260 resultados para indium compounds
Resumo:
This paper reports an analytical method for separating, identifying, and quantifying sulfur-containing compounds in crude oil fraction (IBP-360degreesC) samples based on comprehensive two-dimensional gas chromatography coupled with a sulfur chemiluminescence detector. Various sulfur-containing compounds and their groups were analyzed with one direct injection. 3620 peaks were detected including 1722 thiols/thioethers/ disulfides/1-ring thiophenes, 953 benzothiophenes, 704 dibenzothiophenes, and 241 benzonaphthothiophenes. The target sulfur compounds and their groups were identified based on the group separation feature and structured retention of comprehensive two-dimensional gas chromatography as well as standard substances. The quantitative analysis of major sulfur-containing compounds and total sulfur was based on the linear response of the sulfur chemiluminescence detector using the internal standard method. The sulfur contents of target sulfur compounds and their groups in 4 crude oil fractions were also determined. The recoveries for standard sulfur-containing compounds were in the range of 90-102%. The quantitative result of total sulfur in the Oman crude oil fraction sample was compared with those from ASTM D 4294 standard method (total S by X-ray fluorescence spectrometry), the relative deviation (RD%) was 4.2% and the precision of the method satisfactory.
Resumo:
Reversed-phase high performance liquid chromatography (RP-HPLC) was employed to develop predictive models for fish bioconcentration factors (BCF) of organic compounds. Estimation of BCF from RP-HPLC retention parameters on octadecyl-bonded silica gel (ODS), cyanopropyl-bonded silica gel (CN), and phenyl-bonded silica gel (Ph) columns were investigated. The results show that, for a set of compounds belonging to different chemical classes, the CN stationary phase is the best one among the three columns and better than n-octanol/water model for BCF estimation. A multi-column RP-HPLC model, using the retention parameters on the CN and Ph columns as the variables of multiple linear regression equations, was further evaluated to estimate BCF of organic compounds belonging to different chemical classes, and the results show that the multi-column RP-HPLC model is better than that of any single RP-HPLC column for BCF estimation.
Resumo:
Methacrylate-based monolithic columns with electroosmotic flow (EOF) or very weak EOF are prepared by in situ copolymerization in the presence of a porogen in fused-silica capillaries pretreated with a bifunctional reagent. Satisfactory separations of acidic and basic compounds on the column with EOF at either low or high pH are achieved, respectively. With sulfonic groups as dissociation functionalities, sufficient EOF mobility still remains as high as 1.74 x 10(-4) cm(2) s(-1) V-1 at low pH. Under this condition, seven acidic compounds are readily separated within 5.7 min. Moreover, at high pH, the peak shape of basic compounds is satisfactory without addition of any masking amines into running mobile phase since the secondary interaction between the basic compounds and the monolithic stationary phase are minimized at high pH. Reversed-phase mechanism for both acidic and basic compounds is observed under investigated separation conditions. In addition, possibilities of acidic and basic compound separations on a monolithic column with extremely low EOF are discussed. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
A comprehensive two-dimensional liquid chromatographic separation system based on the combination of a CN column and an ODS column is developed for the separation of components in a traditional Chinese medicine (TCM) Rhizoma chuanxiong. Two columns are coupled by a two-position, eight-port valve equipped with two storage loops and controlled by a computer. The effluent is detected by both the diode array detector and atmospheric pressure chemical ionization (APCI) mass spectrometer. More than 52 components in the methanol extract of R. chuanxiong were resolved and 11 of them were preliminary identified according to their UV and mass spectra. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Traditional Chinese medicines (TCMs), due to their long time clinic test and reliable therapeutic efficacy, are attracting increased global attention served as excellent pools of bioactive compounds for the discovery of new drugs. However, hundreds or even thousands of components are usually contained in traditional Chinese medicines and only a few compounds are responsible for the pharmaceutical and/or toxic effects. The large numbers of other components in traditional Chinese medicines make the screening and analysis of the bioactive components extremely difficult. By the way, the combination effect of bioactive components on the pharmacological activity makes it very difficult to clear the therapeutic mechanism of TCMs. Therefore, some strategies have to design for screening of bioactive compounds in traditional Chinese medicines, which further leads to disclose the therapeutic mechanism of TCMs in molecular level. The review will summarize the present state of the art of screening strategy for active compounds in traditional Chinese medicines, and the chromatography methods for screening and analysis of bioactive compounds in traditional Chinese medicines will be emphasized. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
A polymer-based monolithic capillary column imprinted with 4-aminopyridine (4-AP) was prepared by a thermally-initiated polymerization process; and its performance as a capillary electrochromatographic medium was evaluated in separating 4-AP and 2-AP isomers. The effects of experimental parameters, such as pH value and ionic strength of the buffer, the acetonitrile content in the mobile phase, and the applied voltage, on the resolution of these isomers had been carefully investigated. It was found that in the retention process there were interplays of multiple mechanisms of ion-exchange, molecular imprinting, and electrophoresis. These mechanisms allowed more sophisticated control of experimental parameters in the separation of ionizable compounds.
Resumo:
This article reports an analytical method for separating, identifying and quantitating sulfur-containing compounds and their groups in diesel oils (170-400degreesC) using comprehensive two-dimensional gas chromatography coupled with a sulfur chemiluminescence detector. The identification of target compounds and their groups was based on standard substances, the group separation feature and the-effect of comprehensive two-dimensional gas chromatography. The quantitative analysis on major sulfur compounds and total sulfur was carried out based on the linear response of sulfur chemiluminescence detector and the internal standards method. The results of total sulfur determination in the samples were compared with those from ASTM D 4294 standard method, the R.S.D. percentage were <6.02%, correctness of this method can meet the industrial requirement. To the end, the method developed was used to investigate the sulfur-containing compounds in different diesel oils, the result shows that the distribution of sulfur-containing compounds in diesel oils from different process units are apparently different. The sulfur compounds in fluid catalytic cracking (FCC), residuum fluid catalytic cracking (RFCC) diesel oils mainly exist in the form of alkyl-substituted dibenzothiophenes that add up to about 40-50% of the total sulfur, while this number is only 6-8 and 20-28% in visbreaking (VB) and delayed-coking (DC) diesel oils, respectively. (C) 2003 Elsevier B.V. All rights reserved.