231 resultados para PERFORMANCE LIQUID-CHROMATOGRAPHY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

4-Aminophenol (4-AP), paracetamol (PRCT), norepinephrine (NE), and dopamine (DA) (all somewhat hydrophobic compounds) were HPLC electrochemically detected while the signals from uric acid (UA) and ascorbic acid (AA) (both hydrophilic compounds at the pH studied) were minimized, taking advantage of the permselectivity of the self-assembled n-alkanethiol monolayer (C-10-SAM)-modified Au electrodes based on solute polarity, The effects of various factors, such as the chain length of the n-alkanethiol modifier, modifying time, and pH value, on the permeability of C-10-SAM coatings were examined, The calibration curves, linear response ranges, detection limits, and reproducibilities of the EC detector for 4-AP, PRCT, NE, and DA were obtained, The result shows that the EC detector can be applied in the chromatographic detection of 4-AP, PRCT, NE, and DA in urine, effectively removing the influence of UA and AA in high concentrations existing in biological samples. As a result, a great improvement in the selectivity of EC detectors has been achieved by using Au electrodes coated with neutral n-alkanethiol monolayer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An assay procedure utilizing pulsed amperometric detection at a platinum-particles modified electrode has been developed for the determination of cysteine and glutathione in blood samples following preliminary separation by reversed-phase liquid chromatography. A chemically modified electrode (CME) constructed by unique electroreduction from a platinum-salt solution to produce dispersed Pt particles on a glassy carbon surface was demonstrated to catalyze the electo-oxidation of sulfhydryl-containing compounds: DL-cysteine (CYS), reduced glutathione (GSH). When used as the sensing electrode in flow-system pulsed-amperometric detection (PAD), electrode fouling could be avoided using a waveform in which the cathodic reactivation process occurred at a potential of - 1.0 V vs. Ag/AgCl to achieve a cathodic desorption of atomic sulfur. A superior detection limit for these free thiols was obtained at a Pt particle-based GC electrode compared with other methods; this novel dispersed Pt particles CME exhibited high electrocatalytic stability and activity when it was employed as an electrochemical detector in FIA and HPLC for the determination of those organo-sulfur compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A wall-jet cell/carbon fibre microelectrode detector was designed and used for the micellar liquid chromatographic assay of acetaminophen. The separations were carried out in an analytical column packed with C-18 stationary phase and the mobile phase was

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A conducting polypyrrole film immobilized with PMo12O403- anion on a glassy carbon electrode was prepared by an electrochemical method. This kind of chemically modified electrode (CME) was prepared successfully by doping the polypyrrole film electrode wit

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrocatalytic oxidation of sulfhydryl compounds was effective on a copper hexacyanoferrate (CuHCF) film glassy carbon electrode, at a significantly reduced overpotential (0.55 to 0.65 V) and for a broader pH range (2.0 to 7.0). The electrocatalysis was

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the specific determination of cobalt based on reversed-phase liquid chromatography with amperometric detection via on-column complex formation has been developed. A water-soluble chelating agent, 1-(2-pyridylazo)-2-naphthol-6-sulphonic acid (PAN-6S), is added to the mobile phase and aqueous cobalt solutions are injected directly into the column to form in situ the cobalt-PAN-6S chelate, which is then separated from other metal PAN-6S chelates and subjected to reductive amperometric detection at a moderate potential of -0.3 V. Because the procedure eliminates the interference of oxygen and depresses the electrochemical reduction of the mobile phase-containing ligand PAN-6S, by virtue of the quasi:reversible electrode process of the cobalt-PAN-6S complex, a low detection limit of 0.06 ng can be readily obtained. Interference effects were examined for sixteen common metal species, and at a 5- to 8000-fold excess by mass no obvious interference was observed. The feasibility of the method as an approach to the specific analysis of cobalt in a hair sample has been demonstrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A glassy carbon electrode coated with an electrodeposited film of mixed-valent cobalt oxide/cyanocobaltate (Co-O/CN-Co) enabled hydrazine compounds to be catalytically oxidized at the greatly reduced overpotential and in a wide operational pH range (pH 2.0-7.0). Electrocatalytic activity at the Co-O/CN-Co modified electrode was evaluated with respect to solution pH, film thickness, supporting electrolyte ions, potential scan rate, operating potential, concentration dependence and other variables. The Co-O/CN-Co film electrode was completely compatible with a conventional reversed-phase liquid chromatographic (RP-LC) system. Practical RP-LC amperometric detection (RP-LCEC) of hydrazines was performed. A dynamic linear response range over three orders of magnitude and a detection limit at the pmol level were readily obtained. The Co-O/CN-CO film electrode exhibited excellent electrocatalytic stability in the flowing streams.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new liquid chromatography electrochemical (LCEC) scheme for glucose sensing has been developed on the basis of a Prussian Blue chemically modified electrode (CME) of novel construction and characterized in terms of various experimental parameters by the flow injection analysis (FIA) technique. Unique hydrodynamic voltammograms were obtained for the first time at the CME in the flow-through amperometric detection of glucose, and subsequently both anodic and cathodic peaks could be expected on monitoring the operating potential in the modest positive or negative region. The unique pH dependence on the CME response towards glucose makes it perfectly compatible with conventional reversed phase liquid chromatography systems. On the basis of these features, practical application in glucose LCEC detection has been effectively performed; a linear response range over three orders of magnitude and a detection limit of subpicomole level were readily obtained. The capability of the established LCEC mode in the direct sensing of urinary glucose has been demonstrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A vitamin B-12 chemically modified electrode (CME) was constructed by adsorption of vitamin B-12 onto a glassy carbon surface. The electrode catalyzes the electrooxidation of hydrazine compounds over a wide pH range. The electrocatalytic behavior of hydrazines is elucidated with respect to the CME preparation conditions, solution pH, operating potential, mobile phase flow rate, and other variables. When applied to liquid chromatographic detection of the analytes, the vitamin B-12 CME yielded a linear response range over 2 orders of magnitude, and detection limits at the picomole level. The vitamin B-12 CME offers acceptable catalytic stability in both batch and flow systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A copper-based chemically modified electrode (CME) has been constructed and characterized for flow-through amperometric detection of catechol, resorcinol, and hydroquinone. Novel potential dependence of the detector response was first obtained for these analytes at the Cu CME, where negative peaks together with positive ones were observed in one definite chromatogram using amperometric detection. Its advantages in chromatographic applications were demonstrated. From these observations it is proposed that the detector response was governed by formation of copper complexes with the solutes. A dynamic linear range over two orders of magnitude was obtained, when operating the detector at +0.10 V vs. SCE, from which ng detection limits were achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel Prussian blue chemically modified electrode (CME) was constructed and characterized for liquid chromatography electrochemical detection (LCEC) of catecholamines. Both anodic and cathodic peaks could be obtained by monitoring at constant applied potential at anodic and slightly cathodic potential ranges (0.3-0.7 and -0.2-0.1 V vs. SCE), respectively. When arranged in a series configuration, using the modified electrodes as generating and collecting detectors, extremely high effective collection efficiencies of 0.91 (for norepinephrine) and 0.58 (for dihydroxyphenylacetic acid) were achieved in dual-electrode LCEC for catecholamines; and a linear response range over 3 orders of magnitude and a detection limit of 10 pg were obtained with a downstream CME as the indicating detector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemically modified electrodes prepared by adsorbing prussian blue on a glassy carbon electrode are shown to catalyse the electro-oxidation of cysteine, N-acetylcysteine and glutathione in acidic media. The catalytic response is evaluated with respect to the potential scan rate, the solution pH, the concentration dependence, and other variables. Covering the electrode with Nafion(R) film improved the stability and reproducibility in liquid chromatography with electrochemical detection to the extent that repetitive sample injections produced relative standard deviations of less than 5% over several hours of operation. The limit of detection was 4 pmol for cysteine, 33 pmol for glutathione and 61 pmol for N-acetylcysteine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A copper-based chemically-modified electrode has been constructed and characterized by various experimental parameters in flow-through amperometric detection of carboxylic acids and phenolic acids. Novel hydrodynamic voltamperograms were first obtained in flow-through amperometric detection with the Cu-based CME and subsequently negative and positive peaks were observed in a single chromatogram. This unique and flexible potential dependence could be of great benefit in chromatographic speciation and quantification. These observations suggest that the detector response was governed by the complexation reaction of copper ions with the solutes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dispersion of alumina particles on a glassy-carbon surface serving as a modified electrode significantly enhances the amperometric detection of cysteine and glutathione following liquid chromatography. With an applied potential of 0.8 V vs. SCE, the detection limits were 1.2 ng for cysteine and 8 ng for glutathione and the electrode response was linear up to 600 ng for cysteine and 1.8-mu-g for glutathione. The modified electrode displayed high sensitivity and stability and was easy and inexpensive to prepare.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of chemically modified electrodes (CMEs) for liquid chromatography and flow-injection analysis is reviewed. Electrochemical detection with CMEs based on electrocatalysis, permselectivity, ion flow in redox films, and ion transfer across the water-solidified nitrobenzene interface is discussed in terms of improving the stability, selectivity, and scope of electrochemical detectors, and the detection of electroinactive substances. More than 90 references are included.