110 resultados para copper(II) and cobalt(II) complexes
Resumo:
Equilibrium distributions of cobalt(II), nickel(II), zinc(II), cadmium(II), and copper(II) have been studied in the adsorption with extraction resin containing 1-hexyl-4-ethyloctyl isopropylphosphonic acid (HEOPPA) as an extractant from chloride medium. The distribution coefficients are determined as a function of pH. The data are analyzed both graphically and numerically. The extraction of the metal ions can be explained assuming the formation of metal complexes in the resin phase with a general composition ML2(HL)(q). The adsorbed species of the metal ions are proposed to be ML2 and the equilibrium constants are calculated. The efficiency of the resin in the separation of the metal ions is provided according to the separation factors values. The separation of Zn from Ni, Cd, Cu, Co, and Co from Ni, Cd, Cu with the resin is determined to be available. Furthermore, Freundlich's isothermal adsorption equations and thermodynamic quantities, i.e., DeltaG, DeltaH, and DeltaS are determined.
Resumo:
A novel approach of generating cathodic electrochemiluminescence lof Ru(bpy)(3)(2+) at -0.4 V triggered by reactive oxygen species is reported for detecting alkylamines and some organic acids.
Resumo:
Four novel screw-like Ru(II) complexes, tris(5-lauramide-1,10-phenanthroline)Ru(II) bishexafluorophosphate, tris(5-myristamide-1,10-phenanthroline)Ru(II) bishexafluorophosphate, tris(5-palmitamide-1,10-phenanthroline)Ru(II) bishexafluorophosphate and tris (5-stearamide-1,10-phenanthroline)Ru(II) bishexafluorophosphate have been efficiently synthesized. They are confirmed by the techniques of IR, H-1 NMR, H-1-H-1 COSY and ES-MS. Also, their electrochemistry, fluorescence and electrochemiluminescence are reported.
Resumo:
Measurement of iron and manganese is very important in evaluating the quality of natural waters. We have constructed an automated Fe(II), total dissolved iron(TDI), Mn(II), and total dissolved manganese(TDM) analysis system for the quality control of underground drinking water by reverse flow injection analysis and chemiluminescence detection(rFIA-CL), The method is based on the measurement of the metal-catalyzed light emission from luminol oxidation by potassium periodate. The typical signal is a narrow peak, in which the height is proportional to light emitted and hence to the concentration of metal ions. The detection limits were 3 x 10(-6) mu g ml(-1) for Fe(II) and the linear range extents up to 1.0 x 10(-4) and 5 x 10(-6) mu g ml(-1) for Mn(II) cover a linear range to 1.0 x 10(-4) mu g ml(-1). This method was used for automated in-situ monitoring of total dissolved iron and total dissolved in underground water during water treatment. (C) 1997 Elsevier Science B.V.
Resumo:
The behaviour of the electroplated copper film electrode on tin oxide/glass or glassy carbon surface was studied in potassium hydroxide medium by cyclic voltammetry and in situ transmission spectroelectrochemistry. The results indicate that the electroplated copper film electrode is similar to a copper electrode and cyclic voltammetry with this electrode affords more resolution. The anodic peaks were found to correspond successively to the adsorption of oxygen, the formation of a surface layer of Cu2O, the formation of a surface layer of Cu(OH)2 or CuO and formation of a thick multilayer film of CuO. This is the first time it has been proposed that a surface layer of Cu(OH)2 or CuO is formed from the oxidation of the surface layer of Cu2O. Similarly, a clear interpretation is presented that the cathodic peaks correspond successively to the reduction of CuO to Cu2O, the reductions of Cu2O to Cu and the soluble Cu(II) species to Cu. On the other hand, a shoulder peak related to the chemical transformation of Cu(OH)2 to CuO was first observed.