367 resultados para radioactive C-9-ion beam
Resumo:
The effects of 960 MeV carbon ion beam and 8 MeV X-ray irradiation on adventitious shoots from in vitro leaf explants of two different Saintpaulia ionahta (Mauve and Indikon) cultivars were studied with regard to tissue increase, shoots differentiation and morphology changes in the shoots. The experimental results showed that the survival fraction of shoot formation for the Mauve and Indikon irradiated with the carbon ion beam at 20 Gy were 0.715 and 0.600, respectively, while those for both the cultivars exposed to the Xray irradiation at the same dose were 1.000. Relative biological effectiveness (RBE) of Mauve with respect to X-ray was about two. Secondly, the percentage of regenerating explants with malformed shoots in all Mauve regenerating explants irradiated with carbon ion beam at 20 Gy accounted for 49.6%, while that irradiated with the same dose of X-ray irradiation was only 4.7%; as for Saintpatdia ionahta Indikon irradiated with 20 Gy carbon ion beam, the percentage was 43.3%, which was higher than that of X-ray irradiation. Last, many chlorophyll deficient and other varieties of mutants were obtained in this study. Based on the results above, it can be concluded that the effect of mutation induction by carbon ion beam irradiation on the leaf explants of Saintpaulia ionahta is better than that by X-ray irradiation; and the optimal mutagenic dose varies from 20 Gy to 25 Gy for carbon ion beam irradiation.
Resumo:
枯草芽孢杆菌BJ1是一种在真菌病害防治中发挥重要作用的生防因子,为进一步提高它的抑菌能力,获得生防效果更好的高效菌种,利用不同能量和剂量的12C6+对生防菌BJ1进行了离子辐照处理。研究结果表明:离子辐照生防菌BJ1的最适宜剂量为200~400 Gy,传能线密度(LET)为60 keV/μm;突变菌株的抑菌能力比BJ1提高了2%~21%;不仅防病效果比BJ1提高了17.48%,而且对植物具有更好的促生长作用。
Resumo:
采用束团在纵向相空间快速旋转的非绝热压缩方法研究了在兰州重离子加速器冷却储存环(HIRFL-CSR)上获取高能ns量级短脉冲重离子束的可行性,利用K-V包络方程对能量为250MeV/u、初始纵向束团长度为200ns、初始动量分散为5×10-4的238U72+离子束团的非绝热压缩过程进行了束流动力学模拟,给出了在束团压缩过程中束流相关参数的变化。结果表明,在CSR上可取得最短为16ns长度的238U72+离子束团,可满足用于高能量密度物理研究的50ns束团长度的要求。
Resumo:
Properties for the ground state of C-9 are studied in the relativistic continuum Hartree-Bogoliubov theory with the NLSH, NLLN and TM2 effective interactions. Pairing correlations are taken into account by a density-dependent delta-force with the pairing strength for protons determined by fitting either to the experimental binding energy or to the odd-even mass difference from the five-point formula. The effects of pairing correlations on the formation of proton halo in the ground state of C-9 are examined. The halo structure is shown to be formed by the partially occupied valence proton levels p(3/2) and p(1/2).
Resumo:
The energies and geometries of C-9 and LaC9+ clusters were calculated at HF, MP2 and DFT levels. For C-9, all theoretical levels show that the linear chain is the most stable structure. For LaC9+, two isomers were considered. In the first case La has two single bonds (A), while it forms a double bond in the second (B). Our results showed that in HF calculation, B is marginally more stable than A, while for MP2 and DFT, A is favored. Our results also revealed that there is not enough space for C-9 ring to accommodate lanthanum. Our conclusion agrees well with experiment.
Resumo:
The reactions of [Cp2Mo2(CO)4] (1) with 2,2'-dipyridyl disulphide (C5H4NS-)2, 8,8'-diquinolyl disulphide (C9H6NS-)2 and tetramethyl thiuram disulphide (Me2NC(S)S-)2 in toluene solution resulted in the cleavage of the Mo-Mo triple bond to yield molybdenum complexes [CpMo(CO)2(C5H4NS)] (2), [CpMo(CO)2(C9H6NS)] (3) and [CpMo(CO)2(S2CNMe2)] (4), respectively. The molecular structures of 2, 3 . O=PPh3 and 4 were determined by X-ray diffraction studies. Crystals of 2 are monoclinic, space group P2(1)/n, with Z = 4, in a unit cell of dimensions a = 6.448(1), b = 12.616(2), c = 14.772(2) angstrom, beta = 92.85(1)-degrees. The structure was refined to R = 0.028 and R(w) = 0.039 for 1357 observed reflections. Crystals of 3 . O=PPh3 are triclinic, space group P1BAR, with Z = 2, in a unit cell of dimensions a = 11.351(3), b = 13.409(3), c = 9.895(2) angstrom, alpha = 94.59(2), beta = 90.35(2), gamma = 78.07(2)-degrees. The structure was refined to R = 0.033 and R(w) = 0.037 for 3260 observed reflections. Crystals of 4 are monoclinic, space group P2(1)/a and Z = 4 with a = 12.468(5), b = 7.637(2), c = 13.135(4) angstrom, beta = 96.62(3). The structure was refined to R = 0.032 and R(w) = 0.042 for 1698 observed reflections. Each of complexes 2-4 contains a cyclopentadienyl ligand, a cis pair of carbonyls and a chelate ligand (S,N donor or S,S donor). All the compounds have distorted square-pyramid structures.
Resumo:
To determine whether adenovirus-mediated wild-type p53 transfer after radiotherapy could radiosensitize non-small-cell lung cancer (NSCLC) cells to subclinical-dose carbon-ion beam (C-beam), H1299 cells were exposed to a C-beam or -ray and then infected with 5 MOI of AdCMV-p53 or GFP (C-beam or -ray with p53 or GFP).Cell cycle was detected by flow cytometric analysis. The apoptosis was examined by a fluorescent microscope with DAPI staining. DNA fragmentation was monitored by the TUNEL assay. P53 mRNA was detected by reverse-transcriptase polymerase chain reaction. The expression of p53, MDM2, and p21 was monitored by Western blot. Survival fractions were determined by colony-forming assay. The percentages of G1-phase cells in C-beam with p53 increased by 8.2%–16.0%, 5.2%–7.0%, and 5.8%–18.9%, respectively, compared with C-beam only, -ray with p53, or p53 only. The accumulation of G2-phase cells in C-beam with p53 increased by 5.7%–8.9% and 8.8%–14.8%, compared with those in -ray with p53 or p53 only, respectively. The percentage of apoptosis for C-beam with p53 increased by 7.4%–19.1%, 5.8%–11.7%, and 5.2%–19.2%, respectively, compared with C-beam only, -ray with p53, or p53 only. The level of p53 mRNA in C-beam with p53 was significantly higher than that in p53 only. The expression level of p53 and p21 in C-beam with p53 was significantly higher than that in both C-beam with GFP and p53 only. The survival fractions for C-beam with p53 were significantly less than those for the other groups (p 0.05). The data suggested that AdCMV-p53 transfer could more efficiently radiosensitize H1299 cells to subclinical-dose C-beam irradiation through the restoration of p53 function.
Resumo:
The excited states in 22Mg have been investigated by the resonant elastic scattering of 21Na + p.A 4.0 MeV/nucleon 21Na beam was separated by the Center for Nuclear Study (CNS) radioactive ion beam separator (CRIB) and then used to bombard a thick (CH2)n target. The energy spectra of recoiled protons were measured at scattering angles of θc.m. ≈ 172◦, 146◦, and 134◦, respectively. A wide energy-range of excitation function in 22Mg (up to Ex ∼ 8.9 MeV) was obtained simultaneously with a thick-target method, and a state at 7.06 MeV was newly observed. The resonant parameters were deduced from an R-matrix analysis of the center-of-mass (c.m.) differential cross-section data with a SAMMY-M6-BETA code. The astrophysical resonant reaction rate for the 18Ne(α,p)21Na reactionwas recalculated based on the present parameters.Generally speaking,the present rates are much smaller than the previous ones.
Resumo:
The excited states in 22Mg have been investigated by the resonant elastic scattering of 21Na + p. A 4.0 MeV/nucleon 21Na beam was separated by the Center for Nuclear Study (CNS) radioactive ion beam separator (CRIB) and then used to bombard a thick (CH2)n target. The energy spectra of recoiled protons were measured at scattering angles of θc.m. ≈ 172◦ , 146◦, and 134◦, respectively. A wide energy-range of excitation function in 22Mg (up to Ex ∼ 8.9 MeV) was obtained simultaneously with a thick-target method, and a state at 7.06 MeV was newly observed. The resonant parameters were deduced from an R-matrix analysis of the center-of-mass (c.m.) differential cross-section data with a SAMMY-M6-BETA code. The astrophysical resonant reaction rate for the 18Ne(α,p)21Na reactionwas recalculated based on the present parameters. Generally speaking, the present rates are much smaller than the previous ones.
Resumo:
We briefly introduce the current status and progress in the field of radioactive ion beam physics and the study of super-heavy nuclei. Some important problems and research directions are outlined, such as the sub-barrier fusion reaction, the direct reaction at Fermi energy and high energies, the property of nuclei at drip-lines, new magic numbers and new collective motion modes for unstable nuclei and the synthesis and study of the super-heavy nuclei.
Resumo:
The micro-beam irradiation system, which focuses the beam down to micron order and precisely delivers a predefined number of ions to a predefined spot of micron order, is a powerful tool for radio-biology, radio-biomedicine and micromachining. The Institute of Modern Physics of Chinese Academy of Sciences is developing a heavy-ion microbeam irradiation system up to intermediate energy. Based on the intermediate and low energy beam provided by Heavy Ion Research Facility of Lanzhou, the micro-beam system takes the form of the magnetic focusing. The heavy-ion beam is conducted to the basement by a symmetrical achromatic system consisting of two vertical bending magnets and a quadrupole in between. Then a beam spot of micron order is formed by a magnetic triplet quadrupole of very high gradient. The sample can be irradiated either in vacuum or in the air. This system will be the first opening platform capable of providing heavy ion micro-beam, ranging from low (10MeV/u) to intermediate energy (100MeV/u), for irradiation experiment with positioning and counting accuracy. Target material may be biology cell, tissue or other non-biological materials. It will be a help for unveiling the essence of heavy-ion interaction with matter and also a new means for exploring the application of heavy-ion irradiation.
Resumo:
Within the framework of the pilot heavy-ion therapy facility at GSI equipped with an active beam delivery system of advanced raster scanning technique, a feasibility study on actively conformal heavy-ion irradiation to moving tumors has been experimentally conducted. Laterally, real-time corrections to the beam scanning parameters by the raster scanner, leading to an active beam tracing, compensate for the lateral motion of a target volume. Longitudinally, a mechanically driven wedge energy degrader (called depth scanner) is applied to adjust the beam energy so as to locate the high-dose Bragg peak of heavy ion beam to the slice under treatment for the moving target volume. It has been experimentally shown that compensations for lateral target motion by the raster scanner and longitudinal target shift by the depth scanner are feasible.
Resumo:
The foil-excited the spectrum of highly stripped titanium ions between 12-40 nm has been studied. Titanium ions of 80 and 120 MeV were provided by the HI-13 tandem accelerator at the China Institute of Atomic Energy. GIM-957 XUV-VUV monochromator was refocused to get highly-resolved spectra. Our experimental results and the published spectral data of laser-produced plasma show agreement in nearly all cases within +/- 0.03 nm. The spectra contained some weak or strong lines previously unclassified. These spectral lines mainly belong to 2s2p(2) for TiXVIII, 2p(3) for TiXVIII, 2s2p(3) for TiXVII, 2p(6)4p for Ti XII and 2p(6)3d for Ti XII transitions.