16 resultados para Bibles for the blind.

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Any waterway with one end closed and the other open is generally called a blind channel. The main flow tends to expand, separate, and cause circulation at the mouth of blind channels. The main flow continuously transfers momentum and sediment into the circulation region through the turbulent mixing region (TMR) between them, thus leading to a large amount of sediment deposition in the blind channels. This paper experimentally investigated the properties of the water flow and sediment diffusion in TMR, demonstrating that both water flow and sediment motion in TMR approximately coincide with a similar structure as in the free mixing layer induced by a jet. The similarity functions of flow velocity and sediment concentration are then assumed, based on observation, and the resulting calculation of these functions is substantially facilitated. For the kind of low velocity flow system of blind channels with a finite width, a simple formula for the sediment deposition rate in blind channels is established by analyzing the gradient of crosswise velocity and sediment concentration in TMR.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Our previous studies have shown that the determination of coagulation rate constants by turbidity measurement becomes impossible for a certain operating wavelength (that is, its blind point) because at this wavelength the change in the turbidity of a dispersion completely loses its response to the coagulation process. Therefore, performing the turbidity measurement in the wavelength range near the blind point should be avoided. In this article, we demonstrate that the turbidity measurement of the rate constant for coagulation of a binary dispersion containing particles of two different sizes (heterocoagulation) presents special difficulties because the blind point shifts with not only particle size but also with the component fraction. Some important aspects of the turbidity measurement for the heterocoagulation rate constant are discussed and experimentally tested. It is emphasized that the T-matrix method can be used to correctly evaluate extinction cross sections of doublets formed during the heterocoagulation process, which is the key data determining the rate constant from the turbidity measurement, and choosing the appropriate operating wavelength and component fraction are important to achieving a more accurate rate constant. Finally, a simple scheme in experimentally determining the sensitivity of the turbidity changes with coagulation over a wavelength range is proposed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The extinction cross sections of a system containing two particles are calculated by the T-matrix method, and the results are compared with those of two single particles with single-scattering approximation. The necessity of the correction of the refractive indices of water and polystyrene for different incident wavelengths is particularly addressed in the calculation. By this means, the volume fractions allowed for certain accuracy requirements of single-scattering approximation in the light scattering experiment can be evaluated. The volume fractions calculated with corrected refractive indices are compared with those obtained with fixed refractive indices which have been rather commonly used, showing that fixed refractive indices may cause significant error in evaluating multiple scattering effect. The results also give a simple criterion for selecting the incident wavelength and particle size to avoid the 'blind zone' in the turbidity measurement, where the turbidity change is insensitive to aggregation of two particles.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Plateau zokor (Myospalax baileyi) is one of the blind subterranean mole rats that spend their life solely underground in scaled burrows. It is one of the special species of the Qinghai-Tibet plateau. In their burrows, oxygen is low and carbon dioxide is high and their contents fluctuate with the change of seasons, soil types, rain and depth of burrows. However, plateau zokors show successful adaptation to that extreme environment. In this study, their adapting mechanisms to the hypoxic hypercapnic environment were analyzed through the comparison of their blood-gas properties with that of pikas (Ochotona curzniae) and Sprague-Dawley rats. The results indicated that plateau zokors had higher red blood corpuscle counts (8.11 +/- 0.59 (10(12)/L)) and hemoglobin concentrations (147 +/- 9.85 g/L), but hematocrit (45.9 +/- 3.29%) and mean corpuscular volume (56.67 +/- 2.57 fL) were lower than the other rodents. Their arterial blood and venous blood pH were 7.46 +/- 0.07 and 7.27 +/- 0.07. Oxygen pressure in arterial blood of plateau zokors was about 1.5 times higher than that of pikas and rats, and it was 0.36 and 0.26 times in their venous blood. Partial pressure for carbon dioxide in arterial and venous blood of plateau zokors was 1.5-fold and 2.0-fold higher, respectively, than in rats and pikas. Oxygen saturation of plateau zokors was 5.7 and 9.3 times lower in venous blood than that of pikas and rats, respectively. As result, the difference of oxygen saturation in arterial blood to venous blood was 2- and 4.5-fold higher in plateau zokors as that of pikas and rats, respectively. In conclusion, plateau zokors had a high tolerance to pH changes in tissues, together with strong capabilities to obtain oxygen from their hypoxic-hypercapnic environment. (c) 2006 Published by Elsevier Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

原子力显微镜技术已在纳米成像中得到了普遍应用。但实验表明,AFM图像在水平方向分辨率较低,其中探针针尖形貌是影响扫描图像分辨率的关键因素之一。为了提高AFM扫描图像的分辨率,改善成像质量,一种可行的方法是通过建立探针模型后,重构扫描图像。在已有的探针建模方法中,普遍采用盲建模算法。针对目前盲建模算法中降噪阈值难以优化问题,提出了一种降噪阈值最优估计新方法。该方法可以使盲建模算法更准确地建立扫描方向上的探针形貌轮廓,进而完成3D探针模型。通过应用AFM探针扫描多空铝和标准栅格实验,介绍了探针针尖形貌精确建模的方法。然后使用数学形态学的腐蚀运算对标准栅格的AFM成像进行了重构,验证了上述方法的有效性。实验结果证明,重构后的图像中降低了探针针尖形貌的失真影响,可以显著改善扫描探针显微镜成像的水平分辨率。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the progress of prospecting, the need for the discovery of blind ore deposits become more and more urgent. To study and find out the method and technology for the discovery of blind and buried ores is now a priority task. New geochemical methods are key technology to discover blind ores. Information of mobile components related to blind ores were extracted using this new methods. These methods were tested and applied based on element' s mobile components migrating and enriched in geophysical-geochemical process. Several kinds of partial extraction techniques have tested based on element' s occurrence in hypergenic zone. Middle-large scale geochemical methods for exploration in forest and swamp have been tested. A serious of methods were tested and applied effetely about evaluation of regional geochemical anomaly, 1:25000 bedrock or soil geochemical methods sampling based on the net in dendritic water system instead of the normal net. 1. Element related with ores can be mobiled to migrate upwards and be absorpted by surface soil. These abnomal components can be concentrated by natural or artificial methods. These trace metalic ions partially exist in dissovlvable ion forms of active state, and partially have been absorbed by Fe-Mn oxide, soil and organic matter in the soil so that a series of reaction such as complex reaction have take place. Employing various partial extraction techniques, metallic ions related with the phase of the blind ores can be extracted, such as the technique of organic complex extraction, Fe-Mn oxide extraction and the extraction technique of metallic ions of various absorption phases. 2.1:200000 regional geochemical evaluation anomaly methods: Advantageous ore-forming areas were selected firstly. Center, concentration, morphological feature, belt of anomaly were choosed then. Geological and geochemical anomalies were combined. And geological and geochemical background information were restrained. Xilekuduke area in Fuyun sheet , Zhaheba area in Qiakuerte sheet, the west-north part in Ertai sheet and Hongshanzui anomaly in Daqiao sheet were selected as target areas, in Alertai, in the north of Xinjiang. in Xilekuduke area, 1:25000 soil geochemical methods sampling based on the net in dendritic water system was carried out. Cu anomaly and copper mineralization were determined in the center area. Au , Cu anomalies and high polarization anomaly were determined in the south part. Prospecting by primary halo and organic complex extraction were used to prognosis blind ore in widely rang outcrop of bedrock. 1:25000 bedrock or soil geochemical methods sampling based on the net in dendritic water system were used in transported overburden outside of mining area. Shallow seismic method and primary halo found a new blind orebody in mining area. A mineralization site was fou and outside of Puziwan gold mine, in the north of Shanxi province. Developing middle-large scale geochemical exploration method is a key technique based 1:200000 regional geochemical exploration. Some conditions were tested as Sampling density , distribution sites of sample, grain size of sample and occurrence of element for exploration. 1:50000 exploration method was advanced to sample clast sediment supplement clast sediment in valley. 1:25000 bedrock or soil geochemical methods sampling based on the net in dendritic water system was applied to sample residual material in A or C horizon. 1:2000 primary or soil halo methods used to check anomalies and determine mineralization. Daliang gold mineralization in the northern Moerdaoga was found appling these methods. Thermomagnetic method was tested in miniqi copper-polymetallic ore. Process methods such as grain size of sample, heated temperature, magnetic separating technique were tested. A suite of Thermomagnetic geochemical method was formed. This method was applied in Xiangshan Cu~Ni deposit which is cover by clast or Gobi in the eastern Xinjiang. Element's content and contrast of anomaly with Thermomagnetic geochemical method were higher than soil anomaly. Susceptibility after samples were heated could be as a assessment conference for anomaly. In some sectors thermo-magnetic Cu, Ni, Ti anomalious were found outside deposits area. There were strong anomal ies response up ore tested by several kind of partial extraction methods include Thermomagnetic, enzyme leach and other partial extractions in Kalatongke Cu-Ni deposit in hungriness area in the northern of Xinjiang. Element's anomalies of meobile were mainly in Fe-Mn oxide and salt. A Copper mineralization site in Xilekuduke anomaly area had been determined. A blind ore was foung by shallow seismic and geochemical method and a mineralization site was found outside this mining area in Puziwan gold deposit in shanxi province. A Gold mineralization site was found by 1:50000 geochemical exploration in Daliang, Inner Mongolia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In practical situations, the causes of image blurring are often undiscovered or difficult to get known. However, traditional methods usually assume the knowledge of the blur has been known prior to the restoring process, which are not practicable for blind image restoration. A new method proposed in this paper aims exactly at blind image restoration. The restoration process is transformed into a problem of point distribution analysis in high-dimensional space. Experiments have proved that the restoration could be achieved using this method without re-knowledge of the image blur. In addition, the algorithm guarantees to be convergent and has simple computation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A constrained high-order statistical algorithm is proposed to blindly deconvolute the measured spectral data and estimate the response function of the instruments simultaneously. In this algorithm, no prior-knowledge is necessary except a proper length of the unit-impulse response. This length can be easily set to be the width of the narrowest spectral line by observing the measured data. The feasibility of this method has been demonstrated experimentally by the measured Raman and absorption spectral data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The FOB-3, anew type fiber optic biosensor, is designed to rapidly detect a variety of biological agents or analytes with better stability, sensitivity and specificity. In order to detect Y. Pestis, a sandwich immunoassay was developed by using the purified antibody against antigen FI immobilized on polystyrene probes as the capture antibody and the monoclonal antibody-Cy5 conjugate as the detector. After a series of optimization for the stability, sensitivity and specificity of the FOB-3, 50-1000 ng/ml of antigen FI and 6 x 10(1)-6 x 10(7) CFU/ml Y. pestis could be detected constantly in about 20 min, and Y pestis could be detected specifically from Y. pseudotuberculosis, Y. enterocolitica, B. anthracis and E. coli. Then, 39 blind samples, including 27 tissues of mice infected with Y pestis and 12 tissues of healthy mice as negative control, were detected with the FOB-3. 92.6% infected tissues were identified from the tissues of healthy mice and the tissues containing more than 100 CFU/ml bacteria could be detected by the biosensor. The results demonstrated the feasibility of the FOB-3 as an effective method to detect Y. pestis rapidly and directly from the infected animal specimens with the advantage of portability, simple-operation as well as high sensitivity and specificity. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new blind loach of Triplophysa Rendahl 1933 was collected from a subterranean pool in a cave at Wulong County, Chongqing City, China, in November 2002. The new species, named Triplophysa rosa sp. nov., can be distinguished from its congeners by the following unique characters: eyes vestigial; 9 branched dorsal-fin rays; 12 branched pectoral-fin rays; 7 branched pelvic-fin rays; 6 branched anal-fin rays; 7 + 7 branched caudal-fin rays; distal margin of dorsal-fin concave; tip of pelvic-fin surpasses vertical level of anus; caudal-fin deeply forked; whole body scaleless and colourless. (c) 2005 The Fisheries Society of the British Isles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports the development of solar-blind aluminum gallium nitride (AlGaN) 128x128 UV Focal Plane Arrays (FPAs). The back-illuminated hybrid FPA architecture consists of an 128x128 back-illuminated AlGaN PIN detector array that is bump-mounted to a matching 128x128 silicon CMOS readout integrated circuit (ROIC) chip. The 128x128 p-i-n photodiode arrays with cuton and cutoff wavelengths of 233 and 258 nm, with a sharp reduction in response to UVB (280-320 nm) light. Several examples of solar-blind images are provided. This solar-blind band FPA has much better application prospect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

p(+)-pi-n(-)-n(+) ultraviolet photodetectors based on 4H-SiC homoepilayers have been presented. The growth of the 4H-SiC homoepilayers was carried out in a LPCVD system. The size of the active area of the photodetectors was 300 x 300 mu m(2). The dark and illuminated I-V characteristics had been measured at reverse biases form 0 to 20 V at room temperature, and the illuminated current was at least two orders of magnitude than that of dark current below 13 V bias. The peak value zones of the photoresponse were located at 280-310 nm at different reverse biases, and the peak value located at 300 nm was 100 times greater than the cut-off response value in 380 nm at a bias of 10V, which showed the device had good visible blind performance. A small red-shift about 5 nm on the peak responsivity occurred when reverse bias increased from 5 to 15 V. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of the current sensor in power equipment may become worse affected by the environment. In this paper, based on ICA, we propose a method for on-line verification of the phase difference of the current sensor. However, not all source components are mutually independent in our application. In order to get an exact result, we have proposed a relative likelihood index to choose an optimal result from different runs. The index is based on the maximum likelihood evaluation theory and the independent subspace analysis. The feasibility of our method has been confirmed by experimental results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of the current sensor in power equipment may become worse affected by the environment. In this paper, based on ICA, we propose a method for on-line verification of the phase difference of the current sensor. However, not all source components are mutually independent in our application. In order to get an exact result, we have proposed a relative likelihood index to choose an optimal result from different runs. The index is based on the maximum likelihood evaluation theory and the independent subspace analysis. The feasibility of our method has been confirmed by experimental results.