110 resultados para Nonhomogeneoulsy loaded waveguides
Resumo:
The mechanism of fatigue crack nucleation for nanocrystalline (nc) nickel was experimentally investigated in this paper. The samples of electrodeposited ne nickel were loaded cyclically by using a three point bending instrument at first. Then, atomic force microscopy (AFM) was used to scanning the sample surface after fatigue testing. The results indicated that, after fatigue testing, there are vortex-like cells with an average size of 108nm appeared along the crack on nc nickel sample. And, the roughness of sample surface increased with the maximum stress at the surface.
Resumo:
基于炸药的热爆炸理论,采用炸药的热点温度(也称为临界起爆温度)作为起爆判据,分析了装药弹体在侵彻混凝土厚靶过程中的炸药安全性问题,建立了炸药摩擦起爆的热传导模型.对模型进行了量纲一化分析,得出量纲一热流率幅值Qm与炸药和弹壳界面量纲一温度峰值T′max的关系,以及可在实际工程中应用的临界量纲一控制参数Qmc,同时得到了反映摩擦产生的热量在炸药与弹壳间分配比例关系的量纲一参数ΚⅠ.结果表明,炸药装药和弹壳接触面间的强摩擦是形成热点、从而导致炸药早炸的一个重要因素.
Resumo:
It is the first time in China that the phase variations and phase shift of microwave cavity in a miniature Rb fountain frequency standard are studied, considering the effect of imperfect metallic walls. Wall losses in the microwave cavity lead to small traveling wave components that deliver power from the cavity feed to the walls of cavity. The small traveling wave components produce a microradian distribution of phase throughout the cavity ity, and therefore distributed cavity phase shifts need to be considered. The microwave cavity is a TE011 circular cylinder copper cavity, with round cut-hole of end plates (14mm in diameter) for access for the atomic flux and two small apertures in the center of the side wall for coupling in microwave power. After attenuation alpha is calculated, field variations in cavity are solved. The field variations of the cavity are given. At the same time, the influences of loaded quality factor QL and diameter/height (2a/d) of the microwave cavity on the phase variations and phase shift are considered. According to the phase variation and phase shift of microwave cavity we select the parameters of cavity, diameter 2a = 69.2mm, height d = 34.6mm, QL = 5000, which will result in an uncertainty delta(Delta f / f0 ) < 4.7 x 10(-17) and meets the requirement for the miniature Rb fountain frequency standard with accuracy 10(-15).
Resumo:
建立了一套用于玻色.爱因斯坦凝聚实验的铷原子双磁光阱装置.从低速强源中获得慢原子柬,向超高真空磁光阱进行原子转移.低速强源磁光阱与超高真空磁光阱之间可维持3个量级的压强差,超高真空磁光阱的真空度最高可达1×10^-9Pa.慢原子束的束流通量达1×10^9/s.约4×10^8个^17Rb原子被装载到超高真空磁光阱中.还讨论了两种典型情况下磁光阱中装载的最大原子数.
Resumo:
We demonstrate the guiding of neutral atoms with two parallel microfabricated current-carrying wires on the atom chip and a vertical magnetic bias field. The atoms are guided along a magnetic field minimum parallel to the current-carrying wires and confined in the other two directions. We describe in detail how the precooled atoms are efficiently loaded into the two-wire guide. We present a detailed experimental study of the motional properties of the atoms in the guide and the relationship between the location of the guide and the vertical bias field. This two-wire guide with vertical bias field can be used to realize large area atom interferometer.