128 resultados para hormone-sensitive lipase


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Growth hormone (GH) effectively promotes seawater (SW) adaptation in salmonids, but little is known of its effect in tilapias. Experiments were performed to investigate the effects of recombinant eel GH (reGH) on osmoregulatory actions and ultrastructural features of gill chloride cells in juvenile tilapia, Oreochromis niloticus. Tilapia showed a markedly improved SW survival, when directly transferred from freshwater (FW) to 62.5% SW 24h after a single reGH injection (0.25 or 2.5 mu g g(-1)) or 3 reGH injections (0.25 mu g g(-1) every other day). Plasma Na+ and Mg2+ levels were significantly reduced by reGH (0.25 and 2.5 mu g g(-1)) compared with saline injections; Ca2+ concentrations were reduced significantly by high dose of reGH (2.5 mu g g(-1)) after SW transfer. However, fish failed to survive more than 24h when directly transferred to 70 % SW, although the fish treated with reGH could survive longer than the controls. When examined by electron microscopy, the chloride cells were identified as mitochondrion-rich and an extensive tubular system was induced by GH treatment. The results of the present study suggest that, similar to its effect on salmonids, GH also exerts acute osmoregulatory actions and enhances SW adaptation in juvenile tilapia. GH also stimulates the differentiation of chloride cells toward SW adaptation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the LAMP method, a highly specific and sensitive detection system for genetically modified soybean (Roundup Ready) was designed. In this detection system, a set of four primers was designed by targeting the exogenous 35S epsps gene. Target DNA was amplified and visualized on agarose gel within 45 min under isothermal conditions at 65 degrees C. Without gel electrophoresis, the LAMP amplicon was visualized directly in the reaction tube by the addition of SYBR Green I for naked-eye inspection. The detection sensitivity of LAMP was 10-fold higher than the nested PCR established in our laboratory. Moreover, the LAMP method was much quicker, taking only 70 min, as compared with 300 min for nested PCR to complete the analysis of the GM soybean. Compared with traditional PCR approaches, the LAMP procedure is faster and more sensitive, and there is no need for a special PCR machine or electrophoresis equipment. Hence, this method can be a very useful tool for GMO detection and is particularly convenient for fast screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leptin, an adipocyte-derived hormone, plays all important role in body energy homeostasis. Plateau pika (Ochotona curzoniae), an endemic and keystone species living only at 3000-5000 in above sea level oil Qinghai-Tibet Plateau, is a typically high hypoxia and low temperature tolerant mammal with high resting metabolic rate (RMR), non-shivering thermogenesis (NST), and high ratio of oxygen utilization to cope with harsh plateau environment. To explore the molecular mechanism of ecological acclimation in plateau pika, we first cloned pika leptin cDNA and compared its mRNA expression in different altitudes (3200 and 3900 in) using real-time RTPCR (Taqman probe) technology. The full-length pika leptin cDNA was 3015 with 504 bp open-reading frame encoding the precursor peptide of 167 amino acids including 21 residues of signal peptide. Pika leptin was 70-72% homologous to that of other species and was of similarly structural characteristics with other species. The pika-specific genetic diversity in leptin sequence occurred at twenty sites. With the increase in attitude, there were larger fat store and high level of ob gene expression in plateau pika. Our results indicated that leptin is sensitive to cold and hypoxia plateau environment and may play one of important roles in pika's ecological adaptation to harsh plateau environment. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pre-column derivatization method for the sensitive determination of amino acids and peptides using the tagging reagent 1,2-benzo-3,4dihydrocarbazole-9-ethyl chloroformate (BCEOC) followed by high-performance liquid chromatography with fluorescence detection has been developed. Identification of derivatives was carried out by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS/MS). The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent was replaced by 1,2-benzo-3,4-dihydrocarbazole functional group, which resulted in a sensitive fluorescence derivatizing reagent BCEOC. BCEOC can easily and quickly label peptides and amino acids. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography. The derivatives showed an intense protonated molecular ion corresponding m/z (M + H)(+) under electrospray ionization (ESI) positive-ion mode with an exception being Tyr detected at negative mode. The collision-induced dissociation of protonated molecular ion formed a product at m/z 246.2 corresponding to the cleavage of C-O bond of BCEOC molecule. Studies on derivatization demonstrate excellent derivative yields over the pH 9.0-10.0. Maximal yields close to 100% are observed with a 3-4-fold molar reagent excess. Derivatives exhibit strong fluorescence and extracted detzvatization solution with n-hexane/ethyl acetate (10:1, v/v) allows for the direct injection with no significant interference from the major fluorescent reagent degradation by-products, such as 1,2-benzo-3,4-dihydrocarbazole-9-ethanol (BDC-OH) (a major by-product), mono- 1,2-benzo-3,4-dihydrocarbazole-9-ethyl carbonate (BCEOC-OH) and bis-(1,2-benzo-3,4-dihydrocarbazole-9-ethyl) carbonate (BCEOC)(2). In addition, the detection responses for BCEOC derivatives are compared to those obtained with previously synthesized 2-(9-carbazole)-ethyl chloroformate (CEOC) in our laboratory. The ratios AC(BCEOC)/AC(CEOC) = 2.05-6.51 for fluorescence responses are observed (here, AC is relative fluorescence response). Separation of the derivatized peptides and amino acids had been optimized on Hypersil BDS C-18 column. Detection limits were calculated from 1.0 pmol injection at a signal-to-noise ratio of 3, and were 6.3 (Lys)-177.6 (His) fmol. The mean interday accuracy ranged from 92 to 106% for fluorescence detection with mean %CV < 7.5. The mean interday precision for all standards was < 10% of the expected concentration. Excellent linear responses were observed with coefficients of > 0.9999. Good compositional data could be obtained from the analysis of derivatized protein hydrolysates containing as little as 50.5 ng of sample. Therefore, the facile BCEOC derivatization coupled with mass spectrometry allowed the development of a highly sensitive and specific method for the quantitative analysis of trace levels of amino acids and peptides from biological and natural environmental samples. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and sensitive method for the determination of short and long-chain fatty acids using high-performance liquid chromatography with fluorimetric detection has been developed. The fatty acids were derivatized to their corresponding esters with 9-(2-hydroxyethyl)-carbazole (HEC) in acetonitrile at 60 degreesC with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride as a coupling agent in the presence of 4-dimethylaminopyridine (DMAP). A mixture of esters of C-1-C-20 fatty acids was completely separated within 38 min in conjunction with a gradient elution on a reversed-phase C-18 column. The maximum fluorescence emission for the derivatized fatty acids is at 365 nm (lambda (ex) 335 nm). Studies on derivatization conditions indicate that fatty acids react proceeded rapidly and smoothly with HEC in the presence of EDC and DMAP in acetonitrile to give the corresponding sensitively fluorescent derivatives. The application of this method to the analysis of long chain fatty acids in plasma is also investigated. The LC separation shows good selectivity and reproducibility for fatty acids derivatives. The R.S.D. (n = 6) for each fatty acid derivative are <4%. The detection limits are at 45-68 fmol levels for C-14-C-20 fatty acids and even lower levels for

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diosgenyl saponins were regio selectively acylated by Novozyme 435 with vinyl esters as acylating agents in THF to afford the corresponding mono- or diacyl diosgenyl saponins. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The p16 tumor suppressor gene is inactivated by promoter region hypermethylation in many types of tumor. Recent studies showed that aberrant methylation of the p16 gene is an early event in many tumors, especially in lung cancer, and may constitute a new biomarker for early detection and monitoring of prevention trials. We detected tumor-associated aberrant hypermethylation of the p16 gene in plasma and tissue DNA from 153 specimens using a modified semi-nested methylation-specific PCR (MSP) combining plastic microchip electrophoresis or slab gel electrophoresis, respectively. Specimens were from 79 lung cancer patients, 15 abdominal tumor patients, 30 positive controls and 30 negative controls. The results showed that the positive rate obtained by microchip electrophoresis was more than 26.6% higher and the same speciticity was kept when compared with slab gel electrophoresis. The microchip electrophoresis can rapidly and accurately analyze the PCR products of methylated DNA and obviously improve the positive rate of diagnosis of cancer patients when compared with gel electrophoresis. This method with the high assay sensitivity might be used for detection of methylation of p16 gene and even to facilitate early diagnosis of cancer patients. (C) 2004 Elsevier B.V. All rights reserved.