28 resultados para Conceptualizing and Measuring
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
The cleavage of adenosine-5'-monophosphate (5'-AMP) and guanosine-5'-monophosphate (S-GMP) by Ce4+ and lanthanide complex of 2-carboxyethylgermanium sesquioxide (Ge-132) in acidic and near neutral conditions was investigated by NMR, HPLC and measuring the liberated inorganic phosphate at 37 degrees C and 50 degrees C, The results showed that 5'-GMP and 5'-AMP was converted to guanine (G), 5'-monophosphate (depurination of 5'-GMP), ribose (depurination and dephosphorylation of 5'-GMP), phosphate and adenine (A), 5'-monophosphate (depurination of 5'-AMP), ribose (depurination and dephosphorylation of 5'-AMP), phosphate respectively by Ce4+. In presence of lanthanide complexes, 5'-GMP and 5'-AMP were converted to guanosine (Guo) and phosphate and adenosine (Ado) and phosphate respectively. The mechanism of cleaving 5'-GMP and 5'-AMP is hydrolytic scission.
Resumo:
It is known that the press formability and the elongation of laser textured sheet are improved, and the service life of textured roll is longer than that of the un-textured roll due to hardening of the treated surface. One of the goals to develop high repetitive rate YAG laser-induced discharge texturing (LIDT) is to get deeper hardening zone. By observing and measuring cross-section of LIDT spots in different discharge conditions, it is found that the single-crater, which is formed by the discharge conditions of anode, which is covered by an oil film and with rectangular current waveform, has the most depth of heat affected zone (HAZ) comparing with other crater shapes when discharge energy is the same. The depth of HAZ is mainly depends on pulse duration when the discharge spot is single-crater. The results are analyzed.
Resumo:
The optical interference method is a promising technique for measuring temperature, density, and concentration in fluids. The non-intrusive and non-invasive nature of its optical techniques to the measured section are its most outstanding features. However, the adverse experiment environment, especially regarding shaking and vibrating, greatly restricts the application of the interferometer. In the present work, an optical diagnostic system consisting of a Mach-Zehnder interferometer (named after physicists Ludwig Mach) and an image processor has been developed that increases the measuring sensitivity compared to conventional experimental methods in fluid mechanics. An image processor has also been developed for obtaining quantitative results by using Fourier transformation. The present facility has been used in observing and measuring the mass transfer process of a water droplet in EAFP protein solution under microgravity condition provided by the satellite Shi Jian No. 8.
Resumo:
基于掺镧锆钛酸铅(PLZT)电光陶瓷材料的光学特性,提出了一种具有上下电极结构的光学相控阵高速光束扫描器。在理论上,分析了具有这种结构的光学相控阵的光束电光偏转特性和机制;在实验上,分析了掺镧锆钛酸铅材料的相位调制特性和损耗特性,制作了相关的光学相控阵器件,并构建了相应的测试系统,获得了光束在空间的角度偏转,与理论分析结果相符。
Resumo:
We present a destructive method for detecting and measuring subsurface damage of Nd-doped phosphate glasses. An instrument based on the dimple method - a destructive method - was developed. Subsurface damage depth produced in each fabrication procedure was obtained. We extend the surface roughness-subsurface damage relation to Nd-doped phosphate glasses. The constant ratio of subsurface damage and surface roughness was obtained as well. We also analyse the relation of abrasive size and subsurface damage experimentally. From a measurement of the surface roughness or abrasive size, one can obtain an accurate estimate of the damage layer thickness that must be eliminated by polishing or subsequent grinding operations. (C) 2007 Elsevier GmbH. All rights reserved.
Resumo:
By chopping a pump beam in conventional time-resolved Kerr rotation (TRKR) experiments and measuring the time evolution of M-shaped "major" hysteresis loops of magnetic linear dichroism (Delta MLD = MLDpump-on MLDpump-off), the differential MLD signal in the presence and the absence of the pump beam, we studied the dynamics of photo-enhanced magneto-crystalline anisotropy, and found that its very long recovering time (much longer than 13 ns) might reflect the nature of the coherent coupling between photo-excited holes and localized spins in the d shell of manganese.
Resumo:
We present a new way to meet the amount of strain relaxation in an InGaN quantum well layer grown on relaxed GaN by calculating and measuring its internal field. With perturbation theory, we also calculate the transition energy of InGaN/GaN SQWs as affected by internal fields. The newly reported experimental data by Graham et al. fit our calculations well on the assumption that the InGaN well layer suffered a 20% strain relaxation, we discuss the differences between our calculated results and the experimental data. Our calculation suggests that with the increase of indium mole fraction in the InGaN/GaN quantum well, the effect of polarization fields on the luminescence of the quantum well will increase. Moreover, our calculation also suggests that an increase in the quantum well width by only one monolayer can result in a large reduction in the transition energy. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
采用连续模拟降雨试验,对坡沟系统概化模型进行坡面沟蚀发育过程模拟,再现坡面片蚀—细沟侵蚀—切沟侵蚀演变过程。结合3种测量技术从测量精度、测量人员要求、数据处理、数据通用性、配套软件使用、前期投入、测量条件等几个方面入手,对比分析高精度GPS(Trimble 5700)、三维激光扫描仪(Leica HDS 3000)和测针板的3种测量方法的优缺点,同时对3种测量方法在沟蚀过程监测和侵蚀量估算方面进行对比研究。结果表明,激光扫描仪能很好地监测沟蚀演变过程,且对侵蚀量估算精度较高,误差仅为4.5%。高精度GPS也能很好地监测沟蚀演变过程,对侵蚀量估算精度误差为7.38%。测针板法不能很好的反映沟蚀演变过程,但是对于侵蚀量的估算可以满足日常要求,误差为-12.78%。
Resumo:
The interaction of silica with dipalmitoylphosphatidylcholine (DPPC) liposomes has been studied by detecting H-1 and 2D NOESY NMR spectra and measuring proton spin-lattice relaxation time (T-1). The antagonistic effect of aluminium citrate on silica has also been studied by measuring the proton T-1 values, The results show that silica particles mainly bind to the phosphate moiety of the polar headgroup of DPPC bilayers through hydrogen bonds between Si-OH and O-P groups, but they have no significant effect on the conformation of the choline group of the polar headgroup, The addition of silica particles decreases the mobilities of the hydrocarbon chains slightly, Proton T-1 data also indicate that aluminium citrate reduces the effect of silica, A possible mechanism for the toxicity of silica and the antagonistic effect of aluminium titrate on silica is suggested. (C) 1995 Academic Press Inc.
Resumo:
机器人标定是离线编程技术实用化的关键技术之一 ,测量手段是制约其发展的一个重要因素 .本文提出了一种简单实用的测量方法 .同时建立了具有完备性、比例性、连续性的 RH6 - A型机器人的真实运动学模型 .并根据测量结果 ,成功地辨识出了机器人的几何结构参数 ,提高了机器人的绝对精度 .
Resumo:
利用双目视觉信息系统实现三维空间中运动物体实时跟踪与测距。当运动目标超出视野范围时,可通过控制摄像机云台转动搜索目标。此外,还研究了在摄像头运动情况下,无需重新标定,即可实现运动物体测距的算法。这里,自适应背景建模法与CamShift算法用于实现运动物体的辨识与跟踪。实验结果证明了所提出的算法能够有效地追踪物体,并同时准确地测量它的三维位置。
Resumo:
提出了一种平面自由运动半物理仿真系统的设计,对系统仿真试验的初始条件形成过程进行了具体阐述。系统中应用了一种平面两自由度直角坐标运动装置,用于完成系统驱动及速度和位置控制,同时这种运动装置能够进行直角坐标跟随运动,并与其末端测量机构共同实现对平面自由运动物体的高精度大范围位姿测量。建立了系统的运动学模型,并设计相应的控制算法实现试验所需的运动过程,采用半闭环和闭环相结合的方法有效控制系统的末端累积误差;针对提出的复合测量方法,建立了测量原理的数学模型,并进行了精度分析和仿真计算。实验证明这种设计和相应的控制测量方法合理可行。
Resumo:
本文介绍了三维物体识别及姿态测定的一种新技术,从物体空间域模型出发,通过约束推理及几何推理,在物体三维信息部分给定的条件下,推断预测图象模型,并通过实测的图象数据反馈,推断出隐含在图象中未给定的三维信息,最终实现三维物体识别及姿态测定。整个系统在VICOM机上用C语言完成。
Resumo:
Along with the widespread and in-depth applications in petroleum prospecting and development, the seismic modeling and migration technologies are proposed with a higher requirement by oil industrial, and the related practical demand is getting more and more urgent. Based on theories of modeling and migration methods for wave equation, both related with velocity model, I thoroughly research and develop some methods for the goal of highly effective and practical in this dissertation. In the first part, this dissertation probes into the layout designing by wave equations modeling, focusing on the target-oriented layout designing method guided by wave equation modeling in complicated structure areas. It is implemented by using the fourth order staggered grid finite difference (FD) method in velocity-stress 2D acoustic wave equations plus perfectly matched layer (PML) absorbing boundary condition. To design target-oriented layout: (a) match the synthetic record on the surface with events of subsurface structures by analyzing the snapshots of theoretical model; (b) determine the shot-gather distance by tracking the events of target areas and measuring the receiving range when it reaches the surface; (c) restrict the range of valid shot-gather distance by drawing seismic windows in single shot records; (d) choose the best trace distance by comparing the resolution of prospecting targets from the simulated records with different trace distance. Eventually, we obtained the observation system parameters, which achieve the design requirements. In the second part, this dissertation presents the practical method to improve the 3D Fourier Finite Difference (FFD) migration, and carefully analyzes all the factors which influence 3D FFD migration’s efficiency. In which, one of the most important parameters of migration is the extrapolating step. This dissertation presents an efficient 3D FFD migration algorithm, which use FFD propagator to extrapolate wavefields over big layers, and use Born-Kirchhoff interpolator to image wavefields over small layers between the big ones. Finally, I show the effectiveness of this hybrid migration method by comparing migration results from 3D SEG/EAGE model with different methods.
Resumo:
There is increased interest in measuring kinetic rates, lifetimes, and rupture forces of single receptor/ligand bonds. Valuable insights have been obtained from previous experiments attempting such measurements. However, it remains difficult to know with sufficient certainty that single bonds were indeed measured. Using exemplifying data, evidence supporting single-bond observation is examined and caveats in the experimental design and data interpretation are identified. Critical issues preventing definitive proof and disproof of single-bond observation include complex binding schemes, multimeric interactions, clustering, and heterogeneous surfaces. It is concluded that no single criterion is sufficient to ensure that single bonds are actually observed. However, a cumulative body of evidence may provide reasonable confidence. 0 2002 Biomedical Engineering Society.