6 resultados para Blood samples

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

70.00% 70.00%

Publicador:

Resumo:

therapeutic drugs, vaccines and mechanisms of human diseases. Little is known about the normal levels of leukocyte subpopulations of Chinese rhesus macaques. To obtain these data, 100 blood samples from Chinese rhesus macaques were collected. The normal range of major leukocyte subpopulations, such as T lymphocytes, B lymphocytes, monocytes, myeloid dendritic cells (mDCs) and plasmacytoid dendritic cells (pDCs), were quantitatively analyzed by flow cytometry through BD trucount tubes. The influence of age and sex on the cell counts of leukocyte subpopulations was analyzed. The counts of CD3+ T cells, CD3+CD4+ T cells, CD3+CD8+ T cells and B cells decreased with age, but those of monocytes, mDCs and pDCs had no significant correlation with age. Significant differences existed in the cell counts of most leukocyte subpopulations between the male and female groups except pDCs. Furthermore the values of the females were higher than those of the males. The study provided basic information about the leukocyte subpopulations of Chinese rhesus macaques, and it may be valuable for immunobiological study of Chinese rhesus macaques. Cellular & Molecular Immunology. 2009;6(6):433-440.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The pig-tailed macaques are the only Old World monkeys known to be susceptible to human immunodeficiency virus type 1 (HIV-1) infection. We have previously reported that the TRIM5-Cyclophilin A (TRIMCyp) fusion in pig-tailed macaques (Macaca n

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As a relatively isolated and unique freshwater population, the Yangtze finless porpoise (Neophocaena phocaenoides asiaeorientalis) is the most endangered subpopulation of this species. The objective of this study was to improve our understanding of their reproductive endocrinology by measuring (radioimmunoassay) serum concentrations of FSH, LH, estradiol (E-2), progesterone (P-4) and testosterone (T-2) in free-ranging animals. Blood samples were collected from 66 Yangtze finless porpoises (41 males and 25 females) captured in the middle and lower reaches of the Yangtze River. Based on significant variation of serum T-2 concentrations in males with body length (BL) > 138 cm, we inferred that they were mature; in these animals, there were significant seasonal variations in serum T-2 concentrations, with the highest concentrations in March and April (502.0 +/- 319.8 ng/dL, mean +/- S.D.) and the lowest in December (79.4 +/- 83.2 ng/dL). Serum T-2 concentrations positively correlated with serum concentrations of LH and weakly correlated with serum concentrations of E-2, whereas there was a significant negative correlation between serum LH and FSH concentrations in males > 138 cm. The smallest apparently pregnant female porpoise had a BL of 130 cm. Serum P-4 concentrations ranged from 13.2 to 112.4 ng/mL (43.9 +/- 28.3 ng/mL) in pregnant females, and fluctuated under 1.0 ng/mL in non-pregnant females with BL > 130 cm. Serum LH concentrations were significantly higher in non-pregnant females > 130 cm versus those females < 130 cm. To our knowledge, this is the first study of endocrine-related maturity and seasonal breeding characteristics of the Yangtze finless porpoise. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sub-chronic toxicity experiment was conducted to examine tissue distribution and depuration of two microcystins (microcystin-LR and microcystin -RR) in the phytoplanktivorous filter-feeding silver carp during a course of 80 days. Two large tanks (A, B) were used, and in Tank A, the fish were fed naturally with fresh Microcystis viridis cells (collected from a eutrophic pond) throughout the experiment, while in Tank B, the food of the fish were M. viridis cells for the first 40 days and then changed to artificial carp feed. High Performance Liquid Chromatography (HPLC) was used to measure MC-LR and MC-RR in the M. viridis cells, the seston, and the intestine, blood, liver and muscle tissue of silver carp at an interval of 20 days. MC-RR and MC-LR in the collected Microcystis cells varied between 268-580 and 110-292 mug g(-1) DW, respectively. In Tank A, MC-RR and MC-LR varied between 41.5-99.5 and 6.9-15.8 mug g(-1) DW in the seston, respectively. The maximum MC-RR in the blood, liver and muscle of the fish was 49.7, 17.8 and 1.77 mug g(-1) DW, respectively. No MC-LR was detectable in the muscle and blood samples of the silver carp in spite of the abundant presence of this toxin in the intestines (for the liver, there was only one case when a relatively minor quantity was detected). These findings contrast with previous experimental results on rainbow trout. Perhaps silver carp has a mechanism to degrade MC-LR actively and to inhibit MC-LR transportation across the intestines. The depuration of MC-RR concentrations occurred slowly than uptakes in blood, liver and muscle, and the depuration rate was in the order of blood > liver > muscle. The grazing ability of silver carp on toxic cyanobacteria suggests an applicability of using phytoplanktivorous fish to counteract cyanotoxin contamination in eutrophic waters. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Syncytin is a placenta-specific protein and generally believed to play a pivotal role in syncytiotrophoblast morphogenesis. In this study, transcripts of this gene were quantified by real-time RT-PCR and the translated products were measured by an indirect immunofluorescence assay. Results showed that syncytin was found to be expressed in all nine leukemia and lymphoma cell lines studied albeit at different levels and in 43 peripheral blood samples of 57 leukemia or lymphoma patients. Neither the transcripts nor the translated syncytin was detected in blood samples of normal individuals. In conclusion, peripheral blood syncytin may serve as a marker for leukemia and lymphoma. ©

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An assay procedure utilizing pulsed amperometric detection at a platinum-particles modified electrode has been developed for the determination of cysteine and glutathione in blood samples following preliminary separation by reversed-phase liquid chromatography. A chemically modified electrode (CME) constructed by unique electroreduction from a platinum-salt solution to produce dispersed Pt particles on a glassy carbon surface was demonstrated to catalyze the electo-oxidation of sulfhydryl-containing compounds: DL-cysteine (CYS), reduced glutathione (GSH). When used as the sensing electrode in flow-system pulsed-amperometric detection (PAD), electrode fouling could be avoided using a waveform in which the cathodic reactivation process occurred at a potential of - 1.0 V vs. Ag/AgCl to achieve a cathodic desorption of atomic sulfur. A superior detection limit for these free thiols was obtained at a Pt particle-based GC electrode compared with other methods; this novel dispersed Pt particles CME exhibited high electrocatalytic stability and activity when it was employed as an electrochemical detector in FIA and HPLC for the determination of those organo-sulfur compounds.