27 resultados para Biogeochemistry|Analytical chemistry|Environmental science
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Amperometric biosensors based on surface modifications of electrodes are described. Cobalt porphyrins modified on glassy carbon and carbon fiber electrodes can greatly decrease the overpotential and increase the sensitivity of detection due to EC electroc
Resumo:
This review presents the latest advances in the application of microwave energy to analytical chemistry. The fundamental principles of microwave field interaction with the matter are presented and their significance for the chemist is discussed, followed by the basic principles of microwave equipment construction and operation. Examples of the techniques that utilized microwave energy for digestion, extraction, chemical reaction, preconcentration, and desorption of the analytical sample are presented. A separate section describes the examples of usage of microwave technology in catalysis, environmental, and nuclear chemistry and engineering.
Resumo:
This paper mainly reviewed the background, application and development on environmental electroanalytical chemistry, 79 literatures were cited.
Resumo:
A novel chemiluminescent immunoassay method based on gold nanoparticles was developed for the detection of microcystins (MCs). The immunoassay included three main steps: indirect competitive immunoreaction, oxidative dissolution of gold nanoparticles, and indirect determination for MCs with Au3+-catalysed luminol chemiluminesent system. The method has a wide working range (0.05-10 mu g L-1, r(2) = 0.9914), the limit of detection was determined to be 0.024 mu g L-1, which is much lower than the World Health Organization's proposed guidelines (1 mu g L-1) for drinking-water. The proposed method was applied to MC analysis in natural water and fish tissue samples, and most results in the proposed method were in agreement with the conventional indirect competitive enzyme-linked immunosorbent assay method, which indicated that the new chemiluminescent immunoassay was sensitive, reliable, and suitable for MC analysis in natural water and fish tissue samples.
Resumo:
A software has been developed for the peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) after high resolution gas chromatography coupled with mass spectrometry (HRGC/HRMS). Based on the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retention times of all PCDD and PCDF can be calibrated automatically and accurately. Therefore, it is very convenient to identify the peaks by comparing the retention of samples and the calibrated retention times of their chromatograms. Hence, this approach is very significant because it is impossible to obtain always a standard chromatogram and PCDD/F analysis are very expensive and time consuming. The calibration results can be transferred to Excel for calculation. The approach is a first step to store costly and environmentally relevant data for future application.
Resumo:
This paper summarizes some of the research and evaluation studies about mercury analysis in the environment during the past years in China. The main contents is as follows: 1) Determination of total mercury and speciation of mercury in air; 2) Storage and handling of water samples; 3) pre-treatment of solid samples; 4) Determination of total mercury and speciation of mercury in water and solid samples; 5) Certified reference materials.
Resumo:
Sediment core samples were collected in the largest urban Lake Donghu (Stations I and II) in China, and the activities of Pb-210, Ra-226 and Cs-137 were measured by gamma-ray spectrometry. The sedimentation rates, calculated by 210Pb constant rate of supply (CRS) model, ranged from 0.11 to 0.65 (average 0.39) cm(.)y(-1) at Station I, and from 0.21 to 0.78 (average 0.46) cm(.)y(-1) at Station II. Sedimentation rate calculated by Cs-137 as a time marker was 0.55 cm(.)y(-1) at Station II. Based on the average sedimentation rate, we obtained 769 and 147 t(.)y(-1) for nitrogen and phosphorus retentions in Lake Donghu sediments, respectively.
Resumo:
The ratio of methanol., water and trifluoroacetic acid ( TFA) was regulated to change the polarity and the pH of the rinse solution and the eluent, so as to improve the high performance liquid chromatography HPLC) detection method for trace microcystines (MCs) in natural water bodies. The results showed that 40 % similar to 45 % methanol-water solution containing 0. 1 % TFA could get good effects on the rinse of impurity, and 70% methanol-water solution containing 0. 1% TFA could elute all the MCs in solid phase extraction ( SPE) cartridge ( C-18), In this way. it is suggested that, in analysis of environmental samples with high concentration of impurity, impurity should be washed with 40% similar to 45% methanol-water solution containing 0. 1% TFA, and MCs should be eluted with 70% similar to 100% methanol-water solution containing 0. 1% TFA.
Resumo:
A comprehensive, critical and up-to-date review of analytical methods developed during the last decade for metals present in sea water is presented. Separate sections are devoted to singular and multimetal determinations. Furthermore, a critical comparison of relative merits or demerits of a particular procedure is made in terms of sensitivity, selectivity and precision. Various aspects of analysis of sea water samples for metals are summarized, and the future trends are discussed.
Resumo:
Mass spectrometry is not able to differentiate NOx and N2 from other interferences (e.g. CO and C2H4) in the deNOx reactions. In the present study, a quantitative method for analysis of NOx and N2 simultaneously in these reactions with an assisted converter operated at higher temperature under O2-rich condition, which eliminates the interferences, is developed. The NOx conversion from this method is comparable to the one from an Automotive Emission Analyser equipped with NOx electrochemical sensor. Two types of deNOx reactions are tested in terms of selectivity of N2 production. The application of this method is discussed.
Resumo:
Inorganic nanoparticles (NPs) with attractive electronic, optical, magnetic, thermal and catalytic properties have attracted great interest due to their important applications in physics, chemistry, biology, medicine, materials science and interdisciplinary fields. Biomolecule-NP hybrid systems, which combine recognition and catalytic properties of biomolecules with electronic, optical, magnetic and catalytic properties of NPs, are particularly new materials with synergistic properties originating from the components of the hybrid composites. The biomolecule-NP hybrid system has excellent prospects for interfacing biological recognition events with electronic signal transduction so as to design a new generation of bioelectronic devices with high sensitivity.
Resumo:
As a kind of novel green solvent, Room Temperature Ionic Liquids (RTILs) have been paid ever-increasing attentions in RTIL-based extraction for metal separation, since they have many unique proper-ties, such as non-volatile and non-flammable. The progress of that is mainly composed of the partition properties, mechanisms, defects, overcome methods and forecasts of the processes on the environmental analytical chemistry, has been reviewed.