65 resultados para Aragonite (integrated peak area)
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
This paper describes a novel method that applies pressure-assisted field-amplified sample injection with reverse migrating micelles (PA-FASI-RMM) for the online concentration of neutral analytes in MEKC with a low-pH BGE. After injection of a plug of water into the separation capillary, negative voltage and positive pressure were simultaneously applied to initialize PA-FASI-RMM injection. The hydrodynamic flow generated by the positive pressure compensated the reverse EOF in the water plug and allowed the water plug to remain in the capillary during FASI with reverse migrating micelles (FASI-RMM) to obtain a much longer injection time than usual, which improved stacking efficiency greatly. Equations describing this injection mode were introduced and were supported by experimental results. For a 450-s online PA-FASI-RMM injection, three orders of magnitude sample enhancement in terms of peak area could be observed for the steroids and an achievement of detection limits was between 1 and 10 ng/mL.
Resumo:
ZnO thin films were implanted at room temperature with 80 keV N+ or 400 keV Xe+ ions. The implantation fluences of N+ and Xe+ ranged from 5.0 x 10(14) to 1.0 x 10(17)/cm(2), and from 2.0 x 10(14) to 5.0 x 10(15)/cm(2), respectively. The samples were analyzed using Raman spectroscopy and the Raman scattering modes of the N- and Xe-ion implanted samples varying with implantation fluences were investigated. It was found that Raman peaks (bands) at 130 and 578 cm(-1) appeared in the spectra of ion-implanted ZnO samples, which are independent of the ion species, whereas a new peak at 274 cm(-1) was found only in N-ion implanted samples, and Raman band at 470 cm(-1) was found clearly in Xe-ion implanted samples. The relative intensity (peak area) increased with the increasing of the implantation fluences. From the comparison of the Raman spectra of N- and Xe-ion implanted ZnO samples and considering the damage induced by the ions, we analyzed the origin of the observed new Raman peaks (bands) and discussed the structure changes of ZnO films induced by N- and Xe-ion implantations.
Resumo:
An apparatus including a rotary-type injector was designed for quantitative sample injection in capillary electrophoresis (CE), in which both pressurized flow and electroosmotic flow were used to drive the background electrolyte solution. A relative standard deviation of peak area of lower than 1% was achieved by using this apparatus. The effects of back-pressure regulator, restrictor, and applied voltage on separation efficiency and resolution were investigated. The utility of this apparatus in both micro-HPLC and pressurized capillary electrochromatography (pCEC) was also demonstrated.
Resumo:
Surface replacement reaction of thiol-derivatized, single-stranded oligonucleotide (HS-ssDNA) by mercaptohexanol (MCH) is investigated in order to reduce surface density of the HS-ssDNA adsorbed to Au(111) surface. Cyclic voltammograms (CVs) and scanning tunneling microscopy (STM) are employed to assess the composition and state of these mixed monolayers. It is found that each CV of mixed self-assembled monolayers (SAMs) only shows a single reductive desorption peak, which suggests that the resulted, mixed SAMs do not form discernable phase-separated domains. The peak potential gradually shifts to negative direction and the peak area increases step by step over the whole replacement process. By analyzing these peak areas, it is concluded that two MCH molecules will replace one HS-ssDNA molecule and relative coverage can also be estimated as a function of exposing time. The possible mechanism of the replacement reaction is also proposed. The DNA surface density exponentially reduces with the exposing time increasing, in other words, the replacement reaction is very fast in the first several hours and then gradually slows down. Moreover, the morphological change in the process is also followed by STM.
Resumo:
CH4 and CO oxidation reaction on perovskite-like oxides La2-xSrxMO4 (0.01 <= x <= 1.0; M = Cu, Ni) was investigated from cyclic voltammetry method, finding that for suprafacial CO oxidation reaction, the catalyst activity has a close correlation to the area of redox peaks measured in the cyclic voltammetry, the larger the peak area is, the higher the activity will be, while for interfacial CH4 oxidation reaction, the activity depends mainly on the difference in redox potentials (Delta E), and the smaller the difference in redox potentials is, the higher the activity will be.
Resumo:
In this report, we describe an improved thermal fractionation technique used to characterize the polydispersity of crystalline ethylene sequence length (CESL) of ethylene/alpha -olefin copolymers. After stepwise isothermal crystallization, the crystalline ethylene sequences are sorted into groups by their lengths. The CESLs are estimated using melting points of known hydrocarbons. The content of each group is determined using the calibrated peak area. The statistical terms: the arithmetic mean (L) over bar (n), the weighted mean (L) over bar (w) and the broadness index I = (L) over bar (w)/(L) over bar (n) are used to describe the distribution of CESL. Results show that improved thermal fractionation technique can quantitatively characterize the polydispersity of CESL with a high degree of accuracy.
Resumo:
The essential oil in purple magnolia leaves was extracted by steam distillation approaches. The oil obtained was dried with anhydrous magnesium sulfate. According to the analysis of gas chromatography/mass spectrometry, more than 40 peaks were separated and 32 compounds were identified. The identified constituents represent 95% of the peak area of the essential oil. The main compounds were germacrene-D, santolina triene, caryophyllene, 1,3,7-octatriene, 3,7-dimethyl, and camphene, etc.
Resumo:
Poly(butylene succinate), (PBS) with different molecular weight was gamma -irradiated at different temperatures and various doses. PBS with high molecular weight and smaller peak area of crystal melting gave the highest gel content at the same temperatures and dose. A two-step irradiation (irradiation in molten state after irradiation at room temperature) gave the highest gel content in different conditions. This is due to the formation of network structure by pre-irradiation at room temperature that leads to less degradation. PBS prepared by two step irradiation was effective for improvement of heat stability because of high gel content formation. Unirradiated PBS sheets broke immediately at 110 degrees, while the irradiated sample (gel fraction, 50%) by a two step-method did not break even up to 200 minutes at 130 degreesC. The PBS sheets are biodegradable even after crosslinking.
Resumo:
An electrochemical technique for the real-time detection of hydrogen peroxide (H2O2) was employed to describe respiratory burst activity (RBA) of phagocytes in plasma which can be used to evaluate the ability of immune system and disease resistance. The method is based upon the electric current changes, by redox reaction on platinum electrode of extracellular hydrogen peroxide (H2O2) released from phagocytes stimulated by the zymosan at 680 mV direct current (d.c.). Compared with the control, activation of respiratory burst by zymosan particles results in a high amperometric response, and a current peak was obtained during the whole monitoring process. The peak current was proved by addition Of Cu2+ and other controls, to be the result of intense release of H2O2 from phagocytes. The peak area was calculated and used to evaluate the quantity of effective H2O2, which represents the quantity of H2O2 beyond the clearance of related enzymes in plasma. According to Faraday's law, the phagocytes' ability of prawns to generate effective H2O2 was evaluated from 1.253 x 10(-14) mol/cell to 6.146 x 10(-14) mol/cell, and carp from 1.689 x 10(-15) Mol/Cell to 7.873 x 10(-1)5 mol/cell. This method is an acute and quick detection of extracellular effective H2O2 in plasma and reflects the capacity of phagocytes under natural conditions, which could be applied for selecting species and parents with high immunity for breeding in aquaculture. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
We developed an HPLC method for analysis of the monosaccharide composition of fucoidans. The fucoidan was hydrolyzed into monosaccharides with 2 mol/L trifluoroacetic acid. Using ribose as the internal standard, the monosaccharide derivatives, obtained with 1-Phenyl-3-methyl-5-pyrazolone (PMP), were separated by reverse-phase HPLC using a gradient elution process, and monitored by ultraviolet detection at 245 nm. In the concentration range of 0.1-2.0 mmol/L, the peak area of each monosaccharide had a good linear relationship with its concentration (r(2)> 0.998). The average recoveries of mannose, rhamnose, glucuronic acid, glucose, galactose, xylose, and fucose were 86.2%, 95.1%, 62.5%, 102.0%, 94.8%, 66.6%, and 105.1%, respectively. This method was accurate and had good reproducibility and could be used to determine the monosaccharide contents of fucoidans.
Resumo:
A novel labeling reagent 1-(2-naphthyl)-3-methyl-5-pyrazolone (NMP) coupled with capillary electrophoresis (CE) with DAD detection for the determination of carbohydrates has been developed. The chromophore in the 1-phenyl-3-methyl-5-pyrazolone (PMP) reagent is replaced by naphthyl functional group, which results in a reagent with very high molar absorptivity (epsilon(251nm) = 5.58 x 10(4) L mol(-1) cm(-1)). This pen-nits NMP-labeled carbohydrates to be detected with UV absorbance in standard 50-mu m-i.d. fused silica capillaries by zone electrophoresis. in this mode, nanomolar concentrations of detection limits are obtained. The method for the derivatization. of carbohydrates with NMP is simplified. The derivatization reaction is rapid and mild in the presence of ammonia catalyst without further transfer steps. Nine monosaccharide derivatives such as mannose, galacturonic acid, glucuronic acid, rhamnose, glucose, galactose, xylose, arabinose and fucose can successfully be detected in CE mode. Good reproducibility can be obtained with relative standard deviation (R.S.D.) values of the migration times and peak area, respectively, from 0.44 to 0.48 and from 3.2 to 4.8. Furthermore, the developed method has been successfully applied to the analysis of carbohydrates in the hydrolyzed rape bee pollen samples. (C) 2008 Published by Elsevier B.V.
Resumo:
Pharmacologically active xanthone compounds isolated from Swertia przewalskii pissjauk were well separated by capillary electrophoresis (CE) within 5 min, using a running buffer of 25 mM disodium tetraborate at pH 9.0. Quantitative determination was shown to be possible because regression equations revealed a linear relationship between the peak area of each constituent and its concentration, with correlation coefficients of 0.9972-0.9994. The relative standard deviations were between 0.44%-0.73% for migration times and 2.52%-4.28% for peak areas. The dissociation constant of 1,7-O-beta-D-glucopyranosyl-8-hydroxy-3,7-dimethoxyxanthone, 1,8-dihydroxy-3, 7-dimethoxy-xanthone and 1,7-dihydroxy-3,8-dimethoxyxanthone were also measured by the CE method, giving a value of 9.04, 8.94, and 8.59, respectively.
Resumo:
Separation of small peptides on ion-exchange capillary electrochromatography (IE-CEC) with strong cation-exchange packing (SCX) as stationary phase was investigated. It was observed that the number of theoretical plates for small peptides varied from 240 000 to 460 000/m, and the relative standard deviation for t(0) and the migration time of peptides were less than 0.57% and 0.27%, respectively for ten consecutive runs. Unusually high column efficiency has been explained by the capillary electrophoretic stacking and chromatofocusing phenomena during the injection and separation of positively charged peptides. The sample buffer concentration had a marked effect on the column efficiency and peak area of the retained peptides. The influences of the buffer concentration and pH value as well as the applied voltage on the separation were investigated. It has been shown that the electrostatic interaction between the positively charged peptides and the SCX stationary phase played a very important role in IE-CEC, which provided the different separation selectivity from those in the capillary electrophoresis and reversed-phase liquid chromatography. A fast separation of ten peptides in less than 3.5 min on IE-CEC by adoption of the highly applied voltage was demonstrated. (C) 2000 Elsevier Science B.V. All rights reserved.
Resumo:
Capillary zone electrophoresis was used to monitor the interaction between bilirubin and human serum albumin. Cord blood serum samples were injected directly into an uncoated fused-silica capillary (30 cm x 50 mu m i.d.) and separation was accomplished within 4 min without extensive sample pretreatment. The most suitable running buffer to separate free bilirubin from albumin bound bilirubin was found to contain 1.0 mmol/L EDTA, 5% acetonitrile and 15 mmol/L phosphate with pH adjusted to 8.4. Approximately two bilirubin dianions could be bound per human serum albumin molecule in the cord blood serum. The binding constant was estimated to be 1.1 x 10(5) (L/mol) at 25 degrees C and pH 8.4. The peak area ratio of free bilirubin to total bilirubin can be used to determine the bilirubin binding capacity of cord blood serum for the concentration range of total bilirubin from 204 to 340 mu mol/L using 1:5 diluted cord blood seras. Copyright (C) 1999 John Wiley & Sons, Ltd.
Resumo:
Pressurized capillary electrochromatography (pCEC) and electrospray ionization-mass spectrometry (ESI-MS) have been hyphenated for protein analysis. Taken cytochrome c, lysozyme, and insulin as samples, the limits of detection (LODs) for absolute concentrations are 10(-11) mol (signal-to-noise ratio S/N = 3) with relative standard deviations (RSDs) of retention time and peak area, respectively, of less than 1.7% and 4.8%. In order to improve the detection sensitivity, on-line concentration by field-enhanced sample-stacking effect and chromatographic zone-sharpening effect has been developed, and parameters affecting separation and detection, such as pH and electrolyte concentration in the mobile phase, separation voltage, as well as enrichment voltage and time, have been studied systematically. Under the optimized conditions, the LODs of the three proteins could be decreased up to 100-fold. In addition, the feasibility of such techniques has been further demonstrated by the analysis of modified insulins at a concentration of 20 mu g/mL.