10 resultados para Alkalinity, potentiometric

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A plasticized Cr3+ ion sensor by incorporating 2,3,8,9-tetraphenyl-1,4,7,10-tetraazacyclododeca-1,3,7,9-tetraene (TTCT) ionophore exhibits a good potentiometric response for Cr3+ over a wide concentration range (1.0×10-6-1.0×10-1 M) with a slope of 19.5 mV per decade. The sensor response is stable for at least three months. Good selectivity for Cr3+ in comparison with alkali, alkaline earth, transition and heavy metal ions, and minimal interference are caused by Li+, Na+, K+, Co2+, Hg2+, Ca2+, Pb2+ and Zn2+ ions, which are known to interfere with other chromium membrane sensors. The TTCT-based electrode shows a fast response time (15 s), and can be used in aqueous solutions of pH 3 - 5.5. The proposed sensor was used for the potentiometric titration of Cr3+ with EDTA and for a direct potentiometric determination of Cr3+ content in environmental samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of glucose is possible with the enzymatic reaction of glucose oxidase and potentiometric detection. The signal is proportional to the concentration up to 50 mg/dl. This value is fixed by the concentration of oxygen in the sample. By adding catalase, concentrations up to 2000 mg/dl are detectable. The steepness of the calibration curve is not affected by oxygen concentrations greater than 4 mg/l. In contrast to amperometric sensors, an influence of deposits on the electrodes surface on the signal cannot be found with potentiometric sensors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with determining points of zero charge of natural and Na+-saturated mineral kaolinites using two methods: (1) acid-base potentiometric titration was employed to obtain the adsorption of H+ and OH- on amphoteric surfaces in solutions of varying ionic strengths in order to determinate graphically the point of zero net proton charge (PZNPC) defined equally as point of zero salt effect (PZSE); (2) mass titration curve at different electrolyte concentrations in order to estimate PZNPCs by interpolation and to compare with those determined by potentiometric titrations. The two methods involved points of zero charge approximately similar for the two kaolinites between 6.5-7.8, comparable to those reported previously and were in the range expected for these clay minerals. The comparison of potentiometric surface titration curves obtained at 25 °C and those published in the literature reveals significant discrepancies both in the shape and in the pH of PZNPCs values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

the salt ritration metod was evaluated as a method to determine zpc in comparison with the potentiometric titration method for 26 soil with variable charge clays,i.e.,Oxisols and Ultisols from Thailand and Andisols from Japan. In addition to the determination of ST-pH0 as the zero point of charge, a calculation procedure was adopted here in order to acquire more information from the titration curve . fuithermore, for the purpose of cross-checking of zpc determined by the pt method, the st procedure was successively applied to the samples analyzed by the pt method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stability constants of M-L binary system and M-L-L' (M = La3+ similar to Yb3+, Y3+ and Ca2+; L= DL-malic aicd, L' = L-hydroxyproline) ternary system were determined by pH-(0)-tentiometric method under the simulating physiological condition(37 degrees C, I=0.15 mol/L NaCl). The complex species MpLqLr'H-s(abbr as pqrs) in the sytems were ascertained by program COMPLEX. The results show that there are three species(1101, 1100 and 1200) in M-L binary system and one species(1010) in M-L' binary system. In addition to the above four species, a new species, 1112 was found in the M-L-L' ternary system, which is the only species of mixed ligands. Rare earth ions form more stable complexes than calcium ion does and the stability differences between their complexes in the ternary system are less than that in the binary system. The distributions of all the species in La-L-L' ternary system vs pH are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of field observation carried out in May 2003 were used to examine pH and total alkalinity behaviors in the Changjiang Estuary. It was showed that PH and total alkalinity took on clear spatial variations in values with the minima in the low salinity region. Like salinity, transect distributions of PH and total alkalinity (TA) in a downriver direction had a sharp gradient each. These gradients appeared in such a sequence that the TA gradient was earlier than salinity and PH gradients, and the salinity gradient was earlier than the PH gradient. These distribution characteristics seemed to be strongly influenced by the mixing process of freshwater and seawater, for both PH and total alkalinity had significant linear relationships with salinity and temperature. For PH, phytoplankton activities also had a significant impact upon its spatial distribution. During a period of 48 h, PH and total alkalinity changed within wide ranges for every layer of the two anchor stations, namely, Stas 13 and 20, which were located at the mixed water mass and seawater mass, respectively. For both Stas 13 and 20, PH and TA fluctuation of every layer could be very wide during a 4 h period. As a whole, the data of the two anchor stations showed that neither variations in salinity and temperature nor phytoplankton activities were the main factors strongly influencing the total alkalinity temporal variability on a small time scale. The data of Sta. 20 implied that both salinity variation and phytoplankton activities had a significant influence on PH temporal variability, but the same conclusion could not be drawn from the data of Sta. 13.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast, sensitive and reliable potentiometric stripping analysis (PSA) is described for the selective detection of the marine pathogenic sulfate-reducing bacterium (SRB). Desulforibrio caledoiensis. The chemical and electrochemical parameters that exert influence on the deposition and stripping of lead ion, such as deposition potential, deposition time and pH value were carefully studied. The concentration of SRB was determined in acetate buffer solution (pH 5.2) under the optimized condition (deposition potential of -1.3 V. deposition time of 250 s, ionic strength of 0.2 mol L-1 and oxidant mercury (II) concentration of 40 mg L-1). A linear relationship between the stripping response and the logarithm of the bacterial concentration was observed in the range of 2.3 x 10 to 2.3 x 10(7) cfu mL(-1). In addition, the potentiometric stripping technique gave a distinct response to the SRB, but had no obvious response to Escherichia coli. The measurement system has a potential for further applications and provides a facile and sample method for detection of pathogenic bacteria. (C) 2010 Elsevier B.V. All rights reserved.