244 resultados para Types of tires by ply.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The selective catalytic reduction of NO by CH4 was compared over In-Fe2O3/HZSM-5 catalysts prepared by impregnation and co-impregnation methods. It was found that the catalyst preparation method greatly affected the catalyst activity. The impregnated catalyst was very active, but the co-impregnated one showed poor activity. The In Fe2O3/HZSM-5 catalysts were investigated by Mossbauer spectroscopy. The results showed that indium cations entered into the iron oxide lattice in the co-impregnated catalyst, while the impregnated catalyst exhibited a more stable structure, when both of the catalysts were treated severely in the reaction atmosphere. Characterization by means of combined in situ temperature programmed reduction (TPR)- Mossbauer spectroscopy further revealed that the performances of the two catalysts were different in the TPR processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A cellulose trisphenylcarbamate-bonded chiral stationary phase was applied to nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC) with nonaqueous and aqueous solutions as the mobile phases. Several chiral compounds were successfully resolved on the prepared phase by nano-LC. The applicability of nonaqueous CEC on a cellulose derivative stationary phase was investigated with the organic solvents methanol, hexane, 2-propanol, and tetrahydrofuran (THF) containing acetic acid, as well as triethylamine as the mobile phases. Enantiomers of warfarin and praziquantel were baseline-resolved with plate numbers of 82 300 and 38 800 plates/m, respectively, for the first eluting enantiomer. The influence of applied voltage, concentration of nonpolar solvent, apparent pH, and buffer concentration in the mobile phase on the electroosmotic flow (EOF) and the mobility of the enantiomers was evaluated. Enantioseparations of traps-stilbene oxide and praziquantel were also achieved in aqueous CEC with plate numbers of 111 100 and 107 400 plates/m, respectively, for the first eluting enantiomer. A comparison between nonaqueous CEC and aqueous CEC based on a cellulose trisphenylcarbamate stationary phase was discussed. Pressure-assisted CEC was examined for the chiral separation of praziquantel and faster analysis with high enantioselectivity was acquired with the proper pressurization of the inlet vial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peptide mass mapping analysis, utilizing a regenerable enzyme microreactor with metal-ion chelated adsorption of enzyme, combined with matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) was developed. Different procedures from the conventional approaches were adopted to immobilize the chelator onto the silica supports, that is, the metal chelating agent of iminodiacetic acid (IDA) was reacted with glycidoxypropyltrimethoxysilane (GLYMO) before its immobilization onto the inner wall of the fused-silica capillary pretreated with NH4HF2. The metal ion of copper and subsequently enzyme was specifically adsorbed onto the surface to form the immobilized enzyme capillary microreactor, which was combined with MALDI-TOF-MS to apply for the mass mapping analysis of nL amounts of protein samples. The results revealed that the peptide mapping could routinely be generated from 0.5 pmol protein sample in 15 min at 50degreesC, even 20 fmol cytochrome c could be well digested and detected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pressurized electrochromatography (pCEC) instrument with gradient capability was used in this work for separation of peptides. Three separation modes, namely, pCEC, high-performance liquid chromatography and capillary electrophoresis can be carried out with the instrument. In pCEC mode, the mobile phase is driven by both electroosmotic flow and pressurized flow, facilitating fine-tuning in selectivity of neutral and charged species. A continuous gradient elution can be carried out conveniently on this instrument, which demonstrates that it is more powerful than isocratic pCEC for separation of complicated samples. The effects of applied voltage, supplementary pressure and ion-pairing agents on separation of peptides in gradient pCEC were investigated. The effects of flow-rate of the pump and the volume of the mixer on resolution were also evaluated. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-throughput screening is a promising new approach in analytical chemistry. Within the framework of an extended screening program (The German-Chinese Drug Screening Program), the enantioseparation of 86 drugs was investigated by capillary zone electrophoresis in the presence of the chiral solvating agent (CSA) octakis-(2,3,6-tri-O-methyl)-gamma-cyclodextrin (TM-gamma-CD). By this means, 15 drugs could be separated into enantiomeric pairs. Approximate measures for the degree of interaction (migration retardation factor, R-m) and for the degree of enantiomer recognition (migration separation factors, alpha(m)) revealed intriguing patterns that were compared with those found for native gamma-cyclodextrin (gamma-CD). Although there is a distinct influence of the analyte structure on the electrophoretic data, interpretation remains difficult. Most remarkably, permethylation of gamma-CD leads neither to a higher affinity nor to better chiral recognition, in contrast to the findings with alpha-CD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Catalytic decomposition of NO was studied over Fe/NaZSM-5 catalyst. Novel results were observed with the microwave heating mode. The conversion of NO to N-2 increased remarkably with the increasing of Fe loading. The effects of a series of reaction parameters, including reaction temperature, O-2 concentration, NO concentration, gas flow rate and H2O addition, on the productivity of N-2 have been investigated. It is shown that the catalyst exhibited good endurance to excess O-2 in the microwave heating mode. Under all reaction conditions, NO converted predominantly to N-2. The highest conversion of NO to N-2 was up to 70%. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Asia 3 Foresight Program [30721140307]; National Key Research and Development Program [2010CB833500]; National Natural Science Foundation of China [30590381, 30900198];

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Funding and support for this project was provided by NSFC (Grant No. 40771015), and Key International Science and Technology Cooperation Projects (Grant No. 22007DFC20180). The authors also gratefully acknowledge the support of Key Projects in the National Science & Technology Pillar Program in the Eleventh Five-year Plan Period (Grant No. 2006BAD01B06-02). The authors thank the CDCs of Daqing, Beijing, Tianjin, Zhengzhou, Changsha and Shenzhen cities for field and laboratory technical support.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the first time, we report a sensitive and selective method to detect Cu2+ based on the electrochemiluminescence quenching of CdTe quantum dots (QDs) in aqueous solution. The mercaptosuccinic acid (MSA) protected CdTe QDs were prepared and characterized with UV, fluorescence and ECL. The anodic ECL quenching mechanism was attributed to the fact that MSA capping was removed from the surface of the CdTe QDs and preferentially bound with Cu2+. The displacement of MSA capping layer created imperfections on the CdTe QDs surface, and eventually led to the ECL quenching.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple light scattering detection method for neurotransmitters has been developed, based on the growth of gold nanoparticles. Neurotransmitters (dopamine, L-dopa, noradrenaline and adrenaline) can effectively function as active reducing agents for generating gold nanoparticles, which result in enhanced light scattering signals. The strong light scattering of gold nanoparticles then allows the quantitative detection of the neurotransmitters simply by using a common spectrofluorometer.