 3-point). 1-point, 2-point, 3-point well-defined code types respectively were 38.6%, 29.7%, 21.6%. For 2-point code types which were well-defined, the concordances was 84.3%, 82.8%, 85.7% (all the cases, men, women), higher than 64.4%, 56.8%, 72.9% when they were free-defined. 96.4% of subjects with incongruent 2-point code types had one of the scales in their MMPI code types with MMPI-2 code types. When deference caused by the use of uniform T-scores and new norms in MMPI-2 were found, the differences typically in code types congruence were not very great. Comparison of mean scores for the validity and clinical scales, 7 raw scores and 12 T-scores showed significant difference for MMPI versus MMPI-2 (Form). In spite of significant mean differences, correlational analyses show correlations above 0.92 for the raw scores and T-scores for each gender. All these results showed the good consistence between MMPI and MMPI-2 in basic scales, and showed MMPI-2 should be studied deeply.