95 resultados para iron (0)
Resumo:
Rate of hydrogen permeation was measured under static as well as dynamic mechanical deformation conditions, Cylindrical tensile test specimens were used for the study and hydrogen permeation was measured electrochemically, It was observed that the hydrogen diffusivity decreased as plastic deformation increased for the static deformation experiments while elastic deformation had no significant effect on diffusivity but increased the steady state permeation flux, For the dynamic loading experiment, an elastic deformation increased the hydrogen permeation rate almost linearly. Onset of plastic deformation led a sudden decrease of permeation rate and the reduced rate was rapidly recovered when the plastic deformation ceased. These rapid changes in the permeation rates were explained that the absorbed hydrogen was trapped by dislocations and creation rate and density of dislocations changed drastically when plastic deformation started and stopped.
Resumo:
The chloride extraction rule of iron artifacts was studied by electrical methods. The effect of the current and potential value on the desalination result of simulated iron artifacts was studied through the galvanostatic and potentiostatic experiments the ingredients of the rust before and after treatments were also analyzed by the X-ray diffraction (XRD). It has been found that the optimal current density was between -0.50 and -0.75 mA/cm(2) and the optimal potential was between -1.175 and -1.200 V. The phase of the samples rusts transformed after treatment, as well as the anti-corrosion performance improved.
Resumo:
By first principle methods based on density functional theory (DFT),the equation of state(EOS) and elastic constants of both periclase and ferropericlase are calculated. The pressure and iron doping effects on the elastic constants of ferropericlase are investigated systematically. Firstly, we calculate the elastic constants of periclase and compare the obtained results with experimental data and other theoretical calculations, which shows a encouraging consistence and demonstrates the practicability of first-principle methods. Secondly, by adding iron into periclase crystal model, we build up ferropericlase with iron contents ranging from 0% to 25% mole percent. The corresponding elastic constants are calculated in a large pressure range(0~120GPa). Emphatically, the strong correlation of 3d electrons in transitional elements, such as iron, is difficult to treat in first-principle methods for a long time. The current solution is to make additional correction. During the initial stage of this study, the strong correlation of 3d electrons in iron is not considered, and we observed that addition of iron decreases the volume of ferropericlase, which is totally contradictory to the experimental data. By applying LDA+U approximation in order to solve the strongly correlated 3d electron of iron, we observed the expansion of volume by iron as expected. On the basis of the LDA+U approximation, the elastic constants of ferropericlase are calculated. After a detailed analysis of data obtained from theoretical calculations, we have reached the following conclusions:(1)pressure imposes positive effects on all elastic constants, and the degree of effects is C11>C12>C44. (2) Iron has no distinctive effects on C11 and C12, although some fluctuations are observed around 60GPa. However, iron has obvious softening effects on C44 The softening effects on C44 are intensified as pressure increases. Above the 100GPa, the effects increase greatly, even surpasses the pressure's positive effects in ferropericlase crystal models with iron mole percent of having 12.5%, 18.75% and 25% iron content. (3)As to the modulus deprived from elastic constants, iron has no effect on the adiabatic bulk module BS, only a little fluctuation around 60GPa. We find iron's softening effects on shear modulus G. (4)We find out that, compared with low iron content, elastic constants with iron content approaching 25mole% is consistently fluctuated,which may be caused by the limitations of the LDA+U approximation method itself. (5)We investigate the pressure and Fe doping effects on elastic anisotropy factor(A=(2C44+C12-C11)/C11) of ferropericlase and find out that iron contents will lower the critical isotropic pressure. At the same pressure, when the pressure is below the isotropic pressure, iron softens the anisotropy factor ; when pressure surpasses the isotropic pressure, iron increases the anisotropy factor.
Resumo:
The reduction behaviors of the supported platinum-iron catalysts and their comparison with supported iron catalysts were studied by TPR (temperature-programmed reduction)-in situ Fe-57 MBS (Mossbauer spectroscopy). The results indicated that the TPR processes of all Fe-containing catalysts were different from that of bulk alpha-Fe2O3. There were interactions between Pt, Fe and the gamma-Al2O3 or SiO2 support for the Pt-Fe/gamma-Al2O3 and Pt-Fe/SiO2 catalysts. All the iron-containing catalysts show that Fe3+ was highly dispersed on the support (gamma-Al2O3 and SiO2) before reduction. No Fe-0 was found in the reduction processes. The Fe3+ was reduced to Fe2+ in tetrahedral vacancy first for the reduction of the Pt-Fe/gamma-Al2O3 catalyst. No Fe2+ in octahedral vacancy was found in the reduction of the Pt-Fe/SiO2 catalyst. Adding Pt to Fe/support (gamma-Al2O3 or SiO2) could promote the reduction of the Fe species. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
A capillary electrophoresis (CE) technique for determining total iron binding capacity (TIBC) of serum has been developed. The optimum serum pretreatment involves the following major steps: at first, saturate serum transferrin with Fe+3; then, dissociate them completely after removing excess unbound Fe. Finally, complex the released iron with phenanthroline, a chromophore, to make suitable for the CE analysis. Ammonium acetate (pH = 5.0) was used as CE background electrolyte solution. In this system, a good linear correlation coefficient was maintained over the range 0.5 similar to 10 mu M (r = 0.9979, n =12). Seven adult serum samples were studied and the TIBC parameters measured. In the present system, 10 similar to 30 mu L serum is sufficient for determination. The study shows that the CE technique described is a powerful method for rapid, efficient, sensitive and reliable analysis and hence particularly suitable for clinical application.