142 resultados para PHOSPHATIDYLCHOLINE CHOLESTEROL MEMBRANES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The voltammetric behaviour of dye-modified supported bilayer lipid membranes is investigated. (C) 1997 Elsevier Science S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the TCNQ-modified BLM, the voltammetric response is different due to the different methods used to prepare the membrane forming solution. The direct and indirect dissolved methods result in irreversible and reversible responses respectively. These results can be explained by the different styles of the orientation of TCNQ in the membrane. The reversible response is controlled by the diffusion of electroactive species in the interior of the membrane. When MB is used to modify the BLM, very complex voltammograms are obtained. The intersection of the voltammetric curves can be regarded to be owing to the appearance of new phase in the membrane caused by MB. But it disappears at lower scan rate. Peak current increases with decreasing scan rate. This indicates that the resistance of the membrane at lower scan rate is lower than that at higher scan rate. Asymmetric curve of MB incorporated BLM is ascribed to the different rates of redox reaction at the two membrane/solution interfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monolayers of biological compounds including redox proteins and enzymes, and phospholipids have been immobilized on a gold electrode surface through self-assembling. These proteins and enzymes, such as cytochrome c, cytochrome c oxidase and horseradish peroxidase (HRP), immobilized covalently to the self-assembled monolayers (SAMs) of 3-mercaptopropionic acid on a gold electrode, communicate directly electrons with the electrode surface without mediators and keep their physiological activities. The electron transfer of HRP with the gold electrode can also be mediated by the alkanethiol SAMs with electroactive group viologens on the gold electrode surface. All these direct electrochemistries of proteins and enzymes might offer an opportunity to build a third generation of biosensors without mediators for analytes, such as H2O2, glucose and cholesterol. Monensin and valinomycin have been incorporated into the bilayers on the gold electrode consisting of the SAMs of alkanethiol and a lipid monolayer, which have high selectivity for monovalent ions, and the resulting Na+ or K+ sensor has a wide linear range and high stability. These self-assembly systems provide a good mimetic model for studying the physiological function of a membrane and its associated enzyme. (C) 1997 Elsevier Science S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction of La3+ and cholesterol with the negatively charged phospholipid dipalmitoylphosphatidylglycerol bilayers was studied by Fourier transform-Raman spectroscopy. La3+ was shown to increase interchain order and intermolecular ordering of the lipid lattice, cholesterol exhibited less of an effect, the La3+-DPPG-cholesterol complex was more ordered than cholesterol=DPPG nd less ordered than La3+-DPPG complexes, cholesterol modulates the order/disorder parameters of DPPG bilayers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supported lipid membranes consisting of self-assembled alkanethiol and lipid monolayers on gold substrates could be produced by three different deposition methods: the Langmuir-Blodgett (L-B) technique, the painted method, and the paint-freeze method, By using cyclic voltammetry, chronoamperometry/chronocoulometry and a.c. impedance measurements, we demonstrated that lipid membranes prepared by these three deposition methods had obvious differences in specific capacitance, resistance and thickness. The specific capacitance of lipid membranes prepared by depositing an L-B monolayer on the alkanethiol alkylated surfaces was 0.53 mu Fcm(-2), 0.44 mu Fcm(-2) by the painted method and 0.68 mu Fcm(-2) by the paint-freeze method. The specific conductivity of lipid membranes prepared by the L-B method was over three times lower than that of the painted lipid membranes, while that of the paint-freeze method was the lowest. The difference among the three types of lipid membranes was ascribed to the influence of the organic solvent in lipid films and the changes in density of the films. The lipid membranes prepared by the usual painted method contained a trace amount of the organic solvent. The organic solvent existing in the hydrocarbon core of the membrane reduced the density of the membrane and increased the thickness of the membrane. The membrane prepared by depositing an L-B monolayer containing no solvent had higher density and the lowest fluidity, and the thickness of the membrane was smaller. The lipid membrane prepared by the paint-freeze method changed its structure sharply at the lower temperature. The organic solvent was frozen out of the membrane while the density of the membrane increased greatly. All these caused the membrane to exist in a ''tilted'' state and the thickness of this membrane was the smallest. The lipid membrane produced by the paint-freeze method was a membrane not containing organic solvent. This method was easier in manipulation and had better reproducibility than that of the usual painting method and the method of forming free-standing lipid film. The solvent-free membrane had a long lifetime and a higher mechanical stability. This model membrane would be useful in many areas of scientific research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cyclic voltammetry was employed to study the influence of sterols on the lipophilic ion transport through the BLM. The mole fraction of the sterols (cholesterol, oxidized cholesterol). as referred to total lipid, was varied in a range of 0-0.8. Data demonstrate that a thin-layer model is suitable to this BLM system. By this model, the number of charges transported per lipophilic ion, the concentration of the ion in the membrane bulk phase and the aqueous/membrane phase partition coefficient could be calculated. These parameters proved that sterols had an obvious influence on the lipophilic ion transport. Cholesterol had a stronger influence on the ion transport than oxidized cholesterol. Its incorporation into egg lecithin membranes increased the partition coefficient beta of the ion up to more than 3-fold. Yet, oxidized cholesterol incorporated into egg lecithin membranes only increased the beta up to less than 2-fold, and the beta had no great variation at different oxidized cholesterol mole fractions. The higher beta obtained was partly due to the trace amount of solvent existing in the core of the lipid bilayers. At the different sterol mole fractions, combining the change of beta with the change of peak current, we also concluded that sterols had somewhat inhibiting effect on the ion transport at the higher sterols mole fraction (>0.4). These results are explained in terms of the possible change of dipole potential of the membrane produced by sterols and the decrease of the membrane fluidity caused by the condensation effect of sterols and the thinning effect caused by sterols. The substituting group (in the oxidized cholesterol) had some inhibiting effects on the ion transport at higher mole fractions (oxidized cholesterol mole fraction >0.4).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of lanthanum and calcium on the structure and function of human erythrocyte membranes was investigated by fluorescence polarization, spin- labeled electron spin resonance (ESR) and laser Raman spectroscopy. The results showed that low concentration of La3+ (0.5 mu mol/L) activated a Little (Na++K+)-ATPase and Mg2+-ATPase activities, and it inhibited obvi ously the ATPase activities with increasing its concentrations. La3+ lowered the lipid fluidity of human erythrocyte membranes and decreased the vibration intensity of alpha-helix of the protein in the Amide I '. The effect of Ca2+ on the lipid fluidity and alpha-helix of the protein in the Amide I ' was smaller than that of La3+.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is found that there is a linear relationship between log P-w, and the parameter term V-f/0.5 E(coh) [1+(delta(w) - delta(p))(2)/delta(p)(2), from the water permeability (P-w) data of 21 polymers covering 4 orders of magnitude. This correlation may be useful in choosing membrane materials for dehumidification of gases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water vapor absorption and desorption by poly (phenylene oxide) (PPO) and sulfonated PPO (SPPO) membranes were studied at a constant temperature of 30-degrees-C and over a broad range of water activity (0.05 less-than-or-equal-to a < 0.8) by the weighing

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(2,6-dimethylphenylene oxide) (PPO) was sulfonated to varying degrees using different sulfonating agents. Physical properties such as solubility, density, and thermal properties were studied for both PPO and sulfonated PPO (SPPO) with different degree

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The permeation behaviors of water vapor and gases were studied for both PPO and SPPO of different sulfonation degree. It was found that the permeability of water vapor increased, and those of oxygen and nitrogen decreased; thus the selectivity for water v

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of lanthanide ions (Ln(3+)) and their coordination compounds of diethylenetriamine pentaacetic acid (DTPA) on the phase behavior of dipalmitoylphosphatidycholine (DPPC) multilamellar liposomes has been studied by differential scanning calorimet

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A layer of palladium particles was electrodeposited on a glassy carbon electrode. The dispersed Pd particles resulted in a large decrease in overvoltage for the electrochemical oxidation of H2O2 down to +0.4 V vs. Ag/AgCl, based on which a new kind of cholesterol sensor was fabricated. Cholesterol oxidase was immobilized on the Pd-dispersed electrode by cross-linking with glutaraldehyde and a layer of poly(o-phenylenediamine) (PPD) film was electropolymerized on the enzyme layer. The sensor shows a linear response in the concentration range 0.05-4.50 mmol l-1 with a rapid response of less than 20 s. The polymer film can prevent interference from uric acid and ascorbic acid and also increases the thermal stability of the sensor. The sensor can be used for 200 assays without an obvious decrease in activity.