121 resultados para Centric relation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single photon Sagnac interferometry as a probe to macroscopic quantum mechanics is considered at the theoretical level. For a freely moving macroscopic quantum mirror susceptible to radiation pressure force inside a Sagnac interferometer, a careful analysis of the input-output relation reveals that the particle spectrum readout at the bright and dark ports encode information concerning the noncommutativity of position and momentum of the macroscopic mirror. A feasible experimental scheme to probe the commutation relation of a macroscopic quantum mirror is outlined to explore the possible frontier between classical and quantum regimes. In the Appendix, the case of Michelson interferometry as a feasible probe is also sketched.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

在类氢离子能级相对论修正的基础上,依据屏蔽方法,给出了类氟体系基态电离能的一种表达式.依据原子序数9至20的元素类氟体系基态电离能的实验数据,使用Microcal Origin软件拟合出类氟体系非电离电子平均屏蔽系数与原子序数的函数关系,总结出类氟体系基态电离能遵从的关系式并进行了验证.推算了原子序数21至40的元素类氟离子的基态电离能.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The molecular structural parameters of indophenol and its derivatives were calculated by semi-empirical molecular orbital quantum chemical method,The relation between molecular structural parameters and formal potentials was analyzed by principal factor analysis and multiple Linear regression method. It was found that the formal potential of indophenols has a good relation with two-center electron exchange energy, E-ex (2), resonance energy of O-C bond, E-ex (C-1-O), and molecular ionization potential, I-p, among 19 moleclular structural parameters. The regression equation is E-0' = 1. 47 x 10 (-3) E-ex (two) - 5. 74 x 10 (-2) E-ex (C-1 - O) - 1. 41 x 10 (-2) I-p with RC = 0. 9999 and SD = 0. 00424. It was confirmed by the relation between structure parameters and formal potentials, and the thermodynamic stability of its intermediate products that the H (+) ionization is prior to the electron transfer step in the oxidation mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new amorphous comblike polymer(CBP) based on methylvinyl ether/maleic anhydride alternating copolymer backbone and on oligooxyethylene side chain was synthesized The dynamic mechanical properties of CBP-Li salt complexes showed that there were two glass transitions. There are two peaks in the plot of the ionic conductivity vs. Li salt concentration. The plot of Log sigma against 1/(T-To) shows an unusual dual VTF behavior when using sidechain glass transition temperature (T-beta) as To.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with the evaluation of the relative error (DELTA(A)) in estimated analyte concentrations originating from the wavelength positioning error in a sample scan when multicomponent analysis (MCA) techniques are used for correcting line interferences in inductively coupled plasma atomic emission spectrometry. In the theoretical part, a quantitative relation of DELTA(A) with the extent of line overlap, bandwidth and the magnitude of the positioning error is developed under the assumption of Gaussian line profiles. The measurements of eleven samples covering various typical line interferences showed that the calculated DELTA(A) generally agrees well with the experimental one. An expression of the true detection limit associated with MCA techniques was thus formulated. With MCA techniques, the determination of the analyte and interferent concentrations depend on each other while with conventional correction techniques, such as the three-point method, the estimate of interfering signals is independent of the analyte signals. Therefore. a given positioning error results in a larger DELTA(A) and hence a higher true detection limit in the case of MCA techniques than that in the case of conventional correction methods. although the latter could be a reasonable approximation of the former when the peak distance expressed in the effective width of the interfering line is larger than 0.4. In the light of the effect of wavelength positioning errors, MCA techniques have no advantages over conventional correction methods unless the former can bring an essential reduction ot the positioning error.