284 resultados para FRESH EXTRACTION SITES
Resumo:
IEECAS SKLLQG
Resumo:
IEECAS SKLLQG
Resumo:
IEECAS SKLLQG
Resumo:
The extraction of protactinium with Aliquat 336 (methyl-tri-caprylyl ammonium chloride) in toluene, cyclohexane and chloroform from HCl, HNO3, H2SO4, HClO4, HF and mixed HCl-HF media was investigated by radioactive tracer technique. Distribution ratios of protactinium between the aqueous solution and the organic phase were determined as a function of shaking time, concentrations of acid in aqueous solution phase, extractant concentration and type of diluents in the organic phase. Aliquat 336 can almost quantitatively extract protactinium from strong HCl solution. At the same time, small amounts of HF in HCl solutions have a strong effect on Pa distribution.
Resumo:
In order to study the extraction pattern of protactinium in different types of extracting agents and compare the similarity of patterns of extraction with dubnium and thereby unraveling its chemistry, solvent extraction of protactinium(V) with methyl-iso-butyl carbinol (MIBC) and methyl-iso-butyl ketone (MIBK) was studied using Pa-233 as a radiotracer. The extraction efficiencies of Pa were determined as a function of shaking time, concentrations of mineral acids, and extractant concentrations using the two extractants. The results show that MIBK is more suitable for the extraction of protactinium than MIBC in benzene. Furthermore, the effect of the F anion is also discussed.
Resumo:
Solvent extraction of protactinium with tri-iso-octyl-amine (TIOA) in xylene, benzene, carbon tetrachloride and chloroform from HCl, HF, HNO3, HClO4 and H2SO4 media was studied using Pa-233 as a radiotracer. The extraction efficiencies of protactinium were determined as a function of shaking time, concentrations of mineral acids in aqueous phase, extractant concentrations and diluents in organic phase. The extraction mechanism was discussed. The results show that the extracted species in the organic phase is [(R3N-H)(n)Pa(OH)(x)Cl-y(5-x-y)].
Resumo:
The HIRFL (Heavy Ion Research Facility at Lanzhou) is a cyclotron complex. Its injector is a cector focusing cyclotron with K=69. Since the HIRFL started the operation in 1989, two bigger items of improvements have been finished, the species and intensity of the accelerated particles are increased obviously. But due to the lower extraction efficiency of the SFC, on one hand, a lot of beam lost, and on other hand, outgas from the surface of the electrostatic deflector is serious because of beam hitting. Even sometimes the vacuum press is destroyed. In the paper a new physical design is made to get an extraction system of the SFC with a higher efficiency.