172 resultados para Li-Ion Battery
Resumo:
The micro-beam irradiation system, which focuses the beam down to micron order and precisely delivers a predefined number of ions to a predefined spot of micron order, is a powerful tool for radio-biology, radio-biomedicine and micromachining. The Institute of Modern Physics of Chinese Academy of Sciences is developing a heavy-ion microbeam irradiation system up to intermediate energy. Based on the intermediate and low energy beam provided by Heavy Ion Research Facility of Lanzhou, the micro-beam system takes the form of the magnetic focusing. The heavy-ion beam is conducted to the basement by a symmetrical achromatic system consisting of two vertical bending magnets and a quadrupole in between. Then a beam spot of micron order is formed by a magnetic triplet quadrupole of very high gradient. The sample can be irradiated either in vacuum or in the air. This system will be the first opening platform capable of providing heavy ion micro-beam, ranging from low (10MeV/u) to intermediate energy (100MeV/u), for irradiation experiment with positioning and counting accuracy. Target material may be biology cell, tissue or other non-biological materials. It will be a help for unveiling the essence of heavy-ion interaction with matter and also a new means for exploring the application of heavy-ion irradiation.
Resumo:
Treatment planning of heavy-ion radiotherapy involves predictive calculation of not only the physical dose but also the biological dose in a patient body. The goal in designing beam-modulating devices for heavy ion therapy is to achieve uniform biological effects across the spread-out Bragg peak (SOBP). To achieve this, a mathematical model of Bragg peak movement is presented. The parameters of this model have been resolved with Monte Carlo method. And a rotating wheel filter is designed basing on the velocity of the Bragg peak movement.
Resumo:
In this work, the neutron radiation field at Heavy Ion Research Facility in Lanzhou (HIRFL) was investigated. Total neutron yields, spectra and angular distributions in the bombardment of various thick targets by C-12 and O-18 ions with energies up to 75 MeV/u were obtained using the activation method. The neutron dose equivalent rates of 60 MeV/u O-18 on various thick targets at different angles were measured with a modified A-B remmeter. Our results are compared with those of other reports.
Resumo:
The aim of this study is to investigate the effects of different doses of 100 MeV/u carbon ions on sweet sorghum seeds in order to improve crop yields and their sugar content. After irradiation, seeds were germinated and grown to 30 days, and others were sown in the field. At the end of harvesting season all planted seeds were picked separately and M2 generations obtained. The differences among the treatments were examined using the RAPID procedure. In the study done by using 38 primers; according to the amplification results, the differences among the various doses treatment were shown.
Resumo:
The differential cross sections for elastic scattering products of F-17 on Pb-208 have been measured. The angular dispersion plots of ln(d sigma/d theta) versus theta(2) are obtained from the angular distribution of the elastic scattering differential cross sections. Systematical analysis on the angular dispersion for the available experimental data indicates that there is an angular dispersion turning angle at forward angular range within the grazing angle. This turning angle can be clarified as nuclear rainbow in classical deflection function. The exotic behaviour of the nuclear rainbow angle offers a new probe to investigate the halo and skin phenomena.
Resumo:
The neutron-rich nucleus Li-11 is separated by the radioactive ion beam line RIBLL at HIRFL from the breakup of 50MeV/u C-13 on Be target. The total reaction cross sections for Li-11 at energies range from 25 to 45MeV/u on Si target have been measured by using the transmission method. The experimental data at high and low energies can be fitted well by Glauber model using two Gauss density distribution. The matter radius of Li-11 was also deduced.
Resumo:
Basic research related to heavy-ion cancer therapy has been done at the Institute of Modern Physics (IMP), Chinese Academy of Sciences since 1995. Now a plan of clinical trial with heavy ions has been launched at IMP. First, superficially placed tumor treatment with heavy ions is expected in the therapy terminal at the Heavy Ion Research Facility in Lanzhou (HIRFL), where carbon ion beams with energy up to 100 MeV/u can be supplied. The shallow-seated tumor therapy terminal at HIRFL is equipped with a passive beam delivery system including two orthogonal dipole magnets, which continuously scan pencil beams laterally and generate a broad and uniform irradiation field, a motor-driven energy degrader and a multi-leaf collimator. Two different types of range modulator, ripple filter and ridge filter with which Guassian-shaped physical dose and uniform biological effective dose Bragg peaks can be shaped for therapeutic ion beams respectively, have been designed and manufactured. Therefore, two-dimensional and three-dimensional conformal irradiations to tumors can be performed with the passive beam delivery system at the earlier therapy terminal. Both the conformal irradiation methods have been verified experimentally and carbon-ion conformal irradiations to patients with superficially placed tumors have been carried out at HIRFL since November 2006.
Resumo:
A 320 kV high voltage (HV) platform has been constructed at Institute of Modern Physics (IMP) to satisfy the increasing requirements of experimental studies in some heavy ion associated directions. A high charge state all-permanent magnet ECRIS-LAPECR2 has been designed and fabricated to provide intense multiple charge state ion beams (such as 1000 e mu A O6+, 16.7 e mu A Ar14+, 24 e mu A Xe27+, etc.) for the HV platform. LAPECR2 has a dimension of 0 650 mm x 560 mm. The powerful 3D magnetic confinement to the ECR plasma and the optimum designed magnetic field for the operation at 14.5 GHz makes it possible to obtain very good performances from this source. After a brief introduction of the ECRIS and accelerator development at IMP, the conceptual design of LAPECR2 source is presented. The first test results of this all-permanent magnet ECRIS are given in this paper.
Resumo:
This study is aimed at observing the apoptosis and Bcl-2/Bax gene expression of mammalian cells following heavy-ion and X-ray irradiations. Exponentially growing human hepatoma SMMC-7721 cells cultured in vitro were irradiated with a C-12 ion beam of 50 MeV/u (corresponding to a LET value of 44.56 keV/mu m) from Heavy Ion Research Facility in Lanzhou (HIRFL) at doses varying from 0 to 3 Gy. The X-ray irradiation (8 MV) was performed in the therapy unit of the General Hospital of the Lanzhou Military Area. Survival fractions of irradiated cells at various doses were measured by means of MTT assay. Apoptotic cells after irradiation were analyzed with fluorescence microscope and flow cytometer (FCM). Immuno-histological assay were applied to detect the expression of Bcl-2/Bax genes in the irradiated cells. The survival fraction of SMMC-7721 cells decreased gradually (vs. control p<0.05) with increasing the dose of the carbon ion beam more obviously than X-ray irradiation, and the carbon ion irradiation efficiently induced cell apoptosis and significantly promoted the expression of Bax gene while Bcl-2 gene expression was restrained. High-LET heavy ion beam would induce cell apoptosis effectively than low-LET X-ray, and the apoptosis rate is correlated with the transcription of Bcl-2/Bax and the ratio of Bcl-2/Bax in human hepatoma SMMC-7721 cells after irradiation to heavy ion beam.
Resumo:
Since 1998, many experiments for metallic ion production have been done on LECR2 (Lanzhou ECR ion source NO.2), LECR3 (Lanzhou ECR ion source NO.3) and SECRAL (Superconductiong ECR ion source Advanced design in Lanzhou) at Institute of Modern Physics. The very heavy metallic ion beams such as those of uranium were also produced by the plasma sputtering method, and supplied for HIRFL (Heavy Ion Research Facility in Lanzhou) accelerators successfully. During the test, 11.5e mu AU(28+), 9e mu AU(24+) were obtained. Some ion beams of the metal having lower melting temperature such as Ni and Mg ion beams were produced by oven method on LECR3 too. The consumption rate was controlled to be lower for Mg-26 ion beams production, and the minimum consumption was about 0.3mg per hour. In this paper, the main experimental results are given. Some discussions are made for some experimental phenomena and results, and some conclusions are drawn.
Resumo:
The Lanzhou All Permanent magnet ECR ion source NO. 1 (LAPECR1) is the first all permanent magnet multiple ECRIS made in IMP. This ECRIS is running at 14.5GHz and can provide intense low charge state ion beams (varying from several to hundreds of e mu A) or medium charge state ion beams (varying from several to tens of e mu A). The size of source body is circle divide 102mmx296mm, the compactness and economical features enable the source suitable to be put on a HV platform or equipped by a small laboratory. This article gives the main parameters of the ion source.
Resumo:
In order to expand the solid angle for imaging of electrons in ion-atom collisions, we designed a complex Helmholtz coils composed of four single coils. Theoretical simulations were carried out to optimize the arrangement of the coils. The complex is constructed according to the theoretical analysis, and the magnetic fields were measured for interested regions. The measured results show that the relative uniformity of the magnetic fields is +/- 0.6%, which satisfies the requirements of collision experiments.
Resumo:
Single crystal sapphire (Al2O3) samples implanted with 110 keV He and irradiated at 320 K by Pb-208(27), ions with energy of 1.1 MeV/u to the fluences ranging from 1 X 10(12) to 5 X 10(14) ion/cm(2) and subsequently annealed at 600, 900 and 1100 K. The obtained PL spectra showed that emission peaks centred at 375, 390, 413, and 450 nm appeared in irradiated samples. The peak of 390 ran became very intense after 600 K annealing. The peak of 390 nm weakened and 510 nm peak started to build up at 900 K annealing, the peak of 390 nm vanished and 510 nm peak increased with the annealing temperature rising to 1100 K. Infrared spectra showed a broadening of the absorption band between 460 cm(-1), and 510 cm(-1) indicating strongly damaged regions being formed in the Al2O3 samples and position shift of the absorption band at 1000-1300 cm(-1) towards higher wavenumber after Pb irradiation.
Resumo:
The brain of the Kun-Ming strain mice were irradiated with 0.05 Gy of C-12(6+) ion or Co-60 gamma-ray as the pre-exposure dose, and were then irradiated with 2 Gy of 12C6+ ion or Co-60 gamma-ray as challenging irradiation dose at 4 h after per-exposure. Body weight and serum growth hormone (GH) concentration were measured at 35th day after irradiation. The results showed that irradiation of mouse brain with 2 Gy of C-12(6+) ion or Co-60 gamma-ray significantly diminished mouse body weight and level of serum GH. The relative biological effectiveness values of a 2 Gy dose of C-12(6+) ion calculated with respect to Co-60 gamma-ray were 1.47 and 1.34 for body weight and serum GH concentration, respectively. Pre-exposure with a low-dose (0.05 Gy) of C-12(6+) ion or Co-60 gamma-ray significantly alleviated reductions of mouse body weight and level of serum GH induced by a subsequent high-dose (2 Gy) irradiation. The data suggested that low-dose ionizing irradiation can induce adaptive hormetic responses to the harmful effects of pituitary by subsequent high-dose exposure.
Resumo:
Within the IBUU transport model, flipping of the symmetry potential in heavy-ion collisions is studied. It is found that there exist flipping of the symmetry potential in the isospin fractionation, the single neutron to proton ratio, the double neutron to proton ratio and the neutron-proton differential flow from lower to higher incident energies. The flipping of the symmetry potential results from the change of the relative magnitude of the hard and soft symmetry energies at lower and higher densities. Future observations of the flipped symmetry potential in experiment will help the study of the density-dependent symmetry energy.