158 resultados para Chamber dilation
Resumo:
We report a measurement of high-p(T) inclusive pi(0), eta, and direct photon production in p + p and d + Au collisions at root s(NN) = 200 GeV at midrapidity (0 < eta < 1). Photons from the decay pi(0) -> gamma gamma were detected in the barrel electromagnetic calorimeter of the STAR experiment at the Relativistic Heavy Ion Collider. The eta -> gamma gamma decay was also observed and constituted the first eta measurement by STAR. The first direct photon cross-section measurement by STAR is also presented; the signal was extracted statistically by subtracting the pi(0), eta, and omega(782) decay background from the inclusive photon distribution observed in the calorimeter. The analysis is described in detail, and the results are found to be in good agreement with earlier measurements and with next-to-leading-order perturbative QCD calculations.
Resumo:
Parity (P)-odd domains, corresponding to nontrivial topological solutions of the QCD vacuum, might be created during relativistic heavy-ion collisions. These domains are predicted to lead to charge separation of quarks along the orbital momentum of the system created in noncentral collisions. To study this effect, we investigate a three-particle mixed-harmonics azimuthal correlator which is a P-even observable, but directly sensitive to the charge-separation effect. We report measurements of this observable using the STAR detector in Au + Au and Cu + Cu collisions at root s(NN) = 200 and 62 GeV. The results are presented as a function of collision centrality, particle separation in rapidity, and particle transverse momentum. A signal consistent with several of the theoretical expectations is detected in all four data sets. We compare our results to the predictions of existing event generators and discuss in detail possible contributions from other effects that are not related to P violation.
Resumo:
We present a measurement of pi(+)pi(-)pi(+)pi(-) photonuclear production in ultraperipheral Au-Au collisions at root s(NN) = 200 GeV from the STAR experiment. The pi(+)pi(-)pi(+)pi(-) final states are observed at low transverse momentum and are accompanied by mutual nuclear excitation of the beam particles. The strong enhancement of the production cross section at low transverse momentum is consistent with coherent photoproduction. The pi(+)pi(-)pi(+)pi(-) invariant mass spectrum of the coherent events exhibits a broad peak around 1540 +/- 40 MeV/c(2) with a width of 570 +/- 60 MeV/c(2), in agreement with the photoproduction data for the rho(0)(1700). We do not observe a corresponding peak in the pi(+)pi(-) final state and measure an upper limit for the ratio of the branching fractions of the rho(0)(1700) to pi(+)pi(-) and pi(+)pi(-)pi(+)pi(-) of 2.5% at 90% confidence level. The ratio of rho(0)(1700) and rho(0)(770) coherent production cross sections is measured to be 13.4 +/- 0.8(stat.) +/- 4.4(syst.)%.
Resumo:
We present the first measurements of identified hadron production, azimuthal anisotropy, and pion interferometry from Au + Au collisions below the nominal injection energy at the BNL Relativistic Heavy-Ion Collider (RHIC) facility. The data were collected using the large acceptance solenoidal tracker at RHIC (STAR) detector at root s(NN) = 9.2 GeV from a test run of the collider in the year 2008. Midrapidity results on multiplicity density dN/dy in rapidity y, average transverse momentum < p(T)>, particle ratios, elliptic flow, and Hanbury-Brown-Twiss (HBT) radii are consistent with the corresponding results at similar root s(NN) from fixed-target experiments. Directed flow measurements are presented for both midrapidity and forward-rapidity regions. Furthermore the collision centrality dependence of identified particle dN/dy, < p(T)>, and particle ratios are discussed. These results also demonstrate that the capabilities of the STAR detector, although optimized for root s(NN) = 200 GeV, are suitable for the proposed QCD critical-point search and exploration of the QCD phase diagram at RHIC.
Resumo:
Superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is an all-superconducting-magnet electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged ion beams to meet the requirements of the Heavy Ion Research Facility in Lanzhou (HIRFL). To further enhance the performance of SECRAL, an aluminum chamber has been installed inside a 1.5 mm thick Ta liner used for the reduction of x-ray irradiation at the high voltage insulator. With double-frequency (18+14.5 GHz) heating and at maximum total microwave power of 2.0 kW, SECRAL has successfully produced quite a few very highly charged Xe ion beams, such as 10 e mu A of Xe37+, 1 e mu A of Xe43+, and 0.16 e mu A of Ne-like Xe44+. To further explore the capability of the SECRAL in the production of highly charged heavy metal ion beams, a first test run on bismuth has been carried out recently. The main goal is to produce an intense Bi31+ beam for HIRFL accelerator and to have a feel how well the SECRAL can do in the production of very highly charged Bi beams. During the test, though at microwave power less than 3 kW, more than 150 e mu A of Bi31+, 22 e mu A of Bi41+, and 1.5 e mu A of Bi50+ have been produced. All of these results have again demonstrated the great capability of the SECRAL source. This article will present the detailed results and brief discussions to the production of highly charged ion beams with SECRAL.
Resumo:
Some superconducting magnets research at IMP (Institute of Modern Physics, CAS, Lanzhou) will be described in this paper. Firstly, a superconducting electron cyclotron resonance ion source (SECRAL) was successfully built to produce intense beams of highly charged heavy ions for Heavy Ion Research Facility in Lanzhou (HIRFL). An innovation design of SECRAL is that the three axial solenoid coils are located inside of a sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. Some excellent results of ion beam intensity have been produced and SECRAL has been put into operation to provide highly charged ion beams for HIRFL since May 2007. Secondly, a super-ferric dipole prototype of FAIR Super-FRS is being built by FCG (FAIR China Group) in cooperation with GSI. Its superconducting coils and cryostat is made and tested in the Institute of Plasma Physics (IPP, Hefei), and it more 50 tons laminated yoke was made in IMP. This super-ferric dipole static magnetic field was measured in IMP, it reach to the design requirement, ramping field and other tests will be done in the future. Thirdly, a 3 T superconducting homogenous magnetic field solenoid with a 70 mm warm bore has been developed to calibrate Hall sensor, some testing results is reported. And a penning trap system called LPT (Lanzhou Penning Trap) is now being developed for precise mass measurements.
Resumo:
TiZrV合金吸气剂材料能够对气体分子进行化学吸附,并且最低激活温度Ta只有180℃,可以广泛地应用在各种设备中,例如粒子加速器,惰性气体净化装置,H2等离子体净化装置,托克马克中的H2回收装置。本论文通过计算设计,建立了二极直流磁控溅射系统,在国内首次对加速器细长真空管道进行了TiZrV膜层溅射沉积,使其成为管道泵。测试结果表明真空单元在TiZrVNEG处理后极限压力降低,同时压力分布梯度过大的问题得以解决;在镀膜系统的结构设计中创造性地加入了可压缩波纹管,解决了细长管道镀膜中阴极下垂引起短路及溅射距离不等的难题,使阴极始终处于管道中心,保证了镀膜的均匀性。论文对沉积膜层从基体材料、基体的表面粗糙度、基体温度、膜层成分对激活温度和真空性能的影响等方面进行了研究。对于理想状态下的磁控溅射,不同的基体材料会导致不同的膜层形态,但是具有相同的晶体结构和激活温度。通过沉积在粗糙的铜基材来增大表面粗糙度,不能加速激活过程,但明显增大了抽速和表面吸附容量。将溅射沉积过程中的基体温度(Ts)升高到250℃可以在不改变晶体结构的同时增大膜层的表面粗糙度。对于获得理想的粘附系数和表面吸气容量来说,基体温度Ts=250℃。使用粗糙的基体材料并在镀膜时将基体温度Ts保持在250℃可以获得最大的表面吸气容量。最大的抽速获得通过加热膜层到250℃。温度进一步升高,抽速开始下降
Resumo:
The pro sectile-like fragments of ~(16)O + ~(64)Ni Reaction (Elab = 96 MeV) were measured by using ionization chamber telescopes. The countour plots of d~36/dndEdz in TKE-θ plane angular distribution integrating over different TKE window. The z-distribution and angular distributions of different fragments from He to O were obtained. The main mechanisms dominating in this reaction were discussed
Resumo:
In the experiment of nuclear reaction, it is important to measure the mass, charge, energy and emitted direction of particles. For multiparameter measurement, we must use a detector or a group of detectors which can give the time, energy, and position information. The Large Area position sensitive Ionization Chamber(LAIC) is one of the eight experiment terminals of HIRFL. It is built for researching nuclear reactions from low energy to intermediate energy. It is an excellent equipment for energy measurements and atomic number identification of emitted fragments in this energy region. It is also designed to give the time and position information of the emitted fragments by itself. Obviously, an IC can not supply a good timing signal. Moreover, the mechanical installation is different from the original design by some other reasons. In this case, it is not enough to obtain the correct direction information of the emitted fragments. To obtain good timing signals and the correct direction information, some modifications must be made. It is well known that a PPAC can give us excellent timing signals. It also can be easily built as a position sensitive detector. For this reason, a specially designed PPAC is installed in the entrance of the LAIC. For the different purposes, two types of PPACs were designed and tested. Both are OCTPSACs (OCTunit one dimension Position Sensitive Avalanche Counter). In this paper, both OCTPSACs will be introduced. Based on the requirements of the LAIC, the OCTPSACs consist of eight position sensitive PPACs. Each PPAC has an anode and a cathode. In both cases, the sizes are same. But different type of cathodes are used. In one type of OCTPSAC, its cathode is made of wire plane. It consists of gold-plated tungsten wires with the diameter of 20μm, spaced 0.5 mm apart from each other. The anode is a mylar foil which was evaporated by gold layer with the thickness of 50μg/cm~2 mounted on a printed plate in the shape of rectangle. the thickness of mylar foil is 1.5μm. The gap between anode and cathode is 3mm. The performance of the OCTPSAC has been tested by using a ~(252)Cf source in flowing isobutylene gas at the pressure of 3.4mb. The intrinsic time resolution of 289ps and position resolution of 2 mm have been obtained. In another type of OCTPSAC, the cathode is made of mylar foil, which is composed of gold strip by vacuume evaporation method with a special mask on the mylar foil. The thickness and the width of the gold strip is 50μg/cm~2 and 1.7mm. The strips are spaced 0.3 mm apart from each other. The anode is the same as the former type. We have obtained the time resolution of 296ps and position resolution of 2mm by using ~(241)Am-a source when the gas pressure is 6 mb and high voltage is 600V. The working gas is heptane
Resumo:
An on-line sample introduction technique in capillary gas chromatograph (CGC) for the analysis of high-pressure gas-liquid mixtures has been designed and evaluated. A sample loop of 0.05 muL and a washing solvent loop of 0.5 muL are mounted on a 10-port switching valve, which serves as the injection valve. A capillary resistor was connected to the vent of sample loop in order to maintain the pressure of the sample. Both the sample and the washing solvent are transferred into the split-injection port through a narrow bore fused silica capillary inserted into the injection liner through a septum. The volume of the liner is used both as the pressure-release damper and evaporation chamber of the sample. On-line analysis of both reactants and resultants in ethylene olimer reaction mixture at 5 MPa was carried out, which demonstrated the applicability of the technique. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The effect of acid rain SO42− deposition on peatland CH4 emissions was examined by manipulating SO42− inputs to a pristine raised peat bog in northern Scotland. Weekly pulses of dissolved Na2SO4 were applied to the bog over two years in doses of 25, 50, and 100 kg S ha−1 yr−1, reflecting the range of pollutant S deposition loads experienced in acid rain-impacted regions of the world. CH4 fluxes were measured at regular intervals using a static chamber/gas chromatographic flame ionization detector method. Total emissions of CH4 were reduced by between 21 and 42% relative to controls, although no significant differences were observed between treatments. Estimated total annual fluxes during the second year of the experiment were 16.6 g m−2 from the controls and (in order of increasing SO42− dose size) 10.7, 13.2, and 9.8 g m−2 from the three SO42− treatments, respectively. The relative extent of CH4 flux suppression varied with changes in both peat temperature and peat water table with the largest suppression during cool periods and episodes of falling water table. Our findings suggest that low doses of SO42− at deposition rates commonly experienced in areas impacted by acid rain, may significantly affect CH4 emissions from wetlands in affected areas. We propose that SO42− from acid rain can stimulate sulfate-reducing bacteria into a population capable of outcompeting methanogens for substrates. We further propose that this microbially mediated interaction may have a significant current and future effect on the contribution of northern peatlands to the global methane budget.
Resumo:
Using static chamber technique,fluxes of CO2,CH4 and N2O were measured in the alpine grassland area from July 2000 to July 2001,determinations of mean fluxes showed that CO2 and N2O were generally released from the soil,while the alpine grassland accounted for a weak CH4 sink.Fluxes of CO2,CH4 and N2O ranged widely.The highest CO2 emission occurred in August,whereas almost 90?of the whole year emission occurred in the growing season.But the variations of CH4 and N2O fluxes did not show any clear patterns over the one-year-experiment.During a daily variation,the maximum CO2 emission occurred at 16:00,and then decreased to the minimum emission in the early morning.Daily pattern analyses indicated that the variation in CO2 fluxes was positively related to air temperatures(R^2=0.73)and soil temperatures at a depth of 5 cm(R^2=0.86),whereas daily variations in CH4 and N2O fluxes were poorly explained by soil temperatures and climatic variables.CO2 emissions in this area were much lower than other grasslands in plain areas.
Resumo:
用压力室连续测定了玉米根系升压和降压过程的导水率。结果表明 ,降压过程测得的根系导水率显著大于用升压过程的 ,并且前者的相关系数大于后者。这种差异是由于这两个过程中质外体途径细胞壁空间充水量不同造成的。开始升压时 ,由于细胞壁空间含水量低 ,质外体途径阻力大 ,导致非结构阻力 ;随着压力的升高 ,细胞壁空间含水量增大 ,质外体途径导度增大 ,减小甚至可以消除非结构阻力。降压法可以使根系快速复水 ,消除传统方法因长时间复水所致根结构的改变。建议用降压法测定根系导水率
Resumo:
National Key Research and Development Program [2010CB833500]; National Natural Science Foundation of China [30590381]; Chinese Academy of Sciences [KZCX2-YW-432]
Resumo:
This paper presents results of 2 years (from January 2005 to December 2006) of measurement of N2O fluxes from the native and grazed Leymus chinensis (LC) steppes in Inner Mongolia, China using the static opaque chamber method. The measurement was at a frequency of twice per month in the growing season and once per month in the non-growing season. In addition, the possible effect of water-heat factors on N2O fluxes was statistically analyzed. The results indicated that there were distinct seasonal patterns in N2O fluxes with large fluxes in spring, summer, and autumn but negative fluxes in winter. The annual net emission of N2O ranging from 0.24 to 0.30 kg N2O-N ha(-1) and from 0.06 to 0.26 kg N2O-N ha(-1) from the native and grazed LC steppe, respectively. Grazing activities suppressed N2O production. In the growing season, soil moisture was the primary driving factor of N2O fluxes. The high seasonal variation of N2O fluxes was regulated by the distribution of effective rainfall, rather than precipitation intensity. Air temperature or soil temperature at 0, 5, and 10 cm depth was the most restricting factor of N2O fluxes in the non-growing season.