113 resultados para Front-end receivers


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three distyrylbenzene (DSB) derivatives were vacuum-evaporated on a (001) surface of KBr. DSB derivative molecules formed nuclei by interaction between the electron donative methoxyl group and Br- ion of the substrate crystal and oriented their longitudinal axis obliquely to the substrate surface. The peak shift between the emission peaks of solution and film decreased depending on the number of substituent. This phenomenon was originated to reduction of molecular interaction between neighboring molecules by steric hindrance of end substituents. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensitive end-column amperometric detection has been successfully coupled to capillary electrophoresis for chiral separation of promethazine, with a carbon fiber microdisk electrode as working electrode. Baseline separation and sensitive detection were achieved under optimum conditions: 0.030 M Na2HPO4 and 0.015 M citric acid at pH = 2.50, 1.0 mM beta -CD, 10 kV separation voltage, and detection potential 1.10 V (vs Ag/AgCl). The numbers of theoretical plates were higher than 700000, and the detection limit was 5 x 10(-8) M. On-line treatment of the electrode has also been studied and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method was proposed for the separation of allopurinol (AP) and its active metabolite oxypurinol (OP) by capillary electrophoresis with end-column amperometric detection. A running buffer composed of 15 rum Na2HPO4/NaH2PO4 at a pH 9.55, electrokinetic injection 7 s at 5 kV, separation voltage at 15 kV and detection potential at 1.20 V were investigated to be the optimal condition for the separation. The method exhibited low detection Emit (S/N = 3) as 1 x 10(-8) mol/l for AP and OP, wide linearity range of 2 x 10(-7) to 1 x 10(-4) mol/l, 1 x 10(-7) to 1 x 10(-4) and high efficiency of 1.2 x 10(5) and 1.8 x 10(5) N/m for AP and OP, respectively. The potential application examined for the method was the determination of the spiked urine sample, which was proved to be sensitive and efficient. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Determination of aesculin (AL) and aesculetin (AT) by capillary electrophoresis with end-column amperometric detection using a 33 mu m microdisk carbon fiber electrode is described. The HDVs, the effect of pH, buffer concentration, injection voltage, injection time and separation voltage on the peak current response (i(p)) of the analytes and the number of theoretical plates (N) were studied. The method has high sensitivity and good reproducibility. Under the optimum condition - 10 mM, pH 9.00 phosphate buffer, 4 s at 9 kV injection, separation at 15 kV and +1.0 V as the detection potential - low detection limits (S/N = 3) of 0.06 and 0.3 mu M were obtained for AL and AT, respectively. The calibration curve was linear over three orders of magnitude. The relative standard deviations (n = 15) of peak current and migration time were 3.9% and 4.6%, and 0.96% and 0.75% for 15 consecutive injections of 5 mu M AL and AT, respectively. The use of this method for the separation and detection of the two compounds present in the traditional Chinese medicine and human urine samples is also reported. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

End-column amperometric detection of 6-mercaptopurine by capillary zone electrophoresis was described with high resolution and speed. The detection conditions were optimized and the electrochemical behavior was observed. Under the optimal conditions: detection potential of 1.2 V ( vs. Ag/AgCl), operating voltage of 15 kV, sample injection of 3 s at 15 kV and 10 mmol/l Na2HPO4 buffer, the detection limit for 6-MP was as low as 1 x 10(-7) mol/L and the linear range was from 5 x 10(-4) to 5 x 10(-6) mol/L with the relative coefficient of 0.995. The RSD of reproducibility for peak current and migration time was 2.5% and 1.2%, respectively. This method was utilized in assay real sample of human mine and bovine serum albumin containing 6-mercaptopurine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrochemical detection of five species of aromatic amines at a carbon fiber microdisk electrode after separation by capillary electrophoresis is described. Under the optimum conditions, the detection limit for 3,4-dihydroxybenzylamine, N,N-dimethylaniline, p-phenylenediamine, p-aminophenol and aniline sulfate was 0.9, 0.03, 0.075, 1.2 and 0.15 mu M (S/N = 3), respectively. The linear response range was 5-1000, 0.1-500, 0.5-500, 5-500 and 1-200 mu M, respectively The effect of the electrode position and buffer pH on the detection was also studied. This method is very simple, sensitive and stable for the detection of these compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and sensitive detection method for the determination of 5-fluorouracil(5-FU) in real samples such as human urine and bovine serum albumin (BSA) was described. A carbon fiber microdisk electrode was used to perform end-column amperometric detection in capillary zone electrophoresis. The detection limit was as low as 2.5x10(-7) M and the wider linear range for the concentration was between 5x10(-6) and 1x10(-4) M with a correlation coefficient of 0.995.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Promethazine and thioridazine were separated and detected by capillary electrophoresis with end-column amperometric detection. The influence of pH Value on oxidation potential, the peak current and the resolution were studied and the following conditions was selected: 0.03 M Na2HPO4 and 0.015 M citric acid at pH 3.0, detection potential at 1.10 V. The detection limits of these two substances were in the range of 10(-8) mol/l. The linear range spanned two to three orders of magnitude. This method was applied to the detection of promethazine and thioridazine spiked in urine. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of sulfadiazine (SDZ) and sulfamethoxazole (SMZ) is described. Under the optimum conditions, SDZ and SMZ were separated satisfactorily, and a highly sensitive and stable response was obtained at a potential of 1.1 V versus Ag/AgCl. Optimized end-column detection provides detection limits as low as 0.1 mu M for both compounds, which corresponds to 0.024 and 0.021 fmol with peak efficiencies of 394000 and 335000 theoretical plates for SDZ arid SMZ, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 12) of peak currents and migration times were 2.3 and 2.7%, and 0.8 and 1.3%, respectively, for the two compounds. The proposed method was applied to the analysis of tablets and human urine samples with satisfactory results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The plastic zone size and crack opening displacement of phenolphthalein polyether ketone (PEK-C) at various conditions were investigated. Both of them increase with increasing temperature (decreasing strain rate), i.e. yield stress steadily falls. Thus, the mechanism increasing the yield stress leads to increased constraint in the crack tip and a corresponding reduction in the crack opening displacement and the plastic deformation zone. The effect of the plastic deformation on the fracture toughness is also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative data on the crystallization kinetics of polymorphic polymers can be derived from the investigation of gross spherulitic morphology formed in isothermal conditions. Depending on distance between centers, and the time lag between their formation and relative growth rates, various types of boundary lines can be generated by the impinging of two spherical bodies whose radii increase linearly with time, In polymorphic polymers, different types of spherulites often develop simultaneously at different rates from sporadic or predetermined nuclei. In same cases, the so-called growth transformation, in which a nucleus of the fast growing specie is formed at the tip of an advancing lamella of the slower crystal form, provides an alternative mode of nucleation, It is shown that if only one event of growth transformation takes place at the front of a slow growing body, the fast growing spherulite swallows the parent one and the resultant shape of interspherulitic boundary is described by two symmetrical logarithmic spirals whose parameters can be extracted from micrographs taken at the end of crystallization. These concepts are applied to determine the radial growth rate of gamma form spherulites of polypivalolactone in a wide range of temperatures through analysis of the alpha/gamma interspherulitic profiles formed in isothermal conditions and direct measurement of the growth rate of the alpha counterparts at the same temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New copolyether sulfones containing 2,6-bis(p-oxo-benzylidene)cyclohexanone and 2,6-bis(o,p-dioxo-benzylidene)cyclohexanone moieties were prepared in the conventional literature manner by condensing the dipotassium salts of 2,6-bis(p-hydroxybenzylidene)cyclohexanone (III), 2,6-bis(o,p-dihydroxybenzylidene)-cyclohexanone (V), and 2,2-bis(p-hydroxyphenyl)propane (Bisphenol A, VII) with 4,4'-dichlorodiphenyl sulfone (VI), or by condensing the dipotassium salts of III and VII with a new benzylidene cyclohexanone sulfone macromer (X). Finally, the polycondensation reaction of sulfonyl bis(p-benzaldehydeoxo-p-phenylene) (IX) with cyclohexanone leads to an unsaturated copolymer (XVI). The resulting copolyether sulfones were confirmed by IR, H-1-NMR, viscometry, elemental analysis, thermooptical (TOA), x-ray, and thermogravimetric (TGA) measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chloro-terminated polysulfones with various molecular weights were modified with poly(ethylene oxide) and poly[(ethylene oxide)(propylene oxide)] macromers carrying alpha-hydroxyl and omega-allyl end groups via classical polycondensation reactions. The pr

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the correction of mode II strain energy release rate, G(II), of composite laminates measured with the end-notched flexure (ENF) specimen. A derivation is given of the expressions for compliance and strain energy release rate, in whic