93 resultados para 2-DICHLOROETHANE INTERFACE


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The transfer behavior of tetramethylammonium cation (TMA~+) across the water/ nitrobenzene interface has been investigated by neopolarography including semiintegral (m), semidifferential (e), 1.5th order differential (e′) and 2.5 th order differential (e″) methods. The predicted dependences of peak height, peak potential and peak width on concentration and scan rate, etc have been discussed theoretically. The neopolarographic theory on the transfer of ions across the interface has been confirmed ...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On the basis of data collected in the Jiaozhou Bay in June and July 2003, the DIC distribution in seawater is studied, and an average air-sea flux of CO2 is estimated. The results show that the content of DIC inside the bay is markedly higher than outside the bay in June, but the content of DIC outside the bay is markedly higher than inside the bay in July. The trend of DIC distribution inside the bay is similar, viz. the content is the maximum in the northeast, then decreases gradually toward the west, and the content is the minimum in the west. The total trend of vertical distribution is to increase gradually from surface to bottom. This characteristic of DIC distribution is determined by Jiaozhou Bay hydrology and there is a close relation between DIC and particulate N,P. Average CO2 flux across the air-sea interface is 0.55 mol/(m(2.)a) in June and 0.72 mol/(m(2.)a) in July. Jiaozhou Bay is considered as a net annual source for atmospheric CO2 in June and July, and the total CO2 flux from seawater into atmosphere is about 740 t in June and 969 t in July.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An interface of chip-based capillary electrophoresis (CE)-inductively coupled plasma-atomic emission spectrometry (ICP-AES) that is based on cross-flow nebulization has been developed. A polydimethylsiloxane (PDMS) CE-chip with conventional cross channel layout was used. A stainless steel tube was placed orthogonal to the exit of the CE separation channel for cross flow nebulization. A supplementary flow of buffer solution at the channel exit was used to improve nebulization efficiency. Two capillaries were inserted into the CE chip near the inlet of the separation channel for sample and buffer solution injection. Syringe pumps were used to manipulate the flow rate and flow direction of the sample, buffer, and supplementary buffer solution. Peak broadening due to the shape (bulb and tube-shaped) and size of the spray chambers was studied. The smaller tube-shaped spray chamber was used because of smaller peak broadening effect due to aerosol transport. The nebulization and transport efficiency of the CE-ICP interface was approximately 10%. Ba2+ and Mg2+ ions were eluted from the CE-chip within 30 s. Resolution of the Ba2+ and Mg2+ peaks was 0.7 using the chip-based CE-ICP-AES system.